XH624E2S11
LX SERIES · source records, page 3
58 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for XH624E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 58 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 58 / 58 |
| EER2 · BTU/Wh | 11.7–12 | 58 / 58 |
| HSPF2 · BTU/Wh | 7.8–8.1 | 58 / 58 |
| Cooling capacity · BTU/h | 23,000–24,200 | 58 / 58 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 22,600–23,800 | 58 / 58 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 14,500–15,500 | 58 / 58 |
| Heating capacity at 5°F / −15°C · BTU/h | 11,900–12,800 | 58 / 58 |
| COP at 5°F / −15°C | 2.1–2.3 | 58 / 58 |
| Equipment / loop type | HP - Split System | 58 / 58 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 58 / 58 |
| Compressor staging | Two-stage | 58 / 58 |
| Connected capability | No | 58 / 58 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTF36B5ADS1+JMET08BS2N1AHRI reference: 217020328 | 15.20 | 8.00 | 11900 | 2.22 | EPA 4571299 → |
CTU36B5XDS1+JMET08BS2N1+TXVAHRI reference: 217020327 | 15.20 | 8.00 | 11900 | 2.22 | EPA 4571300 → |
CTM36B5ADS1+JMET12BS2N1AHRI reference: 217020318 | 15.20 | 8.00 | 12000 | 2.24 | EPA 4571301 → |
CTM36B5ADS1+JMET08BS2N1AHRI reference: 217020317 | 15.20 | 7.80 | 11900 | 2.22 | EPA 4571302 → |
CTM36B5ADS1+ furnace: RL18080B12MPS1AHRI reference: 217020316 | 15.20 | 8.10 | 12400 | 2.26 | EPA 4571303 → |
CTU36B5XDS1+TXV+ furnace: RG19060B12MPS1AHRI reference: 217020310 | 15.20 | 8.10 | 12500 | 2.24 | EPA 4571304 → |
CTF36B5ADS1+ furnace: RG19060B12MPS1AHRI reference: 217020309 | 15.20 | 8.10 | 12500 | 2.24 | EPA 4571305 → |
CTM36B5ADS1+ furnace: RG19060B12MPS1AHRI reference: 217020308 | 15.20 | 8.10 | 12800 | 2.22 | EPA 4571306 → |
CTM36B5ADS1+ furnace: RG19080B12MPS1AHRI reference: 217020306 | 15.20 | 7.80 | 12400 | 2.22 | EPA 4571307 → |
CTM36B5ADS2+ furnace: RL18080B12MPS1AHRI reference: 218528543 | 15.20 | 8.10 | 12400 | 2.26 | EPA 4647523 → |
CTM36B5ADS2+ furnace: RG19060B12MPS1AHRI reference: 218528533 | 15.20 | 8.10 | 12800 | 2.22 | EPA 4647533 → |
CTM36B5ADS2+ furnace: RG19080B12MPS1AHRI reference: 218528527 | 15.20 | 7.80 | 12400 | 2.22 | EPA 4647539 → |
CTU36B5XDS2+TXV+ furnace: RG19060B12MPS1AHRI reference: 218528351 | 15.20 | 8.10 | 12500 | 2.24 | EPA 4647661 → |
CTF36B5ADS2+ furnace: RG19060B12MPS1AHRI reference: 218528345 | 15.20 | 8.10 | 12500 | 2.24 | EPA 4647667 → |
CTM36B5ADS2+JME12B2SN2AHRI reference: 218638227 | 15.20 | 8.00 | 12000 | 2.24 | EPA 4664412 → |
CTU36B5XDS2+JME08B2SN2+TXVAHRI reference: 218638215 | 15.20 | 8.00 | 11900 | 2.22 | EPA 4664424 → |
CTF36B5ADS2+JME08B2SN2AHRI reference: 218638209 | 15.20 | 8.00 | 11900 | 2.22 | EPA 4664430 → |
CTM36B5ADS2+JME08B2SN2AHRI reference: 218638161 | 15.20 | 7.80 | 11900 | 2.22 | EPA 4664454 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →