GZV7SA3610A*
GZV7SA · source records, page 2
69 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for GZV7SA3610A*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 69 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–19 | 69 / 69 |
| EER2 · BTU/Wh | 10–10.5 | 69 / 69 |
| HSPF2 · BTU/Wh | 8.1–8.8 | 69 / 69 |
| Cooling capacity · BTU/h | 34,000–35,000 | 69 / 69 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 34,800–35,000 | 69 / 69 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 22,000 | 69 / 69 |
| Heating capacity at 5°F / −15°C · BTU/h | 28,000–29,000 | 69 / 69 |
| COP at 5°F / −15°C | 2 | 69 / 69 |
| Equipment / loop type | HP - Split System | 69 / 69 |
| Refrigerant / source-reported GWP | R-32 (GWP:675 | Lower GWP) | 69 / 69 |
| Compressor staging | Continuously variable | 69 / 69 |
| Connected capability | No · Yes | 69 / 69 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Manufacturer specifications
These values match the manufacturer’s exact model pattern GZV7SA3610A*. They describe the unit, separately from the EPA system ratings. For electrical work, the specification sheet requires checking the installed unit’s rating plate and its full instructions.
| Specification | Value | Manufacturer evidence |
|---|---|---|
| Equipment weight | 168 lb | GZV7S — product specifications · page 3 ↗ |
| Maximum overcurrent protection | 35 A | GZV7S — product specifications · page 3 ↗ |
| Minimum circuit ampacity | 31.8 A | GZV7S — product specifications · page 3 ↗ |
| Shipping weight | 185 lb | GZV7S — product specifications · page 3 ↗ |
| Voltage / phase at 60 Hz | 208-230/1 V / phase | GZV7S — product specifications · page 3 ↗ |
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CA*EA4830*3A*+ furnace: G*VT961205DNA*Cold climate designationAHRI reference: 215434199 | 18.50 | 8.50 | 28400 | 2.00 | EPA 3625487 → |
CA*EA4830*3A*+ furnace: G*VT961005DNA*Cold climate designationAHRI reference: 215434200 | 18.50 | 8.50 | 28400 | 2.00 | EPA 3625488 → |
CA*EA4830*3A*+ furnace: G*VT961005CNA*Cold climate designationAHRI reference: 215434201 | 18.50 | 8.50 | 28400 | 2.00 | EPA 3625489 → |
CA*EA4830*3A*+ furnace: G*VT960804CNA*Cold climate designationAHRI reference: 215434202 | 18.50 | 8.50 | 28400 | 2.00 | EPA 3625490 → |
CA*EA4830*3A*+ furnace: G*VT801005C*A*Cold climate designationAHRI reference: 215434203 | 18.50 | 8.50 | 28400 | 2.00 | EPA 3625491 → |
CA*EA4830*3A*+ furnace: G*VT800805D*A*Cold climate designationAHRI reference: 215434204 | 18.50 | 8.50 | 28400 | 2.00 | EPA 3625492 → |
CA*EA4830*3A*+ furnace: G*VT800805C*A*Cold climate designationAHRI reference: 215434205 | 18.50 | 8.50 | 28400 | 2.00 | EPA 3625493 → |
CA*EA4830*3A*+ furnace: G*VT800804C*A*Cold climate designationAHRI reference: 215434206 | 18.50 | 8.50 | 28400 | 2.00 | EPA 3625494 → |
CA*EA4830*3A*+ furnace: G*VS960805CUA*Cold climate designationAHRI reference: 215434207 | 18.50 | 8.50 | 28400 | 2.00 | EPA 3625495 → |
CA*EA4830*3A*+ furnace: G*VS800805CUA*Cold climate designationAHRI reference: 215434208 | 18.50 | 8.50 | 28400 | 2.00 | EPA 3625496 → |
CA*EA4830*3A*+ furnace: G*VM971205DNA*Cold climate designationAHRI reference: 215434209 | 18.50 | 8.50 | 28400 | 2.00 | EPA 3625497 → |
CA*EA4830*3A*+ furnace: G*VM971005CNA*Cold climate designationAHRI reference: 215434210 | 18.50 | 8.50 | 28400 | 2.00 | EPA 3625498 → |
CA*EA4830*3A*+ furnace: G*VM970804CNA*Cold climate designationAHRI reference: 215434211 | 18.50 | 8.50 | 28400 | 2.00 | EPA 3625499 → |
CA*EA6030*3A*+ furnace: G*VT801005C*A*Cold climate designationAHRI reference: 215434212 | 18.50 | 8.50 | 28400 | 2.00 | EPA 3625500 → |
CA*EA6030*3A*+ furnace: G*VT800805D*A*Cold climate designationAHRI reference: 215434213 | 18.50 | 8.50 | 28400 | 2.00 | EPA 3625501 → |
CA*EA6030*3A*+ furnace: G*VT800805C*A*Cold climate designationAHRI reference: 215434214 | 18.50 | 8.50 | 28400 | 2.00 | EPA 3625502 → |
CA*EA6030*3A*+ furnace: G*VT800804C*A*Cold climate designationAHRI reference: 215434215 | 18.50 | 8.50 | 28400 | 2.00 | EPA 3625503 → |
CA*EA6030*3A*+ furnace: G*VS800805CUA*Cold climate designationAHRI reference: 215434217 | 18.50 | 8.50 | 28400 | 2.00 | EPA 3625505 → |
CHPEA4830*3A*+ furnace: G*VT961205DNA*Cold climate designationAHRI reference: 215434218 | 18.50 | 8.10 | 28400 | 2.00 | EPA 3625506 → |
CHPEA4830*3A*+ furnace: G*VT961005DNA*Cold climate designationAHRI reference: 215434219 | 18.50 | 8.10 | 28400 | 2.00 | EPA 3625507 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
GZV7S — product specifications ↗ — Manufacturer family specification sheet; only explicitly matched model patterns receive extracted values
Collection method, revision history and known limitations →