GE / AIR-SOURCE HEAT PUMP

NS22H36MA4-**A

NS22H SERIES · source records, page 2

73 published source records · source checked Sep 21, 2026

SEER2 range17.5–20.5BTU/Wh
HSPF2 range8.5–9BTU/Wh
Cooling capacity34,000–36,000BTU/h

Each efficiency range summarizes published EPA records for NS22H36MA4-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 73 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh17.5–20.573 / 73
EER2 · BTU/Wh11.7–1273 / 73
HSPF2 · BTU/Wh8.5–973 / 73
Cooling capacity · BTU/h34,000–36,00073 / 73
Heating capacity at 47°F / 8.3°C · BTU/h32,800–35,00073 / 73
Heating capacity at 17°F / −8.3°C · BTU/h21,800–23,00073 / 73
Heating capacity at 5°F / −15°C · BTU/h17,800–18,60073 / 73
COP at 5°F / −15°C2.02–2.373 / 73
Equipment / loop typeHP - Split System73 / 73
Refrigerant / source-reported GWPR-410A (GWP:2088)73 / 73
Compressor stagingContinuously variable73 / 73
Connected capabilityNo73 / 73

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
NCHC36CT4+TDR+ furnace: NF96U110V5CAHRI reference: 21240385420.008.50180002.04EPA 2472042
NCUC48CT4+TDR+ furnace: NF97U090M5CAHRI reference: 21240390220.008.80183002.22EPA 2472073
NCUC36BT4+TDR+ furnace: NF97X060V3BAHRI reference: 21240388720.008.50180002.12EPA 2472233
NCUU48CP4+TDR+TXV+ furnace: NF96U090V5CAHRI reference: 21240393220.008.80182002.22EPA 2472353
NCUU36BP4+TDR+TXV+ furnace: NF97X040V3BAHRI reference: 21240392020.008.50180002.12EPA 2472371
NCUU36BP4+TDR+TXV+ furnace: NF97U070M3BAHRI reference: 21240391920.008.50180002.12EPA 2472376
NCUC48CT4+TDR+ furnace: NF97X080V5CAHRI reference: 21240390520.008.80184002.22EPA 2472394
NCUU48CP4+TDR+TXV+ furnace: NF96U090V3CAHRI reference: 21240393120.008.80183002.22EPA 2472455
NCUC48CT4+TDR+ furnace: NF97U090M3CAHRI reference: 21240390020.008.80183002.22EPA 2472508
NCUC36BT4+TDR+ furnace: NF97X040V3BAHRI reference: 21240388620.008.50180002.12EPA 2472547
NCUU48CP4+TDR+TXV+ furnace: NF97U090M5CAHRI reference: 21240393620.008.80183002.22EPA 2472549
NCHC36CT4+TDR+ furnace: NF96U090V3CAHRI reference: 21240385220.008.50181002.02EPA 2472590
NCUC30BT4+TDR+ furnace: NF97X040V3BAHRI reference: 21240387819.508.50180002.12EPA 2471180
NCHC42CT4+TDR+ furnace: NF96U110V5CAHRI reference: 21240386519.508.70181002.18EPA 2471187
NCUC36BT4+TDR+ furnace: NF96U045V3BAHRI reference: 21240388319.508.50181002.10EPA 2471195
NCHC36CT4+TDR+ furnace: NF97U090M3CAHRI reference: 21240385519.508.50180002.02EPA 2471203
NCHC42CT4+TDR+ furnace: NF97X080V5CAHRI reference: 21240387119.508.70183002.16EPA 2471223
NCHC30BT4+TDR+ furnace: NF96U070V3BAHRI reference: 21240384619.508.50186002.10EPA 2471229
NCUC30BT4+TDR+ furnace: NF96U070V3BAHRI reference: 21240387619.508.50180002.12EPA 2471235
NCHC30BT4+TDR+ furnace: NF97U070M3BAHRI reference: 21240384719.508.50186002.10EPA 2471293

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.