Goodman / AIR-SOURCE HEAT PUMP

GZV9SA241CA*

GZV9SA

43 published source records · source checked Sep 21, 2026

SEER2 range16.9–21BTU/Wh
HSPF2 range8.5–10BTU/Wh
Cooling capacity23,000–24,000BTU/h

Each efficiency range summarizes published EPA records for GZV9SA241CA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 43 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh16.9–2143 / 43
EER2 · BTU/Wh11.7–12.243 / 43
HSPF2 · BTU/Wh8.5–1043 / 43
Cooling capacity · BTU/h23,000–24,00043 / 43
Heating capacity at 47°F / 8.3°C · BTU/h21,000–24,00043 / 43
Heating capacity at 17°F / −8.3°C · BTU/h21,000–24,00043 / 43
Heating capacity at 5°F / −15°C · BTU/h21,000–24,00043 / 43
COP at 5°F / −15°C2–2.443 / 43
Equipment / loop typeHP - Split System43 / 43
Refrigerant / source-reported GWPR-32 (GWP:675 | Lower GWP)43 / 43
Compressor stagingContinuously variable43 / 43
Connected capabilityYes43 / 43

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Manufacturer specifications

These values match the manufacturer’s exact model pattern GZV9SA241CA*. They describe the unit, separately from the EPA system ratings. For electrical work, the specification sheet requires checking the installed unit’s rating plate and its full instructions.

SpecificationValueManufacturer evidence
Equipment weight230 lbGZV9S — product specifications · page 3
Maximum overcurrent protection20 AGZV9S — product specifications · page 3
Minimum circuit ampacity17.4 AGZV9S — product specifications · page 3
Shipping weight265 lbGZV9S — product specifications · page 3
Voltage / phase at 60 Hz208-230/1 V / phaseGZV9S — product specifications · page 3

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CAHEA3630C3A*+MBVK16CH*X00A*Cold climate designationAHRI reference: 21669979521.0010.00240002.40EPA 4520242
CA*EA4830*3A*+ furnace: G*VT960803BNA*Cold climate designationAHRI reference: 21797098119.209.20220002.00EPA 4518311
CA*EA4830*3A*+ furnace: G*VT960603BNA*Cold climate designationAHRI reference: 21797098319.209.20220002.00EPA 4518313
CA*EA4830*3A*+ furnace: G*VT800803B*A*Cold climate designationAHRI reference: 21797098519.209.20220002.00EPA 4518315
CA*EA4830*3A*+ furnace: G*VT800604B*A*Cold climate designationAHRI reference: 21797098719.209.20220002.00EPA 4518317
CA*EA4830*3A*+ furnace: G*VT800603B*A*Cold climate designationAHRI reference: 21797098919.209.20220002.00EPA 4518319
CA*EA4830*3A*+ furnace: G*VS960603BUA*Cold climate designationAHRI reference: 21797099119.209.20220002.00EPA 4518320
CA*EA4830*3A*+ furnace: G*VS800604BUA*Cold climate designationAHRI reference: 21797099319.209.20220002.00EPA 4518321
CA*EA4830*3A*+ furnace: G*VM970803BNA*Cold climate designationAHRI reference: 21797099519.209.20220002.00EPA 4518323
CA*EA4830*3A*+ furnace: G*VM970603BNA*Cold climate designationAHRI reference: 21797099719.209.20220002.00EPA 4518327
CA*EA4830*3A*+ furnace: G*VT960403BNA*Cold climate designationAHRI reference: 21797100519.209.20220002.00EPA 4518335
CA*EA4830*3A*+ furnace: G*VM970804CNA*Cold climate designationAHRI reference: 21669991019.209.20220002.00EPA 4520219
CA*EA4830*3A*+ furnace: G*VM971005CNA*Cold climate designationAHRI reference: 21669990819.209.20220002.00EPA 4520221
CA*EA4830*3A*+ furnace: G*VS800805CUA*Cold climate designationAHRI reference: 21669990619.209.20220002.00EPA 4520223
CA*EA4830*3A*+ furnace: G*VS960805CUA*Cold climate designationAHRI reference: 21669990419.209.20220002.00EPA 4520225
CA*EA4830*3A*+ furnace: G*VT800804C*A*Cold climate designationAHRI reference: 21669990219.209.20220002.00EPA 4520227
CA*EA4830*3A*+ furnace: G*VT800805C*A*Cold climate designationAHRI reference: 21669990019.209.20220002.00EPA 4520229
CA*EA4830*3A*+ furnace: G*VT801005C*A*Cold climate designationAHRI reference: 21669989819.209.20220002.00EPA 4520231
CA*EA4830*3A*+ furnace: G*VT960804CNA*Cold climate designationAHRI reference: 21669989619.209.20220002.00EPA 4520233
CA*EA4830*3A*+ furnace: G*VT961005CNA*Cold climate designationAHRI reference: 21669989419.209.20220002.00EPA 4520235

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

GZV9S — product specificationsManufacturer family specification sheet; only explicitly matched model patterns receive extracted values

Collection method, revision history and known limitations →