XH624E2S11
LX SERIES · source records, page 2
58 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for XH624E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 58 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 58 / 58 |
| EER2 · BTU/Wh | 11.7–12 | 58 / 58 |
| HSPF2 · BTU/Wh | 7.8–8.1 | 58 / 58 |
| Cooling capacity · BTU/h | 23,000–24,200 | 58 / 58 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 22,600–23,800 | 58 / 58 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 14,500–15,500 | 58 / 58 |
| Heating capacity at 5°F / −15°C · BTU/h | 11,900–12,800 | 58 / 58 |
| COP at 5°F / −15°C | 2.1–2.3 | 58 / 58 |
| Equipment / loop type | HP - Split System | 58 / 58 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 58 / 58 |
| Compressor staging | Two-stage | 58 / 58 |
| Connected capability | No | 58 / 58 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTF30C5ACS1+JME12C2SN1AHRI reference: 217017003 | 16.00 | 7.80 | 12200 | 2.16 | EPA 4572054 → |
CTF30C5ACS1+JME16C2SN1AHRI reference: 217016999 | 16.00 | 7.80 | 12200 | 2.16 | EPA 4572057 → |
CTU30B5XCS1+JME12B2SN1+TXVAHRI reference: 217016919 | 16.00 | 7.80 | 12200 | 2.14 | EPA 4572078 → |
CTF30C5ACS1+JMET12CS2N1AHRI reference: 217016829 | 16.00 | 7.80 | 12300 | 2.14 | EPA 4572104 → |
CTF30C5ACS1+JMET16CS2N1AHRI reference: 217016816 | 16.00 | 7.80 | 12300 | 2.16 | EPA 4572107 → |
CTF30B5ACS1+JME12B2SN1AHRI reference: 217016794 | 16.00 | 7.80 | 12200 | 2.14 | EPA 4572114 → |
JHE30B5AD2SS2AHRI reference: 218457225 | 16.00 | 8.10 | 12100 | 2.26 | EPA 4639461 → |
JHE24B5AC2SS2AHRI reference: 218457219 | 16.00 | 8.00 | 12000 | 2.12 | EPA 4639467 → |
CTM36B5ADS2+ furnace: RL18100B12MPS1AHRI reference: 218528513 | 16.00 | 8.10 | 12500 | 2.26 | EPA 4647553 → |
CTM30B5ACS2+ furnace: RL18100B12MPS1AHRI reference: 218528475 | 16.00 | 7.80 | 12500 | 2.10 | EPA 4647575 → |
CTU36B5XDS2+TXV+ furnace: RL18100B12MPS1AHRI reference: 218528371 | 16.00 | 8.10 | 12500 | 2.28 | EPA 4647641 → |
CTF36B5ADS2+ furnace: RL18100B12MPS1AHRI reference: 218528361 | 16.00 | 8.10 | 12500 | 2.28 | EPA 4647651 → |
CTU36B5XDS2+TXV+ furnace: RL18080B12MPS1AHRI reference: 218528339 | 16.00 | 8.10 | 12400 | 2.28 | EPA 4647673 → |
CTF36B5ADS2+ furnace: RL18080B12MPS1AHRI reference: 218528329 | 16.00 | 8.10 | 12400 | 2.28 | EPA 4647683 → |
CTU36B5XDS2+TXV+ furnace: RG19080B12MPS1AHRI reference: 218528319 | 16.00 | 8.10 | 12400 | 2.24 | EPA 4647693 → |
CTF36B5ADS2+ furnace: RG19080B12MPS1AHRI reference: 218528313 | 16.00 | 8.10 | 12400 | 2.24 | EPA 4647699 → |
CTF30C5ACS2+JME12C2SN2AHRI reference: 218638221 | 16.00 | 7.80 | 12300 | 2.14 | EPA 4664418 → |
CTU36B5XDS2+JME12B2SN2+TXVAHRI reference: 218638185 | 16.00 | 8.00 | 12000 | 2.26 | EPA 4664436 → |
CTF36B5ADS2+JME12B2SN2AHRI reference: 218638179 | 16.00 | 8.00 | 12000 | 2.26 | EPA 4664442 → |
CTF30C5ACS2+JME16C2SN2AHRI reference: 218638173 | 16.00 | 7.80 | 12300 | 2.16 | EPA 4664448 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.