Goodman / AIR-SOURCE HEAT PUMP

GZV7SA3610A*

GZV7SA

69 published source records · source checked Sep 21, 2026

SEER2 range15.2–19BTU/Wh
HSPF2 range8.1–8.8BTU/Wh
Cooling capacity34,000–35,000BTU/h

Each efficiency range summarizes published EPA records for GZV7SA3610A*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 69 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–1969 / 69
EER2 · BTU/Wh10–10.569 / 69
HSPF2 · BTU/Wh8.1–8.869 / 69
Cooling capacity · BTU/h34,000–35,00069 / 69
Heating capacity at 47°F / 8.3°C · BTU/h34,800–35,00069 / 69
Heating capacity at 17°F / −8.3°C · BTU/h22,00069 / 69
Heating capacity at 5°F / −15°C · BTU/h28,000–29,00069 / 69
COP at 5°F / −15°C269 / 69
Equipment / loop typeHP - Split System69 / 69
Refrigerant / source-reported GWPR-32 (GWP:675 | Lower GWP)69 / 69
Compressor stagingContinuously variable69 / 69
Connected capabilityNo · Yes69 / 69

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Manufacturer specifications

These values match the manufacturer’s exact model pattern GZV7SA3610A*. They describe the unit, separately from the EPA system ratings. For electrical work, the specification sheet requires checking the installed unit’s rating plate and its full instructions.

SpecificationValueManufacturer evidence
Equipment weight168 lbGZV7S — product specifications · page 3
Maximum overcurrent protection35 AGZV7S — product specifications · page 3
Minimum circuit ampacity31.8 AGZV7S — product specifications · page 3
Shipping weight185 lbGZV7S — product specifications · page 3
Voltage / phase at 60 Hz208-230/1 V / phaseGZV7S — product specifications · page 3

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
AHVE48DP1300A*Cold climate designationAHRI reference: 21542919719.008.80290002.00EPA 3625028
AHVE48DP0300A*Cold climate designationAHRI reference: 21542974219.008.80290002.00EPA 3625062
AHVE60DP1300A*Cold climate designationAHRI reference: 21542974719.008.50284002.00EPA 3625067
AHVE60DP0300A*Cold climate designationAHRI reference: 21542974819.008.50284002.00EPA 3625068
CA*EA4830*3A*+MBVK20DP1X00A*Cold climate designationAHRI reference: 21543392319.008.50284002.00EPA 3625213
CA*EA4830*3A*+MBVK16CP1X00A*Cold climate designationAHRI reference: 21543392419.008.50284002.00EPA 3625214
CA*EA6030*3A*+MBVK20DP1X00A*Cold climate designationAHRI reference: 21543392519.008.50284002.00EPA 3625215
CA*EA6030*3A*+MBVK16CP1X00A*Cold climate designationAHRI reference: 21543392619.008.50284002.00EPA 3625216
CHPEA4830*3A*+MBVK20DP1X00A*Cold climate designationAHRI reference: 21543392719.008.10284002.00EPA 3625217
CHPEA4830*3A*+MBVK16CP1X00A*Cold climate designationAHRI reference: 21543392819.008.10284002.00EPA 3625218
CA*EA4830*3A*+MBVK20DP0X00A*Cold climate designationAHRI reference: 21758930219.008.50284002.00EPA 4497739
CA*EA4830*3A*+MBVK16CP0X00A*Cold climate designationAHRI reference: 21758930319.008.50284002.00EPA 4497740
CA*EA6030*3A*+MBVK20DP0X00A*Cold climate designationAHRI reference: 21758930419.008.50284002.00EPA 4497741
CA*EA6030*3A*+MBVK16CP0X00A*Cold climate designationAHRI reference: 21758930519.008.50284002.00EPA 4497742
CHPEA4830*3A*+MBVK20DP0X00A*Cold climate designationAHRI reference: 21758930619.008.10284002.00EPA 4497743
CHPEA4830*3A*+MBVK16CP0X00A*Cold climate designationAHRI reference: 21758930719.008.10284002.00EPA 4497744
AHVE42CP1300A*Cold climate designationAHRI reference: 21542974318.508.50284002.00EPA 3625063
AHVE42CP0300A*Cold climate designationAHRI reference: 21542974418.508.50284002.00EPA 3625064
AHVE48CP1300A*Cold climate designationAHRI reference: 21542974518.508.50284002.00EPA 3625065
AHVE48CP0300A*Cold climate designationAHRI reference: 21542974618.508.50284002.00EPA 3625066

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

GZV7S — product specificationsManufacturer family specification sheet; only explicitly matched model patterns receive extracted values

Collection method, revision history and known limitations →