Goodman / AIR-SOURCE HEAT PUMP

GZV9SA241CA*

GZV9SA · source records, page 2

43 published source records · source checked Sep 21, 2026

SEER2 range16.9–21BTU/Wh
HSPF2 range8.5–10BTU/Wh
Cooling capacity23,000–24,000BTU/h

Each efficiency range summarizes published EPA records for GZV9SA241CA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 43 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh16.9–2143 / 43
EER2 · BTU/Wh11.7–12.243 / 43
HSPF2 · BTU/Wh8.5–1043 / 43
Cooling capacity · BTU/h23,000–24,00043 / 43
Heating capacity at 47°F / 8.3°C · BTU/h21,000–24,00043 / 43
Heating capacity at 17°F / −8.3°C · BTU/h21,000–24,00043 / 43
Heating capacity at 5°F / −15°C · BTU/h21,000–24,00043 / 43
COP at 5°F / −15°C2–2.443 / 43
Equipment / loop typeHP - Split System43 / 43
Refrigerant / source-reported GWPR-32 (GWP:675 | Lower GWP)43 / 43
Compressor stagingContinuously variable43 / 43
Connected capabilityYes43 / 43

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Manufacturer specifications

These values match the manufacturer’s exact model pattern GZV9SA241CA*. They describe the unit, separately from the EPA system ratings. For electrical work, the specification sheet requires checking the installed unit’s rating plate and its full instructions.

SpecificationValueManufacturer evidence
Equipment weight230 lbGZV9S — product specifications · page 3
Maximum overcurrent protection20 AGZV9S — product specifications · page 3
Minimum circuit ampacity17.4 AGZV9S — product specifications · page 3
Shipping weight265 lbGZV9S — product specifications · page 3
Voltage / phase at 60 Hz208-230/1 V / phaseGZV9S — product specifications · page 3

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CA*EA4830*3A*+MBVK16CP1X00A*Cold climate designationAHRI reference: 21669989219.209.20220002.00EPA 4520237
AHVE48CP0300A*Cold climate designationAHRI reference: 21669989019.209.20224002.10EPA 4520239
AHVE48CP1300A*Cold climate designationAHRI reference: 21669988919.209.20224002.10EPA 4520240
CHPEA4830*3A*+ furnace: G*VT960803BNA*Cold climate designationAHRI reference: 21797098018.209.00210002.00EPA 4518310
CHPEA4830*3A*+ furnace: G*VT960603BNA*Cold climate designationAHRI reference: 21797098218.209.00210002.00EPA 4518312
CHPEA4830*3A*+ furnace: G*VT800803B*A*Cold climate designationAHRI reference: 21797098418.209.00210002.00EPA 4518314
CHPEA4830*3A*+ furnace: G*VT800604B*A*Cold climate designationAHRI reference: 21797098618.209.00210002.00EPA 4518316
CHPEA4830*3A*+ furnace: G*VT800603B*A*Cold climate designationAHRI reference: 21797098818.209.00210002.00EPA 4518318
CHPEA4830*3A*+ furnace: G*VS800604BUA*Cold climate designationAHRI reference: 21797099218.209.00210002.00EPA 4518322
CHPEA4830*3A*+ furnace: G*VM970603BNA*Cold climate designationAHRI reference: 21797099418.209.00210002.00EPA 4518324
CHPEA4830*3A*+ furnace: G*VS960603BUA*Cold climate designationAHRI reference: 21797099018.209.00210002.00EPA 4518325
CHPEA4830*3A*+ furnace: G*VM970803BNA*Cold climate designationAHRI reference: 21797099618.209.00210002.00EPA 4518326
CHPEA4830*3A*+ furnace: G*VT960403BNA*Cold climate designationAHRI reference: 21797099818.209.00210002.00EPA 4518328
CHPEA4830*3A*+ furnace: G*VM970804CNA*Cold climate designationAHRI reference: 21669990918.209.00210002.00EPA 4520220
CHPEA4830*3A*+ furnace: G*VM971005CNA*Cold climate designationAHRI reference: 21669990718.209.00210002.00EPA 4520222
CHPEA4830*3A*+ furnace: G*VS800805CUA*Cold climate designationAHRI reference: 21669990518.209.00210002.00EPA 4520224
CHPEA4830*3A*+ furnace: G*VS960805CUA*Cold climate designationAHRI reference: 21669990318.209.00210002.00EPA 4520226
CHPEA4830*3A*+ furnace: G*VT800804C*A*Cold climate designationAHRI reference: 21669990118.209.00210002.00EPA 4520228
CHPEA4830*3A*+ furnace: G*VT800805C*A*Cold climate designationAHRI reference: 21669989918.209.00210002.00EPA 4520230
CHPEA4830*3A*+ furnace: G*VT801005C*A*Cold climate designationAHRI reference: 21669989718.209.00210002.00EPA 4520232

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

GZV9S — product specificationsManufacturer family specification sheet; only explicitly matched model patterns receive extracted values