GE / AIR-SOURCE HEAT PUMP

NS16H24SA5-**A

NS16H SERIES · NS16H Series · source records, page 2

99 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.2BTU/Wh
Cooling capacity22,800–24,000BTU/h

Each efficiency range summarizes published EPA records for NS16H24SA5-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 99 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–1699 / 99
EER2 · BTU/Wh12–13.899 / 99
HSPF2 · BTU/Wh7.8–8.299 / 99
Cooling capacity · BTU/h22,800–24,00099 / 99
Heating capacity at 47°F / 8.3°C · BTU/h20,400–23,00099 / 99
Heating capacity at 17°F / −8.3°C · BTU/h12,900–14,70099 / 99
Heating capacity at 5°F / −15°C · BTU/h10,500–11,60099 / 99
COP at 5°F / −15°C1.96–2.299 / 99
Equipment / loop typeHP - Split System99 / 99
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)99 / 99
Compressor stagingSingle stage99 / 99
Connected capabilityNo99 / 99

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
NCHC24BT5*-**+TDR+ furnace: NF80U090T4B*AHRI reference: 21649741415.508.10108002.02EPA 3847355
NCHC24BT5*-**+TDR+ furnace: NF80U070S3B*AHRI reference: 21649741515.508.10106002.00EPA 3847356
NCHC24BT5*-**+TDR+ furnace: NF80L070S3B*AHRI reference: 21649741615.508.10106002.00EPA 3847357
NCHC24BT5*-**+TDR+ furnace: NF80U090S4B*AHRI reference: 21649741715.508.10107002.02EPA 3847358
NCHC24BT5*-**+TDR+ furnace: NF80L090S4B*AHRI reference: 21649741815.508.10107002.02EPA 3847359
NCHC30BT5*-**+TDR+ furnace: NF80U090T4B*AHRI reference: 21649743815.508.00110002.08EPA 3847362
NCHC30BT5*-**+TDR+ furnace: NF80U070S3B*AHRI reference: 21649743915.508.00109002.08EPA 3847363
NCHC30BT5*-**+TDR+ furnace: NF80L070S3B*AHRI reference: 21649744015.508.00109002.08EPA 3847364
NCHC30BT5*-**+TDR+ furnace: NF80U090S4B*AHRI reference: 21649744115.508.10110002.10EPA 3847365
NCHC30BT5*-**+TDR+ furnace: NF80L090S4B*AHRI reference: 21649744215.508.10110002.10EPA 3847366
NCHC30BT5*-**+TDR+ furnace: NF96U070S3B*AHRI reference: 21649744415.508.00111002.06EPA 3847367
NCU[C,U]30AT5*-**+TDR+ furnace: NF80U045S3A*AHRI reference: 21649738215.507.80112002.14EPA 3847375
NCU[C,U]30AT5*-**+TDR+ furnace: NF80L045S3A*AHRI reference: 21649738315.507.80112002.14EPA 3847376
NCU[C,U]30AT5*-**+TDR+ furnace: NF80U070S3A*AHRI reference: 21649738415.508.00113002.14EPA 3847377
NCU[C,U]30AT5*-**+TDR+ furnace: NF80L070S3A*AHRI reference: 21649738515.508.00113002.14EPA 3847378
NCU[C,U]30AT5*-**+TDR+ furnace: NF80X060V3A*AHRI reference: 21649738615.508.00113002.14EPA 3847379
NCU[C,U]24BT5*-**+TDR+ furnace: NF80U090T4B*AHRI reference: 21649736615.508.00109002.04EPA 3847387
NCU[C,U]24BT5*-**+TDR+ furnace: NF80U070S3B*AHRI reference: 21649736715.507.80108002.04EPA 3847388
NCU[C,U]24BT5*-**+TDR+ furnace: NF80L070S3B*AHRI reference: 21649736815.507.80108002.04EPA 3847389
NCU[C,U]24BT5*-**+TDR+ furnace: NF80U090S4B*AHRI reference: 21649736915.508.00108002.04EPA 3847390

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →