GE / AIR-SOURCE HEAT PUMP

NS19H60MA5-**A

NS19H SERIES · NS19H Series · source records, page 3

66 published source records · source checked Sep 21, 2026

SEER2 range16.5–18.5BTU/Wh
HSPF2 range7.8–9BTU/Wh
Cooling capacity46,000–48,000BTU/h

Each efficiency range summarizes published EPA records for NS19H60MA5-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 66 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh16.5–18.566 / 66
EER2 · BTU/Wh11–11.766 / 66
HSPF2 · BTU/Wh7.8–966 / 66
Cooling capacity · BTU/h46,000–48,00066 / 66
Heating capacity at 47°F / 8.3°C · BTU/h45,000–50,50066 / 66
Heating capacity at 17°F / −8.3°C · BTU/h27,600–33,20066 / 66
Heating capacity at 5°F / −15°C · BTU/h21,800–32,60066 / 66
COP at 5°F / −15°C1.8–2.2666 / 66
Equipment / loop typeHP - Split System66 / 66
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)66 / 66
Compressor stagingContinuously variable66 / 66
Connected capabilityNo66 / 66

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
NCHC51CT5*-**+TDR+ furnace: NF97U090V5C*AHRI reference: 21773333917.508.00292001.90EPA 4513060
NCUC50CT5*-**+TDR+ furnace: NF80U110T5C*AHRI reference: 21773303617.508.20234001.88EPA 4513064
NCDC60DT5*-**+TDR+ furnace: NF97D110T5C*AHRI reference: 21815979917.508.50298001.92EPA 4573272
NCHC51CT5*-**+TDR+ furnace: NF80U110T5C*AHRI reference: 21773313417.008.20286001.92EPA 4512885
NCHC51CT5*-**+TDR+ furnace: NF80U090S5C*AHRI reference: 21773313517.008.20286001.90EPA 4512886
NCHC51CT5*-**+TDR+ furnace: NF96U090S4C*AHRI reference: 21773313817.008.20288001.90EPA 4512889
NCHC51CT5*-**+TDR+ furnace: NF80X100V5C*AHRI reference: 21773314117.008.20290001.92EPA 4512892
NCHC51CT5*-**+TDR+ furnace: NF98U090M4C*AHRI reference: 21773314317.008.20290001.90EPA 4512893
NCHC51CT5*-**+TDR+ furnace: NF98U090M5C*AHRI reference: 21773314417.008.20290001.90EPA 4512894
NCHC51CT5*-**+TDR+ furnace: NF98U110M5C*AHRI reference: 21773314517.008.20290001.92EPA 4512895
NCDC60CT5*-**+TDR+ furnace: NF96D090S4C*AHRI reference: 21773314717.008.00290001.94EPA 4512897
NCUC50CT5*-**+TDR+ furnace: NF95X100S5C*AHRI reference: 21773303517.008.10238001.82EPA 4512974
NCUC50CT5*-**+TDR+ furnace: NF80U090S5C*AHRI reference: 21773303717.008.20232001.88EPA 4512975
NCUC50CT5*-**+TDR+ furnace: NF96U110S5C*AHRI reference: 21773304117.008.20234001.86EPA 4512978
NCU[C,U]48CT5*-**+TDR+ furnace: NF80U110T5C*AHRI reference: 21773305417.007.80218001.84EPA 4512986
NCU[C,U]48CT5*-**+TDR+ furnace: NF80U090S5C*AHRI reference: 21773305517.007.80220001.82EPA 4512987
NCU[C,U]48CT5*-**+TDR+ furnace: NF96U110S5C*AHRI reference: 21773305917.007.80220001.82EPA 4512990
NCU[C,U]48CT5*-**+TDR+ furnace: NF95X080S4C*AHRI reference: 21773305317.007.80220001.80EPA 4513067
NCHC51CT5*-**+TDR+ furnace: NF97U110T5C*AHRI reference: 21815980217.008.20290001.90EPA 4573269
NCUC50CT5*-**+TDR+ furnace: NF97U110T5C*AHRI reference: 21815980117.008.20234001.86EPA 4573270

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →