GE / AIR-SOURCE HEAT PUMP

NS17H24SA4-**A

NS17 Series · NS17H · NS17H SERIES · NS17H Series · source records, page 3

259 published source records · source checked Sep 21, 2026

SEER2 range15.4–17BTU/Wh
HSPF2 range7.8–8.2BTU/Wh
Cooling capacity22,600–24,000BTU/h

Each efficiency range summarizes published EPA records for NS17H24SA4-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 259 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.4–17259 / 259
EER2 · BTU/Wh12.5–14259 / 259
HSPF2 · BTU/Wh7.8–8.2259 / 259
Cooling capacity · BTU/h22,600–24,000259 / 259
Heating capacity at 47°F / 8.3°C · BTU/h21,200–22,600259 / 259
Heating capacity at 17°F / −8.3°C · BTU/h13,400–14,700259 / 259
Heating capacity at 5°F / −15°C · BTU/h10,200–11,500259 / 259
COP at 5°F / −15°C2–2.16259 / 259
Equipment / loop typeHP - Split System259 / 259
Refrigerant / source-reported GWPR-410A (GWP:2088)259 / 259
Compressor stagingSingle stage259 / 259
Connected capabilityNo259 / 259

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
NCUC24AT4+TDR+ furnace: NF80X060V3A-*AHRI reference: 21026210616.407.80104002.08EPA 2471112
NCUC30AT4+TDR+ furnace: NF80U045T3A-*AHRI reference: 21026212516.407.80102002.06EPA 2471116
NCHC30AT4+TDR+ furnace: NF80U070S3A-*AHRI reference: 21026208016.408.00104002.14EPA 2471119
NCUC30BT4+TDR+ furnace: NF80U090T4B-*AHRI reference: 21026213516.408.00104002.06EPA 2471120
NCHC30BT4+TDR+ furnace: NF80X080S4B-*AHRI reference: 21026208416.407.80106002.02EPA 2471123
NCHC30AT4+TDR+ furnace: NF80U045S3A-*AHRI reference: 21026207916.408.00102002.08EPA 2471128
NCUC24BT4+TDR+ furnace: NF80U090T4B-*AHRI reference: 21026211116.407.80104002.04EPA 2471131
NCHC30BT4+TDR+ furnace: NF80U090V4B-*AHRI reference: 21026209516.407.80104002.04EPA 2471132
NCUU30BP4+TDR+TXV+ furnace: NF80U070S3B-*AHRI reference: 21026205716.407.80104002.06EPA 2471133
NCUU24AP4+TDR+TXV+ furnace: NF80U045T3A-*AHRI reference: 21026202016.407.80102002.04EPA 2472007
NCUU24AP4+TDR+TXV+ furnace: NF80X060V3A-*AHRI reference: 21026202516.407.80104002.08EPA 2472230
NCUC30BT4+TDR+ furnace: NF80X080V4B-*AHRI reference: 21026214216.407.80104002.06EPA 2634848
NCUC30AT4+TDR+ furnace: NF80U070V3A-*AHRI reference: 21026213116.407.80104002.04EPA 2634849
NCUC24BT4+TDR+ furnace: NF80U070S3B-*AHRI reference: 21026211416.407.80104002.04EPA 2634856
NCHC30AT4+TDR+ furnace: NF80L070S3A-*AHRI reference: 21026208116.408.00104002.14EPA 2634861
NCHC24AT4+TDR+ furnace: NF80U070S3A-*AHRI reference: 21026207116.407.80104002.06EPA 2634862
NCHC24AT4+TDR+ furnace: NF80U045T3A-*AHRI reference: 21026206816.407.80102002.04EPA 2634865
NCHC24AT4+TDR+ furnace: NF80L070S3A-*AHRI reference: 21026207216.407.80104002.06EPA 2634866
NCUU30BP4+TDR+TXV+ furnace: NF80U090T4B-*AHRI reference: 21026205416.408.00104002.06EPA 2634867
NCUU30BP4+TDR+TXV+ furnace: NF80X080V4B-*AHRI reference: 21026206116.407.80104002.06EPA 2634873