GE / AIR-SOURCE HEAT PUMP

NS17H30SA4-**A

NS17 Series · NS17H · NS17H SERIES · NS17H Series · source records, page 2

254 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.2BTU/Wh
HSPF2 range7.8–8.6BTU/Wh
Cooling capacity28,200–30,000BTU/h

Each efficiency range summarizes published EPA records for NS17H30SA4-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 254 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.2254 / 254
EER2 · BTU/Wh12.2–13.5254 / 254
HSPF2 · BTU/Wh7.8–8.6254 / 254
Cooling capacity · BTU/h28,200–30,000254 / 254
Heating capacity at 47°F / 8.3°C · BTU/h26,600–30,000254 / 254
Heating capacity at 17°F / −8.3°C · BTU/h17,400–19,600254 / 254
Heating capacity at 5°F / −15°C · BTU/h13,200–15,400254 / 254
COP at 5°F / −15°C1.96–2.38254 / 254
Equipment / loop typeHP - Split System254 / 254
Refrigerant / source-reported GWPR-410A (GWP:2088)254 / 254
Compressor stagingSingle stage254 / 254
Connected capabilityNo254 / 254

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
NCHC30BT5D-**+TDR+ furnace: NF80U070S3B*AHRI reference: 21749102716.207.80134002.12EPA 4433242 →
NCUU30AP4+TDR+TXV+ furnace: NF80X060V3A-*AHRI reference: 21026223416.008.10143002.24EPA 2454984 →
NCUC36AT4+TDR+ furnace: NF80U070T3A-*AHRI reference: 21026232916.008.10143002.26EPA 2455004 →
NCUC30AT4+TDR+ furnace: NF80X060V3A-*AHRI reference: 21026230916.008.10143002.24EPA 2455055 →
NCUC36AT4+TDR+ furnace: NF80U070S3A-*AHRI reference: 21026233116.008.10144002.28EPA 2455060 →
NCUU36AP4+TDR+TXV+ furnace: NF80U045S3A-*AHRI reference: 21026225516.008.10144002.28EPA 2455140 →
NCUU36BP4+TDR+TXV+ furnace: NF97X040V3B-*AHRI reference: 21026227116.008.10144002.28EPA 2455162 →
NCUU36AP4+TDR+TXV+ furnace: NF80U045T3A-*AHRI reference: 21026225316.008.10143002.28EPA 2455225 →
NCUU30BP4+TDR+TXV+ furnace: NF80U090T4B-*AHRI reference: 21026223916.008.00142002.22EPA 2455257 →
NCUC36BT4+TDR+ furnace: NF80U070S3B-*AHRI reference: 21026234116.008.10143002.26EPA 2457558 →
NCUC36AT4+TDR+ furnace: NF80U045S3A-*AHRI reference: 21026233016.008.10144002.28EPA 2457563 →
NCUU36BP4+TDR+TXV+ furnace: NF97U070M3B-*AHRI reference: 21026227316.008.10145002.28EPA 2457567 →
NAM30V2TA4AHRI reference: 21067785716.008.50150002.38EPA 2457995 →
NCUU36BP4+TDR+TXV+ furnace: NF80U090V4B-*AHRI reference: 21026227016.008.10144002.28EPA 2459766 →
NCUC36BT4+TDR+ furnace: NF97X040V3B-*AHRI reference: 21026234716.008.10144002.28EPA 2459817 →
NCUC36BT4+TDR+ furnace: NF97U070M3B-*AHRI reference: 21026234916.008.10145002.28EPA 2459829 →
NCUU36AP4+TDR+TXV+ furnace: NF80L070S3A-*AHRI reference: 21026225716.008.10144002.28EPA 2459832 →
NCUC30BT4+TDR+ furnace: NF80U090S4B-*AHRI reference: 21026231816.008.00142002.22EPA 2460044 →
NCUU36BP4+TDR+TXV+ furnace: NF80U070S3B-*AHRI reference: 21026226516.008.10143002.26EPA 2460271 →
NCUC30BT4+TDR+ furnace: NF80U090T4B-*AHRI reference: 21026231416.008.00142002.22EPA 2460306 →