GE / AIR-SOURCE HEAT PUMP

NS17H30SA4-**A

NS17 Series · NS17H · NS17H SERIES · NS17H Series · source records, page 8

254 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.2BTU/Wh
HSPF2 range7.8–8.6BTU/Wh
Cooling capacity28,200–30,000BTU/h

Each efficiency range summarizes published EPA records for NS17H30SA4-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 254 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.2254 / 254
EER2 · BTU/Wh12.2–13.5254 / 254
HSPF2 · BTU/Wh7.8–8.6254 / 254
Cooling capacity · BTU/h28,200–30,000254 / 254
Heating capacity at 47°F / 8.3°C · BTU/h26,600–30,000254 / 254
Heating capacity at 17°F / −8.3°C · BTU/h17,400–19,600254 / 254
Heating capacity at 5°F / −15°C · BTU/h13,200–15,400254 / 254
COP at 5°F / −15°C1.96–2.38254 / 254
Equipment / loop typeHP - Split System254 / 254
Refrigerant / source-reported GWPR-410A (GWP:2088)254 / 254
Compressor stagingSingle stage254 / 254
Connected capabilityNo254 / 254

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
NCUC30BT4+TDR+ furnace: NF97X040V3B-*AHRI reference: 21026232315.608.00145002.20EPA 2460008
NCHC30AT4+TDR+ furnace: NF80U070V3A-*AHRI reference: 21026228215.607.80139001.98EPA 2460017
NCHC36CT4+TDR+ furnace: NF97U090M3C-*AHRI reference: 21026229815.608.30147002.22EPA 2460269
NCUU36BP4+TDR+TXV+ furnace: NF96U045S3B-*AHRI reference: 21026226715.608.10146002.26EPA 2460281
NCUC30AT4+TDR+ furnace: NF80U070T3A-*AHRI reference: 21026230515.608.00144002.20EPA 2460304
NCUU36BP4+TDR+TXV+ furnace: NF96U070S3B-*AHRI reference: 21026226815.608.10143002.26EPA 2460791
NCUU30BP4+TDR+TXV+ furnace: NF95X060S3B-*AHRI reference: 21026223815.608.00143002.20EPA 2461549
NCUU36BP4+TDR+TXV+ furnace: NF95X040S3B-*AHRI reference: 21026226115.608.00146002.26EPA 2461552
NCUU30BP4+TDR+TXV+ furnace: NF80U090V4B-*AHRI reference: 21026224715.608.10145002.18EPA 2461560
NCUC36BT4+TDR+ furnace: NF96U045S3B-*AHRI reference: 21026234315.608.10146002.26EPA 2461562
NCHC36CT4+TDR+ furnace: NF97U090M4C-*AHRI reference: 21026229915.608.30144002.22EPA 2461748
NCUC30AT4+TDR+ furnace: NF80X040S3A-*AHRI reference: 21026230215.607.80142002.20EPA 2461754
NCUC30AT4+TDR+ furnace: NF80U070V3A-*AHRI reference: 21026231015.608.00145002.20EPA 2461771
NCUU30AP4+TDR+TXV+ furnace: NF80X040S3A-*AHRI reference: 21026222715.607.80142002.20EPA 2461772
NCUU30AP4+TDR+TXV+ furnace: NF80X060S3A-*AHRI reference: 21026222815.607.80142002.20EPA 2461773
NCUU30AP4+TDR+TXV+ furnace: NF80U070V3A-*AHRI reference: 21026223515.608.00145002.20EPA 2461775
NCUC30AT4+TDR+ furnace: NF80X060S3A-*AHRI reference: 21026230315.607.80142002.20EPA 2461778
NCHC36CT4+TDR+ furnace: NF96U110S5C-*AHRI reference: 21026229315.608.50148002.26EPA 2461794
NCUU36BP4+TDR+TXV+ furnace: NF80X080S4B-*AHRI reference: 21026226015.608.10146002.24EPA 2462310
NCDC42BT4+TDR+ furnace: NF96D070S4B-*AHRI reference: 21335582815.608.60153002.32EPA 2841305

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →