RD18AY24AJVC
K-SERIES · K-Series · source records, page 4
144 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for RD18AY24AJVC. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 144 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 17–19 | 144 / 144 |
| EER2 · BTU/Wh | 10–12 | 144 / 144 |
| HSPF2 · BTU/Wh | 8.1–10 | 144 / 144 |
| Cooling capacity · BTU/h | 20,800–21,400 | 144 / 144 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 20,600–24,000 | 144 / 144 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 17,900–19,800 | 144 / 144 |
| Heating capacity at 5°F / −15°C · BTU/h | 16,800–18,400 | 144 / 144 |
| COP at 5°F / −15°C | 1.9–2 | 144 / 144 |
| Equipment / loop type | HP - Split System | 144 / 144 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 144 / 144 |
| Compressor staging | Continuously variable | 144 / 144 |
| Connected capability | Yes | 144 / 144 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
TCFY2417STANM+ furnace: FR801V0504A17UHNCold climate designationAHRI reference: 217562049 | 18.00 | 10.00 | 18200 | 2.00 | EPA 4470926 → |
TCFY2417STANM+ furnace: FR801V0504A17UHSCold climate designationAHRI reference: 217562050 | 18.00 | 10.00 | 18200 | 2.00 | EPA 4470927 → |
TCFY2417STANM+ furnace: FR801V0704A17UHCold climate designationAHRI reference: 217562051 | 18.00 | 10.00 | 18200 | 2.00 | EPA 4470928 → |
TCFY2417STANM+ furnace: FR801V0504A17UHUCold climate designationAHRI reference: 217562053 | 18.00 | 10.00 | 18300 | 2.00 | EPA 4470929 → |
TCFY2417STANM+ furnace: FR801V1004A17UHCold climate designationAHRI reference: 217562056 | 18.00 | 10.00 | 18100 | 2.00 | EPA 4470932 → |
TCFY2417STANM+ furnace: FR802V0504A17UHCold climate designationAHRI reference: 217562058 | 18.00 | 10.00 | 18200 | 2.00 | EPA 4470934 → |
TCFY2417STANM+ furnace: FR921V0603A17M4SCold climate designationAHRI reference: 217562063 | 18.00 | 10.00 | 18300 | 2.00 | EPA 4470939 → |
TCFY2417STANM+ furnace: FR951V0603A17UHCold climate designationAHRI reference: 217562064 | 18.00 | 10.00 | 18300 | 2.00 | EPA 4470940 → |
TCFY2417STANM+ furnace: FR951V0403A17M4SCold climate designationAHRI reference: 217562065 | 18.00 | 10.00 | 18200 | 2.00 | EPA 4470941 → |
TCFY2417STANM+ furnace: FR951V0403A17UHCold climate designationAHRI reference: 217562067 | 18.00 | 10.00 | 18400 | 2.00 | EPA 4470943 → |
TCFY2417STANM+ furnace: FR962V0403A17M4SCold climate designationAHRI reference: 217562068 | 18.00 | 10.00 | 18200 | 2.00 | EPA 4470944 → |
TCFY2417STANM+ furnace: FR962V0603A17M4SCold climate designationAHRI reference: 217562069 | 18.00 | 10.00 | 18300 | 2.00 | EPA 4470946 → |
TCFY2417STANM+ furnace: FR921V0403A17M4SCold climate designationAHRI reference: 217562071 | 18.00 | 10.00 | 18200 | 2.00 | EPA 4470948 → |
TCFY2417STANM+ furnace: FR951V0603A17M4SCold climate designationAHRI reference: 217562072 | 18.00 | 10.00 | 18300 | 2.00 | EPA 4470949 → |
TCFY2417MTANM+ furnace: FR801V0503A14UHCold climate designationAHRI reference: 217562074 | 18.00 | 9.50 | 17000 | 1.90 | EPA 4470950 → |
TCFY2417MTANM+ furnace: FR802V0503A14UHCold climate designationAHRI reference: 217562076 | 18.00 | 9.50 | 17000 | 1.90 | EPA 4470952 → |
TCFY2417MTANM+ furnace: FR802V0503A14DZCold climate designationAHRI reference: 217562077 | 18.00 | 9.50 | 17000 | 1.90 | EPA 4470953 → |
TCFY2417MTANM+ furnace: FR801V0503A14DZCold climate designationAHRI reference: 217562082 | 18.00 | 9.50 | 17000 | 1.90 | EPA 4470958 → |
TCFY2417MTANM+ furnace: FR98MV0703A17UPCold climate designationAHRI reference: 217562086 | 18.00 | 8.10 | 17000 | 1.90 | EPA 4470962 → |
TCFY2417MTANM+ furnace: FR97MV0603A17DHCold climate designationAHRI reference: 217562088 | 18.00 | 9.50 | 17000 | 1.90 | EPA 4470964 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →