NS18H60HA5***
Connect · source records, page 11
352 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for NS18H60HA5***. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 352 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–18.3 | 352 / 352 |
| EER2 · BTU/Wh | 9.6–11.7 | 352 / 352 |
| HSPF2 · BTU/Wh | 8.1–9.6 | 352 / 352 |
| Cooling capacity · BTU/h | 42,500–55,500 | 352 / 352 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 47,000–56,500 | 352 / 352 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 38,000–45,000 | 352 / 352 |
| Heating capacity at 5°F / −15°C · BTU/h | 39,000–45,000 | 352 / 352 |
| COP at 5°F / −15°C | 1.75–1.95 | 352 / 352 |
| Equipment / loop type | HP - Split System | 352 / 352 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 352 / 352 |
| Compressor staging | Continuously variable | 352 / 352 |
| Connected capability | No | 352 / 352 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
NCDC5060CT5****+TDR+ furnace: NF80D110V5CF***Cold climate designationAHRI reference: 217314022 | 16.35 | 8.50 | 40500 | 1.90 | EPA 4029055 → |
NCUC48CT5****+TDR+ furnace: NF80X100S5C***Cold climate designationAHRI reference: 217124159 | 16.30 | 8.50 | 40000 | 1.80 | EPA 4003635 → |
NCHC48BT5****+TDR+ furnace: NF80X080S4B***Cold climate designationAHRI reference: 217124197 | 16.30 | 9.00 | 39500 | 1.80 | EPA 4004669 → |
NCHC51CT5****+TDR+ furnace: NF80L110S5C***Cold climate designationAHRI reference: 217124232 | 16.30 | 8.50 | 40000 | 1.85 | EPA 4004704 → |
NCHC51CT5****+TDR+ furnace: NF80U110T5C***Cold climate designationAHRI reference: 217124233 | 16.30 | 8.50 | 40000 | 1.85 | EPA 4004706 → |
NCDC48CT5****+TDR+ furnace: NF97D110T5CF***Cold climate designationAHRI reference: 217313932 | 16.30 | 9.00 | 39500 | 1.90 | EPA 4029035 → |
NCDC60DT5****+TDR+ furnace: NF80D090V5CF***Cold climate designationAHRI reference: 217314035 | 16.30 | 8.50 | 40500 | 1.90 | EPA 4029061 → |
NCUC49CT5****+TDR+ furnace: NF96U110S5C***Cold climate designationAHRI reference: 217124180 | 16.25 | 8.50 | 39000 | 1.85 | EPA 4004651 → |
NCUC49CT5****+TDR+ furnace: NF95X100S5C***Cold climate designationAHRI reference: 217124179 | 16.25 | 9.00 | 39500 | 1.85 | EPA 4004652 → |
NCHC42BT5****+TDR+ furnace: NF80X080S4B***Cold climate designationAHRI reference: 217124182 | 16.25 | 9.00 | 39000 | 1.90 | EPA 4004654 → |
NCHC51CT5****+TDR+ furnace: NF93U110S5CF***Cold climate designationAHRI reference: 217314009 | 16.25 | 8.50 | 40500 | 1.85 | EPA 4029051 → |
NCDC60DT5****+TDR+ furnace: NF96D110S5CF***Cold climate designationAHRI reference: 217314047 | 16.25 | 8.50 | 41000 | 1.90 | EPA 4029067 → |
NCHC42CT5****+TDR+ furnace: NF80U090S5C***Cold climate designationAHRI reference: 217124192 | 16.20 | 8.50 | 39500 | 1.80 | EPA 4004663 → |
NCHC42CT5****+TDR+ furnace: NF80U110S5C***Cold climate designationAHRI reference: 217124193 | 16.20 | 8.50 | 40000 | 1.80 | EPA 4004666 → |
NCHC42CT5****+TDR+ furnace: NF80U110S5CF***Cold climate designationAHRI reference: 217313844 | 16.20 | 8.50 | 40000 | 1.80 | EPA 4028986 → |
NCHC48CT5****+TDR+ furnace: NF96U090S4CF***Cold climate designationAHRI reference: 217313873 | 16.20 | 8.50 | 39500 | 1.80 | EPA 4029019 → |
NCHC48CT5****+TDR+ furnace: NF93U090S4CF***Cold climate designationAHRI reference: 217313883 | 16.20 | 8.50 | 40000 | 1.80 | EPA 4029023 → |
NCDC5060CT5****+TDR+ furnace: NF96D110S5CF***Cold climate designationAHRI reference: 217314031 | 16.20 | 8.50 | 40500 | 1.90 | EPA 4029057 → |
NAS60E1TB5****Cold climate designationAHRI reference: 218635944 | 16.20 | 8.90 | 43000 | 1.80 | EPA 4661148 → |
NCUC48CT5****+TDR+ furnace: NF80U110T5C***Cold climate designationAHRI reference: 217124161 | 16.15 | 8.50 | 39500 | 1.80 | EPA 4003636 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →