GE / AIR-SOURCE HEAT PUMP

NS22H36MA4-**A

NS22H SERIES

73 published source records · source checked Sep 21, 2026

SEER2 range17.5–20.5BTU/Wh
HSPF2 range8.5–9BTU/Wh
Cooling capacity34,000–36,000BTU/h

Each efficiency range summarizes published EPA records for NS22H36MA4-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 73 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh17.5–20.573 / 73
EER2 · BTU/Wh11.7–1273 / 73
HSPF2 · BTU/Wh8.5–973 / 73
Cooling capacity · BTU/h34,000–36,00073 / 73
Heating capacity at 47°F / 8.3°C · BTU/h32,800–35,00073 / 73
Heating capacity at 17°F / −8.3°C · BTU/h21,800–23,00073 / 73
Heating capacity at 5°F / −15°C · BTU/h17,800–18,60073 / 73
COP at 5°F / −15°C2.02–2.373 / 73
Equipment / loop typeHP - Split System73 / 73
Refrigerant / source-reported GWPR-410A (GWP:2088)73 / 73
Compressor stagingContinuously variable73 / 73
Connected capabilityNo73 / 73

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
NCUC48CT4+TDR+ furnace: NF96U110V5CAHRI reference: 21240389920.508.80182002.24EPA 2471377
NCUC48CT4+TDR+ furnace: NF97U090M4CAHRI reference: 21240390120.508.80184002.22EPA 2471633
NCUU48CP4+TDR+TXV+ furnace: NF97U110M5CAHRI reference: 21240393720.508.80181002.24EPA 2472024
NCUU48CP4+TDR+TXV+ furnace: NF97U090M4CAHRI reference: 21240393520.508.80184002.22EPA 2472155
NCUC48CT4+TDR+ furnace: NF97U110M5CAHRI reference: 21240390320.508.80181002.24EPA 2472509
NCUU48CP4+TDR+TXV+ furnace: NF96U110V5CAHRI reference: 21240393320.508.80182002.24EPA 2472557
NCUC36BT4+TDR+ furnace: NF97U070M3BAHRI reference: 21240388520.008.50180002.12EPA 2471205
NCHC36CT4+TDR+ furnace: NF97U110M5CAHRI reference: 21240385820.008.50179002.04EPA 2471291
NAM42V2TA4AHRI reference: 21240384120.009.00183002.30EPA 2471363
NCUC48CT4+TDR+ furnace: NF97X080V4CAHRI reference: 21240390420.008.80183002.22EPA 2471365
NCUC48CT4+TDR+ furnace: NF96U090V5CAHRI reference: 21240389820.008.80182002.22EPA 2471376
NCUU48CP4+TDR+TXV+ furnace: NF97X080V4CAHRI reference: 21240393820.008.80183002.22EPA 2471618
NAM36V2TA4AHRI reference: 21240383820.009.00182002.26EPA 2471700
NCHC36CT4+TDR+ furnace: NF97X080V5CAHRI reference: 21240386020.008.50183002.04EPA 2471721
NCUU48CP4+TDR+TXV+ furnace: NF97X080V5CAHRI reference: 21240393920.008.80184002.22EPA 2471801
NCUC36BT4+TDR+ furnace: NF96U070V3BAHRI reference: 21240388420.008.50180002.12EPA 2471816
NCUC48CT4+TDR+ furnace: NF96U090V3CAHRI reference: 21240389720.008.80183002.22EPA 2471851
NCUU48CP4+TDR+TXV+ furnace: NF97U090M3CAHRI reference: 21240393420.008.80183002.22EPA 2472020
NCUU36BP4+TDR+TXV+ furnace: NF97X060V3BAHRI reference: 21240392120.008.50180002.12EPA 2472033
NCUU36BP4+TDR+TXV+ furnace: NF96U070V3BAHRI reference: 21240391820.008.50180002.12EPA 2472036