GE / AIR-SOURCE HEAT PUMP

NS17H30SA4-**A

NS17 Series · NS17H · NS17H SERIES · NS17H Series · source records, page 9

254 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.2BTU/Wh
HSPF2 range7.8–8.6BTU/Wh
Cooling capacity28,200–30,000BTU/h

Each efficiency range summarizes published EPA records for NS17H30SA4-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 254 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.2254 / 254
EER2 · BTU/Wh12.2–13.5254 / 254
HSPF2 · BTU/Wh7.8–8.6254 / 254
Cooling capacity · BTU/h28,200–30,000254 / 254
Heating capacity at 47°F / 8.3°C · BTU/h26,600–30,000254 / 254
Heating capacity at 17°F / −8.3°C · BTU/h17,400–19,600254 / 254
Heating capacity at 5°F / −15°C · BTU/h13,200–15,400254 / 254
COP at 5°F / −15°C1.96–2.38254 / 254
Equipment / loop typeHP - Split System254 / 254
Refrigerant / source-reported GWPR-410A (GWP:2088)254 / 254
Compressor stagingSingle stage254 / 254
Connected capabilityNo254 / 254

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
NCDC42BT4+TDR+ furnace: NF97D070M3B-*AHRI reference: 21335582915.608.60154002.32EPA 2841306
NCUC36BT5D-**+TDR+ furnace: NF97U045V3BAHRI reference: 21528336615.608.10145002.26EPA 3619333
NCUU30BP4+TDR+TXV+ furnace: NF97U070V3BAHRI reference: 21528337315.608.00145002.18EPA 3619336
NCUU36BP4+TDR+TXV+ furnace: NF97U045V3BAHRI reference: 21528337515.608.10145002.26EPA 3619337
NCHC36CT5D-**+TDR+ furnace: NF97U090V3CAHRI reference: 21528334715.608.30147002.22EPA 3619407
NCUC30BT4+TDR+ furnace: NF97U070V3BAHRI reference: 21528335615.608.00145002.18EPA 3619410
NCUC30BT5D-**+TDR+ furnace: NF97U070V3BAHRI reference: 21528336015.608.00145002.18EPA 3619412
NCUC36BT4+TDR+ furnace: NF97U045V3BAHRI reference: 21528336215.608.10145002.26EPA 3619413
NCHC30BT4+TDR+ furnace: NF97U045V3BAHRI reference: 21528333315.607.80137002.06EPA 3619419
NCHC30BT5D-**+TDR+ furnace: NF97U045V3BAHRI reference: 21528333715.607.80137002.06EPA 3619421
NCHC36CT4+TDR+ furnace: NF97U090V3CAHRI reference: 21528334115.608.30147002.22EPA 3619423
NCUU30BP4+TDR+TXV+ furnace: NF98U070M3BAHRI reference: 21543819415.608.00145002.18EPA 3627530
NCHC36CT4+TDR+ furnace: NF98U090M3CAHRI reference: 21543818915.608.30147002.22EPA 3627544
NCHC36CT4+TDR+ furnace: NF98U090M4CAHRI reference: 21543819015.608.30144002.22EPA 3627545
NCUC30BT4+TDR+ furnace: NF98U070M3BAHRI reference: 21543819215.608.00145002.18EPA 3627547
NCHC36CT5D-**+TDR+ furnace: NF80L110S5C*AHRI reference: 21749098015.608.30146002.22EPA 4431974
NCHC36CT5D-**+TDR+ furnace: NF80U110S5C*AHRI reference: 21749110715.608.30146002.22EPA 4431981
NCHC36CT5D-**+TDR+ furnace: NF96U110S5C*AHRI reference: 21749133715.608.50148002.26EPA 4431995
NCDC42BT5D-**+TDR+ furnace: NF97D070M3B*AHRI reference: 21749135615.608.60154002.32EPA 4431999
NCUC30AT5D-**+TDR+ furnace: NF80U070T3A*AHRI reference: 21749104115.608.00144002.20EPA 4432003

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →