GE / AIR-SOURCE HEAT PUMP

NS17H30SA4-**A

NS17 Series · NS17H · NS17H SERIES · NS17H Series

254 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.2BTU/Wh
HSPF2 range7.8–8.6BTU/Wh
Cooling capacity28,200–30,000BTU/h

Each efficiency range summarizes published EPA records for NS17H30SA4-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 254 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.2254 / 254
EER2 · BTU/Wh12.2–13.5254 / 254
HSPF2 · BTU/Wh7.8–8.6254 / 254
Cooling capacity · BTU/h28,200–30,000254 / 254
Heating capacity at 47°F / 8.3°C · BTU/h26,600–30,000254 / 254
Heating capacity at 17°F / −8.3°C · BTU/h17,400–19,600254 / 254
Heating capacity at 5°F / −15°C · BTU/h13,200–15,400254 / 254
COP at 5°F / −15°C1.96–2.38254 / 254
Equipment / loop typeHP - Split System254 / 254
Refrigerant / source-reported GWPR-410A (GWP:2088)254 / 254
Compressor stagingSingle stage254 / 254
Connected capabilityNo254 / 254

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
NCUC36BT4+TDR+ furnace: NF80X080V4B-*AHRI reference: 21026234516.208.10145002.30EPA 2455035
NCUC36BT4+TDR+ furnace: NF80U090S4B-*AHRI reference: 21026234216.208.10141002.26EPA 2455042
NCUU36AP4+TDR+TXV+ furnace: NF80X060V3A-*AHRI reference: 21026225816.208.10145002.30EPA 2455069
NCUC36BT4+TDR+ furnace: NF80U090T4B-*AHRI reference: 21026233816.208.10141002.28EPA 2455258
NCUU36BP4+TDR+TXV+ furnace: NF80U090S4B-*AHRI reference: 21026226616.208.10141002.26EPA 2455363
NCUU36BP4+TDR+TXV+ furnace: NF80U090T4B-*AHRI reference: 21026226316.208.10141002.28EPA 2460012
NCUC36AT4+TDR+ furnace: NF80X060V3A-*AHRI reference: 21026233316.208.10145002.30EPA 2460036
NCUU36BP4+TDR+TXV+ furnace: NF80X080V4B-*AHRI reference: 21026226916.208.10145002.30EPA 2460789
NCDC42BT4+TDR+ furnace: NF80D090S4B-*AHRI reference: 21335582616.208.60148002.34EPA 2841315
NCHC30BT5D-**+TDR+ furnace: NF80U090T4B*AHRI reference: 21749108716.207.80134002.12EPA 4431939
NCDC42BT5D-**+TDR+ furnace: NF80D090S4B*AHRI reference: 21749092416.208.60148002.34EPA 4432019
NCHC30BT5D-**+TDR+ furnace: NF80L070S3B*AHRI reference: 21749095916.207.80134002.12EPA 4432951
NCUC36BT5D-**+TDR+ furnace: NF80U090T4B*AHRI reference: 21749108916.208.10141002.28EPA 4432969
NCUC36AT5D-**+TDR+ furnace: NF80X060V3A*AHRI reference: 21749117016.208.10145002.30EPA 4433015
NCHC30BT5D-**+TDR+ furnace: NF80U090S4B*AHRI reference: 21749106016.207.80134002.10EPA 4433198
NCUC36BT5D-**+TDR+ furnace: NF80U090S4B*AHRI reference: 21749106216.208.10141002.26EPA 4433200
NCHC30BT5D-**+TDR+ furnace: NF80X080V4B*AHRI reference: 21749118816.208.00138002.10EPA 4433206
NCUC36BT5D-**+TDR+ furnace: NF80X080V4B*AHRI reference: 21749119016.208.10145002.30EPA 4433208
NCHC30BT5D-**+TDR+ furnace: NF80L090S4B*AHRI reference: 21749097116.207.80134002.10EPA 4433213
NCUC36BT5D-**+TDR+ furnace: NF80L090S4B*AHRI reference: 21749097316.208.10141002.26EPA 4433215

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →