GE / AIR-SOURCE HEAT PUMP

NS19H60MA5-**A

NS19H SERIES · NS19H Series · source records, page 2

66 published source records · source checked Sep 21, 2026

SEER2 range16.5–18.5BTU/Wh
HSPF2 range7.8–9BTU/Wh
Cooling capacity46,000–48,000BTU/h

Each efficiency range summarizes published EPA records for NS19H60MA5-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 66 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh16.5–18.566 / 66
EER2 · BTU/Wh11–11.766 / 66
HSPF2 · BTU/Wh7.8–966 / 66
Cooling capacity · BTU/h46,000–48,00066 / 66
Heating capacity at 47°F / 8.3°C · BTU/h45,000–50,50066 / 66
Heating capacity at 17°F / −8.3°C · BTU/h27,600–33,20066 / 66
Heating capacity at 5°F / −15°C · BTU/h21,800–32,60066 / 66
COP at 5°F / −15°C1.8–2.2666 / 66
Equipment / loop typeHP - Split System66 / 66
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)66 / 66
Compressor stagingContinuously variable66 / 66
Connected capabilityNo66 / 66

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
NCUC50CT5*-**+TDR+ furnace: NF80U110V5C*AHRI reference: 21773332318.008.00236001.86EPA 4513054
NCUC50CT5*-**+TDR+ furnace: NF97U090V3C*AHRI reference: 21773332418.007.80232001.86EPA 4513055
NCHC42BT5*-**+TDR+ furnace: NF80U090V4B*AHRI reference: 21773333418.007.80266001.84EPA 4513058
NCUC50CT5*-**+TDR+ furnace: NF80L110S5C*AHRI reference: 21773303918.008.20236001.88EPA 4513065
NCU[C,U]48CT5*-**+TDR+ furnace: NF80U110S5C*AHRI reference: 21773305618.007.80222001.82EPA 4513068
NCUC50CT5*-**+TDR+ furnace: NF97U090V5C*AHRI reference: 21773332518.007.80238001.86EPA 4513075
NCU[C,U]48CT5*-**+TDR+ furnace: NF97U090T4C*AHRI reference: 21815980018.007.80220001.82EPA 4573271
NCHC51CT5*-**+TDR+ furnace: NF80U110S5C*AHRI reference: 21773313617.508.20290001.90EPA 4512887
NCHC51CT5*-**+TDR+ furnace: NF80L110S5C*AHRI reference: 21773313717.508.20290001.90EPA 4512888
NCHC51CT5*-**+TDR+ furnace: NF97U110V5C*AHRI reference: 21773314017.508.10290001.92EPA 4512891
NCUC50CT5*-**+TDR+ furnace: NF80X100S5C*AHRI reference: 21773303417.508.20238001.84EPA 4512973
NCUC50CT5*-**+TDR+ furnace: NF97U110V5C*AHRI reference: 21773304217.508.00236001.88EPA 4512979
NCU[C,U]48CT5*-**+TDR+ furnace: NF80X100S5C*AHRI reference: 21773305217.507.80224001.80EPA 4512985
NCHC48CT5*-**+TDR+ furnace: NF80U090S5C*AHRI reference: 21773307017.507.80238001.80EPA 4512991
NCHC48CT5*-**+TDR+ furnace: NF80U110S5C*AHRI reference: 21773307117.507.80236001.80EPA 4512992
NCHC48CT5*-**+TDR+ furnace: NF80L110S5C*AHRI reference: 21773307217.507.80236001.80EPA 4512993
NCHC51CT5*-**+TDRAHRI reference: 21773328117.508.10290001.90EPA 4513039
NCDC48CT5*-**+TDR+ furnace: NF97D090V5C*AHRI reference: 21773333017.508.10248001.88EPA 4513056
NCDC48CT5*-**+TDR+ furnace: NF97D110V5C*AHRI reference: 21773333117.508.10248001.88EPA 4513057
NCHC51CT5*-**+TDR+ furnace: NF80U110V5C*AHRI reference: 21773333817.508.10290001.90EPA 4513059