Goodman / AIR-SOURCE HEAT PUMP

GZV7SA4810A*

GZV7SA

62 published source records · source checked Sep 21, 2026

SEER2 range16.2–17.5BTU/Wh
HSPF2 range8.5–8.8BTU/Wh
Cooling capacity45,500–46,500BTU/h

Each efficiency range summarizes published EPA records for GZV7SA4810A*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 62 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh16.2–17.562 / 62
EER2 · BTU/Wh1062 / 62
HSPF2 · BTU/Wh8.5–8.862 / 62
Cooling capacity · BTU/h45,500–46,50062 / 62
Heating capacity at 47°F / 8.3°C · BTU/h46,000–47,50062 / 62
Heating capacity at 17°F / −8.3°C · BTU/h28,400–29,00062 / 62
Heating capacity at 5°F / −15°C · BTU/h33,60062 / 62
COP at 5°F / −15°C262 / 62
Equipment / loop typeHP - Split System62 / 62
Refrigerant / source-reported GWPR-32 (GWP:675 | Lower GWP)62 / 62
Compressor stagingContinuously variable62 / 62
Connected capabilityNo62 / 62

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Manufacturer specifications

These values match the manufacturer’s exact model pattern GZV7SA4810A*. They describe the unit, separately from the EPA system ratings. For electrical work, the specification sheet requires checking the installed unit’s rating plate and its full instructions.

SpecificationValueManufacturer evidence
Equipment weight179 lbGZV7S — product specifications · page 3
Maximum overcurrent protection40 AGZV7S — product specifications · page 3
Minimum circuit ampacity37.5 AGZV7S — product specifications · page 3
Shipping weight198 lbGZV7S — product specifications · page 3
Voltage / phase at 60 Hz208-230/1 V / phaseGZV7S — product specifications · page 3

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
AHVE60DP1300A*Cold climate designationAHRI reference: 21542919917.508.80336002.00EPA 3625030
AHVE60DP0300A*Cold climate designationAHRI reference: 21542975217.508.80336002.00EPA 3625072
CA*EA6030*3A*+MBVK20DP1X00A*Cold climate designationAHRI reference: 21543396017.508.80336002.00EPA 3625250
CHPEA4830*3A*+MBVK20DP1X00A*Cold climate designationAHRI reference: 21543396217.508.50336002.00EPA 3625252
CHPEA6030*3A*+MBVK20DP1X00A*Cold climate designationAHRI reference: 21543396417.508.50336002.00EPA 3625254
CA*EA6030*3A*+MBVK20DP0X00A*Cold climate designationAHRI reference: 21758933917.508.80336002.00EPA 4497776
CHPEA4830*3A*+MBVK20DP0X00A*Cold climate designationAHRI reference: 21758934117.508.50336002.00EPA 4497777
CHPEA6030*3A*+MBVK20DP0X00A*Cold climate designationAHRI reference: 21758934317.508.50336002.00EPA 4497778
CHPEA6030*3A*+ furnace: G*VT800805D*A*Cold climate designationAHRI reference: 21543446117.008.50336002.00EPA 3625179
CA*EA6030*3A*+MBVK16CP1X00A*Cold climate designationAHRI reference: 21543395917.008.80336002.00EPA 3625249
CHPEA4830*3A*+MBVK16CP1X00A*Cold climate designationAHRI reference: 21543396117.008.50336002.00EPA 3625251
CHPEA6030*3A*+MBVK16CP1X00A*Cold climate designationAHRI reference: 21543396317.008.50336002.00EPA 3625253
CA*EA6030*3A*+ furnace: G*VT800805D*A*Cold climate designationAHRI reference: 21543443517.008.80336002.00EPA 3625363
CHPEA4830*3A*+ furnace: G*VT800805D*A*Cold climate designationAHRI reference: 21543444817.008.50336002.00EPA 3625376
CA*EA6030*3A*+MBVK16CP0X00A*Cold climate designationAHRI reference: 21758933817.008.80336002.00EPA 4497775
CHPEA4830*3A*+MBVK16CP0X00A*Cold climate designationAHRI reference: 21758934017.008.50336002.00EPA 4497779
CHPEA6030*3A*+MBVK16CP0X00A*Cold climate designationAHRI reference: 21758934217.008.50336002.00EPA 4497780
CHPEA4830*3A*+ furnace: G*VT961205DNA*Cold climate designationAHRI reference: 21543445016.508.50336002.00EPA 3625168
CHPEA4830*3A*+ furnace: G*VM971205DNA*Cold climate designationAHRI reference: 21543445116.508.50336002.00EPA 3625169
CHPEA6030*3A*+ furnace: G*VS800805CUA*Cold climate designationAHRI reference: 21543445216.508.50336002.00EPA 3625170

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

GZV7S — product specificationsManufacturer family specification sheet; only explicitly matched model patterns receive extracted values