GE / AIR-SOURCE HEAT PUMP

NS17H24SA4-**A

NS17 Series · NS17H · NS17H SERIES · NS17H Series · source records, page 4

259 published source records · source checked Sep 21, 2026

SEER2 range15.4–17BTU/Wh
HSPF2 range7.8–8.2BTU/Wh
Cooling capacity22,600–24,000BTU/h

Each efficiency range summarizes published EPA records for NS17H24SA4-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 259 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.4–17259 / 259
EER2 · BTU/Wh12.5–14259 / 259
HSPF2 · BTU/Wh7.8–8.2259 / 259
Cooling capacity · BTU/h22,600–24,000259 / 259
Heating capacity at 47°F / 8.3°C · BTU/h21,200–22,600259 / 259
Heating capacity at 17°F / −8.3°C · BTU/h13,400–14,700259 / 259
Heating capacity at 5°F / −15°C · BTU/h10,200–11,500259 / 259
COP at 5°F / −15°C2–2.16259 / 259
Equipment / loop typeHP - Split System259 / 259
Refrigerant / source-reported GWPR-410A (GWP:2088)259 / 259
Compressor stagingSingle stage259 / 259
Connected capabilityNo259 / 259

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
NCHC24AT4+TDR+ furnace: NF80X060V3A-*AHRI reference: 21026207316.407.80104002.10EPA 2634876
NCUU24BP4+TDR+TXV+ furnace: NF80U090S4B-*AHRI reference: 21026203416.407.80104002.08EPA 2634878
NCUU24BP4+TDR+TXV+ furnace: NF80U070S3B-*AHRI reference: 21026203316.407.80104002.04EPA 2634881
NCUU24BP4+TDR+TXV+ furnace: NF80X080V4B-*AHRI reference: 21026203716.407.80104002.04EPA 2634889
NCUU30AP4+TDR+TXV+ furnace: NF80U045T3A-*AHRI reference: 21026204416.407.80102002.06EPA 2634890
NCUU24BP4+TDR+TXV+ furnace: NF80U090T4B-*AHRI reference: 21026203016.407.80104002.04EPA 2634891
NCUU30AP4+TDR+TXV+ furnace: NF80U070V3A-*AHRI reference: 21026205016.407.80104002.04EPA 2634895
NCUU30BP4+TDR+TXV+ furnace: NF97U070M3B-*AHRI reference: 21026206516.407.80104002.06EPA 2814824
NCUU24BP4+TDR+TXV+ furnace: NF97U070M3B-*AHRI reference: 21026204116.407.80104002.04EPA 2836542
NCUC30BT4+TDR+ furnace: NF97U070M3B-*AHRI reference: 21026214616.407.80104002.06EPA 2836602
NCDC3036CT4+TDR+ furnace: NF96D090S4C-*AHRI reference: 21335582316.408.20112002.10EPA 2841314
NCUC24BT4+TDR+ furnace: NF97U070V3BAHRI reference: 21528330516.407.80104002.04EPA 3619271
NCUC24BT5D-**+TDR+ furnace: NF97U070V3BAHRI reference: 21528330916.407.80104002.04EPA 3619273
NCUC30BT4+TDR+ furnace: NF97U070V3BAHRI reference: 21528331316.407.80104002.06EPA 3619381
NCUC30BT5D-**+TDR+ furnace: NF97U070V3BAHRI reference: 21528331816.407.80104002.06EPA 3619383
NCUU24BP4+TDR+TXV+ furnace: NF97U070V3BAHRI reference: 21528332216.407.80104002.04EPA 3619385
NCUU30BP4+TDR+TXV+ furnace: NF97U070V3BAHRI reference: 21528332616.407.80104002.06EPA 3619387
NCUC24BT4+TDR+ furnace: NF98U070M3BAHRI reference: 21543818416.407.80104002.04EPA 3627540
NCUC30BT4+TDR+ furnace: NF98U070M3BAHRI reference: 21543818516.407.80104002.06EPA 3627541
NCUU24BP4+TDR+TXV+ furnace: NF98U070M3BAHRI reference: 21543818616.407.80104002.04EPA 3627542

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →