Heating performance & equipment details
Ranges include the 144 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 17–19 | 144 / 144 |
| EER2 · BTU/Wh | 10–12 | 144 / 144 |
| HSPF2 · BTU/Wh | 8.1–10 | 144 / 144 |
| Cooling capacity · BTU/h | 20,800–21,400 | 144 / 144 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 20,600–24,000 | 144 / 144 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 17,900–19,800 | 144 / 144 |
| Heating capacity at 5°F / −15°C · BTU/h | 16,800–18,400 | 144 / 144 |
| COP at 5°F / −15°C | 1.9–2 | 144 / 144 |
| Equipment / loop type | HP - Split System | 144 / 144 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 144 / 144 |
| Compressor staging | Continuously variable | 144 / 144 |
| Connected capability | Yes | 144 / 144 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
RCFY2417MTANM+ furnace: FR801V0503A14DZCold climate designationAHRI reference: 216819083 | 18.00 | 9.50 | 17000 | 1.90 | EPA 4028317 → |
RCFY2417MTANM+ furnace: FR97MV0603A17DHCold climate designationAHRI reference: 216819129 | 18.00 | 9.50 | 17000 | 1.90 | EPA 4028395 → |
RCFY2417MTANM+ furnace: FR98MV0603A17UPCold climate designationAHRI reference: 216819136 | 18.00 | 9.50 | 17000 | 1.90 | EPA 4028398 → |
RCFY2417MTANM+ furnace: FR97MV0703A17DHCold climate designationAHRI reference: 216819149 | 18.00 | 9.50 | 17000 | 1.90 | EPA 4028402 → |
RCFY2421MTANM+ furnace: FR97MV0603A17DHCold climate designationAHRI reference: 216819357 | 18.00 | 9.50 | 17000 | 1.90 | EPA 4028406 → |
RCFY2421MTANM+ furnace: FR98MV0703A17UPCold climate designationAHRI reference: 216819235 | 18.00 | 8.10 | 17000 | 1.90 | EPA 4028457 → |
RCFY2421MTANM+ furnace: FR97MV1005A21DHCold climate designationAHRI reference: 216819248 | 18.00 | 8.10 | 17000 | 1.90 | EPA 4028458 → |
RCFY2417STANM+ furnace: FR801V0504A17UHNCold climate designationAHRI reference: 217176002 | 18.00 | 10.00 | 18200 | 2.00 | EPA 4439631 → |
RCFY2417STANM+ furnace: FR801V0504A17UHSCold climate designationAHRI reference: 217176005 | 18.00 | 10.00 | 18200 | 2.00 | EPA 4439634 → |
RCFY2417STANM+ furnace: FR801V0704A17UHCold climate designationAHRI reference: 217176009 | 18.00 | 10.00 | 18200 | 2.00 | EPA 4439638 → |
RCFY2417STANM+ furnace: FR801V0504A17UHUCold climate designationAHRI reference: 217176021 | 18.00 | 10.00 | 18300 | 2.00 | EPA 4439646 → |
RCFY2417STANM+ furnace: FR802V0504A17UHCold climate designationAHRI reference: 217176031 | 18.00 | 10.00 | 18200 | 2.00 | EPA 4439649 → |
RCFY2417STANM+ furnace: FR921V0603A17M4Cold climate designationAHRI reference: 217176053 | 18.00 | 10.00 | 18300 | 2.00 | EPA 4439661 → |
RCFY2417STANM+ furnace: FR951V0603A17UHCold climate designationAHRI reference: 217176054 | 18.00 | 10.00 | 18300 | 2.00 | EPA 4439662 → |
RCFY2417STANM+ furnace: FR951V0403A17M4Cold climate designationAHRI reference: 217176060 | 18.00 | 10.00 | 18200 | 2.00 | EPA 4439668 → |
RCFY2417STANM+ furnace: FR951V0403A17UHCold climate designationAHRI reference: 217176067 | 18.00 | 10.00 | 18400 | 2.00 | EPA 4439675 → |
RCFY2417STANM+ furnace: FR962V0403A17M4Cold climate designationAHRI reference: 217176069 | 18.00 | 10.00 | 18200 | 2.00 | EPA 4439677 → |
RCFY2417STANM+ furnace: FR962V0603A17M4Cold climate designationAHRI reference: 217176070 | 18.00 | 10.00 | 18300 | 2.00 | EPA 4439678 → |
RCFY2417STANM+ furnace: FR921V0403A17M4Cold climate designationAHRI reference: 217176072 | 18.00 | 10.00 | 18200 | 2.00 | EPA 4439680 → |
RCFY2417STANM+ furnace: FR951V0603A17M4Cold climate designationAHRI reference: 217176077 | 18.00 | 10.00 | 18300 | 2.00 | EPA 4439685 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.