GE / AIR-SOURCE HEAT PUMP

NS17H36SA4-**A

NS17 Series · NS17H · NS17H SERIES · NS17H Series · source records, page 15

324 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.8BTU/Wh
HSPF2 range7.8–8.7BTU/Wh
Cooling capacity35,200–36,000BTU/h

Each efficiency range summarizes published EPA records for NS17H36SA4-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 324 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.8324 / 324
EER2 · BTU/Wh12.2–14324 / 324
HSPF2 · BTU/Wh7.8–8.7324 / 324
Cooling capacity · BTU/h35,200–36,000324 / 324
Heating capacity at 47°F / 8.3°C · BTU/h32,400–36,000324 / 324
Heating capacity at 17°F / −8.3°C · BTU/h21,400–24,000324 / 324
Heating capacity at 5°F / −15°C · BTU/h16,800–19,300324 / 324
COP at 5°F / −15°C2.08–2.34324 / 324
Equipment / loop typeHP - Split System324 / 324
Refrigerant / source-reported GWPR-410A (GWP:2088)324 / 324
Compressor stagingSingle stage324 / 324
Connected capabilityNo324 / 324

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
NCDC36BT5D-**+TDR+ furnace: NF80D090T4B*AHRI reference: 21749092815.608.00187002.12EPA 4432023 →
NAM42P1TA5D-**AHRI reference: 21749091615.608.10176002.16EPA 4432955 →
NCHC48BT5D-**+TDR+ furnace: NF95X040S3B*AHRI reference: 21749122415.607.80175002.20EPA 4433029 →
NCHC42BT5D-**+TDR+ furnace: NF96U070V3B*AHRI reference: 21749131315.608.10189002.26EPA 4433079 →
NCHC48BT5D-**+TDR+ furnace: NF96U070V3B*AHRI reference: 21749131415.608.00178002.20EPA 4433080 →
NCDC48CT5D-**+TDR+ furnace: NF97D110M5C*AHRI reference: 21749136515.608.60190002.26EPA 4433114 →
NCHC48BT5D-**+TDR+ furnace: NF97U070M3B*AHRI reference: 21749139215.608.00178002.20EPA 4433130 →
NCHC42BT5D-**+TDR+ furnace: NF97U070V3B*AHRI reference: 21749140415.608.10189002.26EPA 4433141 →
NCHC48BT5D-**+TDR+ furnace: NF97U070V3B*AHRI reference: 21749140515.608.00178002.20EPA 4433142 →
NCHC42BT5D-**+TDR+ furnace: NF97X040V3B*AHRI reference: 21749145815.608.10188002.24EPA 4433147 →
NCHC48BT5D-**+TDR+ furnace: NF97X040V3B*AHRI reference: 21749145915.608.00178002.20EPA 4433148 →
NCHC48BT5D-**+TDR+ furnace: NF96U070S3B*AHRI reference: 21749130115.607.80174002.18EPA 4433223 →
NCHC42BT5D-**+TDR+ furnace: NF97U070M3B*AHRI reference: 21749139115.608.10189002.26EPA 4433270 →
NCHC48BT5D-**+TDR+ furnace: NF97X060V3B*AHRI reference: 21749147215.608.00178002.20EPA 4433271 →
NCHC42BT5D-**+TDR+ furnace: NF97X060V3B*AHRI reference: 21749147115.608.10189002.24EPA 4433346 →
NAM36E1TA5D-**AHRI reference: 21749091315.507.80171002.16EPA 4432953 →
NCDC3036CT4+TDR+ furnace: NF97D090M4C-*AHRI reference: 21335583715.408.00189002.12EPA 2841272 →
NCDC3036CT4+TDR+ furnace: NF97D110M5C-*AHRI reference: 21335583815.408.00189002.08EPA 2841273 →
NCHC42BT4+TDR+ furnace: NF97U045V3BAHRI reference: 21528340115.408.10188002.22EPA 3619278 →
NCHC42BT5D-**+TDR+ furnace: NF97U045V3BAHRI reference: 21528340515.408.10188002.22EPA 3619280 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →