GE / AIR-SOURCE HEAT PUMP

NS17H36SA4-**A

NS17 Series · NS17H · NS17H SERIES · NS17H Series · source records, page 14

324 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.8BTU/Wh
HSPF2 range7.8–8.7BTU/Wh
Cooling capacity35,200–36,000BTU/h

Each efficiency range summarizes published EPA records for NS17H36SA4-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 324 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.8324 / 324
EER2 · BTU/Wh12.2–14324 / 324
HSPF2 · BTU/Wh7.8–8.7324 / 324
Cooling capacity · BTU/h35,200–36,000324 / 324
Heating capacity at 47°F / 8.3°C · BTU/h32,400–36,000324 / 324
Heating capacity at 17°F / −8.3°C · BTU/h21,400–24,000324 / 324
Heating capacity at 5°F / −15°C · BTU/h16,800–19,300324 / 324
COP at 5°F / −15°C2.08–2.34324 / 324
Equipment / loop typeHP - Split System324 / 324
Refrigerant / source-reported GWPR-410A (GWP:2088)324 / 324
Compressor stagingSingle stage324 / 324
Connected capabilityNo324 / 324

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
NCUC50CT5D-**+TDR+ furnace: NF80X100S5C*AHRI reference: 21749120015.807.80176002.12EPA 4433263
NCUC36BT5D-**+TDR+ furnace: NF97X060V3B*AHRI reference: 21749147315.807.80174002.12EPA 4433272
NCUC36BT5D-**+TDR+ furnace: NF95X040S3B*AHRI reference: 21749122515.807.80170002.12EPA 4433298
NCUC50CT5D-**+TDR+ furnace: NF97U090V5C*AHRI reference: 21749143615.807.80176002.12EPA 4433321
NCUC50CT5D-**+TDR+ furnace: NF97U090M5C*AHRI reference: 21749142515.807.80176002.12EPA 4433326
NCUC50CT5D-**+TDR+ furnace: NF97X080V5C*AHRI reference: 21749148515.807.80174002.10EPA 4433352
NCDC48CT5D-**+TDR+ furnace: NF96D110V5C*AHRI reference: 21749126615.808.60190002.26EPA 4433356
NAM42P1TA4AHRI reference: 21164162215.608.10176002.16EPA 2454676
NCHC48BT4+TDR+ furnace: NF97U070M3B-*AHRI reference: 21026238615.608.00178002.20EPA 2461347
NCHC48BT4+TDR+ furnace: NF97X060V3B-*AHRI reference: 21026238515.608.00178002.20EPA 2461358
NCHC48BT4+TDR+ furnace: NF97X040V3B-*AHRI reference: 21026238415.608.00178002.20EPA 2461362
NCHC48BT4+TDR+ furnace: NF95X040S3B-*AHRI reference: 21026237415.607.80175002.20EPA 2461555
NCHC48BT4+TDR+ furnace: NF96U070S3B-*AHRI reference: 21026238115.607.80174002.18EPA 2462055
NCDC48CT4+TDR+ furnace: NF97D110M5C-*AHRI reference: 21335584415.608.60190002.26EPA 2841285
NCDC3036BT4+TDR+ furnace: NF80D090T4B-*AHRI reference: 21335583015.608.00187002.12EPA 2841307
NCHC42BT4+TDR+ furnace: NF97U070V3BAHRI reference: 21528340315.608.10189002.26EPA 3619279
NCHC42BT5D-**+TDR+ furnace: NF97U070V3BAHRI reference: 21528340715.608.10189002.26EPA 3619281
NCHC48BT4+TDR+ furnace: NF97U070V3BAHRI reference: 21528342415.608.00178002.20EPA 3619429
NCHC48BT5D-**+TDR+ furnace: NF97U070V3BAHRI reference: 21528342815.608.00178002.20EPA 3619431
NCHC48BT4+TDR+ furnace: NF98U070M3BAHRI reference: 21543820115.608.00178002.20EPA 3627532