NS18H60HA5***
Connect · source records, page 12
352 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for NS18H60HA5***. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 352 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–18.3 | 352 / 352 |
| EER2 · BTU/Wh | 9.6–11.7 | 352 / 352 |
| HSPF2 · BTU/Wh | 8.1–9.6 | 352 / 352 |
| Cooling capacity · BTU/h | 42,500–55,500 | 352 / 352 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 47,000–56,500 | 352 / 352 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 38,000–45,000 | 352 / 352 |
| Heating capacity at 5°F / −15°C · BTU/h | 39,000–45,000 | 352 / 352 |
| COP at 5°F / −15°C | 1.75–1.95 | 352 / 352 |
| Equipment / loop type | HP - Split System | 352 / 352 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 352 / 352 |
| Compressor staging | Continuously variable | 352 / 352 |
| Connected capability | No | 352 / 352 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
NCUC48CT5****+TDR+ furnace: NF80L110S5C***Cold climate designationAHRI reference: 217124160 | 16.15 | 8.50 | 39500 | 1.80 | EPA 4003637 → |
NCHC48CT5****+TDR+ furnace: NF96U090S4C***Cold climate designationAHRI reference: 217124202 | 16.15 | 8.50 | 39500 | 1.80 | EPA 4004674 → |
NCHC51CT5****+TDR+ furnace: NF80X100V5C***Cold climate designationAHRI reference: 217124231 | 16.15 | 8.50 | 41000 | 1.85 | EPA 4004703 → |
NCUC48CT5****+TDR+ furnace: NF80U110T3BF***Cold climate designationAHRI reference: 217313728 | 16.15 | 8.50 | 39500 | 1.80 | EPA 4028858 → |
NCUC48CT5****+TDR+ furnace: NF96U090S5CF***Cold climate designationAHRI reference: 217313759 | 16.15 | 8.50 | 40000 | 1.80 | EPA 4028873 → |
NCUC48CT5****+TDR+ furnace: NF93U110S5CF***Cold climate designationAHRI reference: 217313761 | 16.15 | 8.50 | 39500 | 1.80 | EPA 4028874 → |
NCDC42BT5****+TDR+ furnace: NF97D070T4BF***Cold climate designationAHRI reference: 217313913 | 16.15 | 9.00 | 39500 | 1.85 | EPA 4029000 → |
NCHC48CT5****+TDR+ furnace: NF97U090T4CF***Cold climate designationAHRI reference: 217313875 | 16.15 | 8.50 | 39500 | 1.80 | EPA 4029020 → |
NCHC48CT5****+TDR+ furnace: NF80U110V5CF***Cold climate designationAHRI reference: 217313898 | 16.15 | 8.50 | 40000 | 1.80 | EPA 4029030 → |
NCDC5060CT5****+TDR+ furnace: NF80D090V5CF***Cold climate designationAHRI reference: 217314019 | 16.15 | 8.50 | 40500 | 1.90 | EPA 4029056 → |
NCDC60DT5****+TDR+ furnace: NF97D110T5CF***Cold climate designationAHRI reference: 217314045 | 16.15 | 8.50 | 40500 | 1.90 | EPA 4029066 → |
NCHC60DT5****+TDR+ furnace: NF96U090V5C***Cold climate designationAHRI reference: 217611978 | 16.15 | 8.10 | 40000 | 1.80 | EPA 4518291 → |
NCHC42CT5****+TDR+ furnace: NF97U090V5C***Cold climate designationAHRI reference: 216743602 | 16.10 | 8.50 | 40000 | 1.80 | EPA 3893300 → |
NCHC48CT5****+TDR+ furnace: NF98U110M5C***Cold climate designationAHRI reference: 217124208 | 16.10 | 8.50 | 40000 | 1.80 | EPA 4004680 → |
NCHC42CT5****+TDR+ furnace: NF96U090V5C***Cold climate designationAHRI reference: 217177722 | 16.10 | 8.50 | 40000 | 1.80 | EPA 4006880 → |
NCUC48CT5****+TDR+ furnace: NF97U110T5CF***Cold climate designationAHRI reference: 217313757 | 16.10 | 8.50 | 40000 | 1.80 | EPA 4028871 → |
NCHC42CT5****+TDR+ furnace: NF96U110V5CF***Cold climate designationAHRI reference: 217313856 | 16.10 | 8.50 | 40000 | 1.80 | EPA 4028992 → |
NCDC42BT5****+TDR+ furnace: NF96D070V4BF***Cold climate designationAHRI reference: 217313916 | 16.10 | 9.00 | 39500 | 1.85 | EPA 4029001 → |
NCHC51CT5****+TDR+ furnace: NF96U090S5CF***Cold climate designationAHRI reference: 217314006 | 16.10 | 8.50 | 40500 | 1.85 | EPA 4029048 → |
NCHC51CT5****+TDR+ furnace: NF97U110T5CF***Cold climate designationAHRI reference: 217314004 | 16.10 | 8.50 | 40500 | 1.85 | EPA 4029049 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.