GE / AIR-SOURCE HEAT PUMP

NS16H24SA5-**A

NS16H SERIES · NS16H Series · source records, page 3

99 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.2BTU/Wh
Cooling capacity22,800–24,000BTU/h

Each efficiency range summarizes published EPA records for NS16H24SA5-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 99 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–1699 / 99
EER2 · BTU/Wh12–13.899 / 99
HSPF2 · BTU/Wh7.8–8.299 / 99
Cooling capacity · BTU/h22,800–24,00099 / 99
Heating capacity at 47°F / 8.3°C · BTU/h20,400–23,00099 / 99
Heating capacity at 17°F / −8.3°C · BTU/h12,900–14,70099 / 99
Heating capacity at 5°F / −15°C · BTU/h10,500–11,60099 / 99
COP at 5°F / −15°C1.96–2.299 / 99
Equipment / loop typeHP - Split System99 / 99
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)99 / 99
Compressor stagingSingle stage99 / 99
Connected capabilityNo99 / 99

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
NCU[C,U]24BT5*-**+TDR+ furnace: NF80L090S4B*AHRI reference: 21649737015.508.00108002.04EPA 3847391
NCHC30BT5*-**+TDR+ furnace: NF98U070M3B*AHRI reference: 21649744915.507.80109002.06EPA 3847413
NCU[C,U]30BT5*-**+TDR+ furnace: NF80U090T4B*AHRI reference: 21649739015.508.10114002.16EPA 3847414
NCU[C,U]30BT5*-**+TDR+ furnace: NF80L090S4B*AHRI reference: 21649739415.508.10114002.18EPA 3847415
NCU[C,U]30AT5*-**+TDR+ furnace: NF80U070V3A*AHRI reference: 21705216015.508.00114002.14EPA 3999041
NCU[C,U]30BT5*-**+TDR+ furnace: NF97U070V3B*AHRI reference: 21705216215.508.00113002.16EPA 3999042
NCHC24BT5*-**+TDR+ furnace: NF97U070V3B*AHRI reference: 21705216615.508.10106002.00EPA 3999045
NCU[C,U]30BT5*-**+TDR+ furnace: NF96U070S3B*AHRI reference: 21649739615.208.10115002.14EPA 3847225
NCDC36CT5*-**+TDR+ furnace: NF96D090S4C*AHRI reference: 21649745715.208.20113002.12EPA 3847233
NCU[C,U]30BT5*-**+TDR+ furnace: NF97X040V3B*AHRI reference: 21649739915.207.80115002.12EPA 3847235
NCU[C,U]30BT5*-**+TDR+ furnace: NF97X060V3B*AHRI reference: 21649740015.208.00113002.12EPA 3847236
NCHC24BT5*-**+TDR+ furnace: NF97U045V3B*AHRI reference: 21649742115.208.00106001.98EPA 3847261
NCHC24BT5*-**+TDR+ furnace: NF98U070M3B*AHRI reference: 21649742515.208.10107002.00EPA 3847262
NCHC30AT5*-**+TDR+ furnace: NF80X040S3A*AHRI reference: 21649742615.208.00112002.02EPA 3847263
NCHC30AT5*-**+TDR+ furnace: NF80X060S3A*AHRI reference: 21649742715.208.00112002.02EPA 3847264
NCU[C,U]24AT5*-**+TDR+ furnace: NF80U070T3A*AHRI reference: 21649735715.207.80110002.02EPA 3847266
NCHC30AT5*-**+TDR+ furnace: NF80U070T3A*AHRI reference: 21649742915.208.00113002.04EPA 3847304
NCHC30AT5*-**+TDR+ furnace: NF80U045S3A*AHRI reference: 21649743015.207.80109002.02EPA 3847305
NCHC30AT5*-**+TDR+ furnace: NF80L045S3A*AHRI reference: 21649743115.207.80109002.02EPA 3847306
NCHC30AT5*-**+TDR+ furnace: NF80U070S3A*AHRI reference: 21649743215.208.00110002.04EPA 3847307

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →