GZV7SA4810A*
GZV7SA · source records, page 2
62 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for GZV7SA4810A*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 62 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 16.2–17.5 | 62 / 62 |
| EER2 · BTU/Wh | 10 | 62 / 62 |
| HSPF2 · BTU/Wh | 8.5–8.8 | 62 / 62 |
| Cooling capacity · BTU/h | 45,500–46,500 | 62 / 62 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 46,000–47,500 | 62 / 62 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 28,400–29,000 | 62 / 62 |
| Heating capacity at 5°F / −15°C · BTU/h | 33,600 | 62 / 62 |
| COP at 5°F / −15°C | 2 | 62 / 62 |
| Equipment / loop type | HP - Split System | 62 / 62 |
| Refrigerant / source-reported GWP | R-32 (GWP:675 | Lower GWP) | 62 / 62 |
| Compressor staging | Continuously variable | 62 / 62 |
| Connected capability | No | 62 / 62 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Manufacturer specifications
These values match the manufacturer’s exact model pattern GZV7SA4810A*. They describe the unit, separately from the EPA system ratings. For electrical work, the specification sheet requires checking the installed unit’s rating plate and its full instructions.
| Specification | Value | Manufacturer evidence |
|---|---|---|
| Equipment weight | 179 lb | GZV7S — product specifications · page 3 ↗ |
| Maximum overcurrent protection | 40 A | GZV7S — product specifications · page 3 ↗ |
| Minimum circuit ampacity | 37.5 A | GZV7S — product specifications · page 3 ↗ |
| Shipping weight | 198 lb | GZV7S — product specifications · page 3 ↗ |
| Voltage / phase at 60 Hz | 208-230/1 V / phase | GZV7S — product specifications · page 3 ↗ |
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CHPEA6030*3A*+ furnace: G*VT800804C*A*Cold climate designationAHRI reference: 215434453 | 16.50 | 8.50 | 33600 | 2.00 | EPA 3625171 → |
CHPEA6030*3A*+ furnace: G*VT800805C*A*Cold climate designationAHRI reference: 215434454 | 16.50 | 8.50 | 33600 | 2.00 | EPA 3625172 → |
CHPEA6030*3A*+ furnace: G*VT801005C*A*Cold climate designationAHRI reference: 215434455 | 16.50 | 8.50 | 33600 | 2.00 | EPA 3625173 → |
CHPEA6030*3A*+ furnace: G*VT961005DNA*Cold climate designationAHRI reference: 215434462 | 16.50 | 8.50 | 33600 | 2.00 | EPA 3625187 → |
CHPEA6030*3A*+ furnace: G*VM971205DNA*Cold climate designationAHRI reference: 215434464 | 16.50 | 8.50 | 33600 | 2.00 | EPA 3625188 → |
CHPEA6030*3A*+ furnace: G*VT961205DNA*Cold climate designationAHRI reference: 215434463 | 16.50 | 8.50 | 33600 | 2.00 | EPA 3625189 → |
CA*EA6030*3A*+ furnace: G*VS800805CUA*Cold climate designationAHRI reference: 215434426 | 16.50 | 8.80 | 33600 | 2.00 | EPA 3625354 → |
CA*EA6030*3A*+ furnace: G*VT800804C*A*Cold climate designationAHRI reference: 215434427 | 16.50 | 8.80 | 33600 | 2.00 | EPA 3625355 → |
CA*EA6030*3A*+ furnace: G*VT800805C*A*Cold climate designationAHRI reference: 215434428 | 16.50 | 8.80 | 33600 | 2.00 | EPA 3625356 → |
CA*EA6030*3A*+ furnace: G*VT801005C*A*Cold climate designationAHRI reference: 215434429 | 16.50 | 8.80 | 33600 | 2.00 | EPA 3625357 → |
CA*EA6030*3A*+ furnace: G*VT961005DNA*Cold climate designationAHRI reference: 215434436 | 16.50 | 8.80 | 33600 | 2.00 | EPA 3625364 → |
CA*EA6030*3A*+ furnace: G*VT961205DNA*Cold climate designationAHRI reference: 215434437 | 16.50 | 8.80 | 33600 | 2.00 | EPA 3625365 → |
CA*EA6030*3A*+ furnace: G*VM971205DNA*Cold climate designationAHRI reference: 215434438 | 16.50 | 8.80 | 33600 | 2.00 | EPA 3625366 → |
CHPEA4830*3A*+ furnace: G*VS800805CUA*Cold climate designationAHRI reference: 215434439 | 16.50 | 8.50 | 33600 | 2.00 | EPA 3625367 → |
CHPEA4830*3A*+ furnace: G*VT800804C*A*Cold climate designationAHRI reference: 215434440 | 16.50 | 8.50 | 33600 | 2.00 | EPA 3625368 → |
CHPEA4830*3A*+ furnace: G*VT800805C*A*Cold climate designationAHRI reference: 215434441 | 16.50 | 8.50 | 33600 | 2.00 | EPA 3625369 → |
CHPEA4830*3A*+ furnace: G*VT801005C*A*Cold climate designationAHRI reference: 215434442 | 16.50 | 8.50 | 33600 | 2.00 | EPA 3625370 → |
CHPEA4830*3A*+ furnace: G*VT961005DNA*Cold climate designationAHRI reference: 215434449 | 16.50 | 8.50 | 33600 | 2.00 | EPA 3625377 → |
CA*EA6030*3A*+ furnace: G*VC961205DNB*Cold climate designationAHRI reference: 215488115 | 16.50 | 8.80 | 33600 | 2.00 | EPA 3628254 → |
CHPEA4830*3A*+ furnace: G*VC961205DNB*Cold climate designationAHRI reference: 215488125 | 16.50 | 8.50 | 33600 | 2.00 | EPA 3628264 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
GZV7S — product specifications ↗ — Manufacturer family specification sheet; only explicitly matched model patterns receive extracted values
Collection method, revision history and known limitations →