NS22H36MA4-**A
NS22H SERIES
73 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for NS22H36MA4-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 73 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 17.5–20.5 | 73 / 73 |
| EER2 · BTU/Wh | 11.7–12 | 73 / 73 |
| HSPF2 · BTU/Wh | 8.5–9 | 73 / 73 |
| Cooling capacity · BTU/h | 34,000–36,000 | 73 / 73 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 32,800–35,000 | 73 / 73 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 21,800–23,000 | 73 / 73 |
| Heating capacity at 5°F / −15°C · BTU/h | 17,800–18,600 | 73 / 73 |
| COP at 5°F / −15°C | 2.02–2.3 | 73 / 73 |
| Equipment / loop type | HP - Split System | 73 / 73 |
| Refrigerant / source-reported GWP | R-410A (GWP:2088) | 73 / 73 |
| Compressor staging | Continuously variable | 73 / 73 |
| Connected capability | No | 73 / 73 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
NCUC48CT4+TDR+ furnace: NF96U110V5CAHRI reference: 212403899 | 20.50 | 8.80 | 18200 | 2.24 | EPA 2471377 → |
NCUC48CT4+TDR+ furnace: NF97U090M4CAHRI reference: 212403901 | 20.50 | 8.80 | 18400 | 2.22 | EPA 2471633 → |
NCUU48CP4+TDR+TXV+ furnace: NF97U110M5CAHRI reference: 212403937 | 20.50 | 8.80 | 18100 | 2.24 | EPA 2472024 → |
NCUU48CP4+TDR+TXV+ furnace: NF97U090M4CAHRI reference: 212403935 | 20.50 | 8.80 | 18400 | 2.22 | EPA 2472155 → |
NCUC48CT4+TDR+ furnace: NF97U110M5CAHRI reference: 212403903 | 20.50 | 8.80 | 18100 | 2.24 | EPA 2472509 → |
NCUU48CP4+TDR+TXV+ furnace: NF96U110V5CAHRI reference: 212403933 | 20.50 | 8.80 | 18200 | 2.24 | EPA 2472557 → |
NCUC36BT4+TDR+ furnace: NF97U070M3BAHRI reference: 212403885 | 20.00 | 8.50 | 18000 | 2.12 | EPA 2471205 → |
NCHC36CT4+TDR+ furnace: NF97U110M5CAHRI reference: 212403858 | 20.00 | 8.50 | 17900 | 2.04 | EPA 2471291 → |
NAM42V2TA4AHRI reference: 212403841 | 20.00 | 9.00 | 18300 | 2.30 | EPA 2471363 → |
NCUC48CT4+TDR+ furnace: NF97X080V4CAHRI reference: 212403904 | 20.00 | 8.80 | 18300 | 2.22 | EPA 2471365 → |
NCUC48CT4+TDR+ furnace: NF96U090V5CAHRI reference: 212403898 | 20.00 | 8.80 | 18200 | 2.22 | EPA 2471376 → |
NCUU48CP4+TDR+TXV+ furnace: NF97X080V4CAHRI reference: 212403938 | 20.00 | 8.80 | 18300 | 2.22 | EPA 2471618 → |
NAM36V2TA4AHRI reference: 212403838 | 20.00 | 9.00 | 18200 | 2.26 | EPA 2471700 → |
NCHC36CT4+TDR+ furnace: NF97X080V5CAHRI reference: 212403860 | 20.00 | 8.50 | 18300 | 2.04 | EPA 2471721 → |
NCUU48CP4+TDR+TXV+ furnace: NF97X080V5CAHRI reference: 212403939 | 20.00 | 8.80 | 18400 | 2.22 | EPA 2471801 → |
NCUC36BT4+TDR+ furnace: NF96U070V3BAHRI reference: 212403884 | 20.00 | 8.50 | 18000 | 2.12 | EPA 2471816 → |
NCUC48CT4+TDR+ furnace: NF96U090V3CAHRI reference: 212403897 | 20.00 | 8.80 | 18300 | 2.22 | EPA 2471851 → |
NCUU48CP4+TDR+TXV+ furnace: NF97U090M3CAHRI reference: 212403934 | 20.00 | 8.80 | 18300 | 2.22 | EPA 2472020 → |
NCUU36BP4+TDR+TXV+ furnace: NF97X060V3BAHRI reference: 212403921 | 20.00 | 8.50 | 18000 | 2.12 | EPA 2472033 → |
NCUU36BP4+TDR+TXV+ furnace: NF96U070V3BAHRI reference: 212403918 | 20.00 | 8.50 | 18000 | 2.12 | EPA 2472036 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →