Fraser-Johnston / AIR-SOURCE HEAT PUMP

XH660E2S11

LX SERIES · source records, page 4

222 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity52,500–55,000BTU/h

Each efficiency range summarizes published EPA records for XH660E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 222 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16222 / 222
EER2 · BTU/Wh11–12222 / 222
HSPF2 · BTU/Wh7.8–8.5222 / 222
Cooling capacity · BTU/h52,500–55,000222 / 222
Heating capacity at 47°F / 8.3°C · BTU/h56,000–60,000222 / 222
Heating capacity at 17°F / −8.3°C · BTU/h37,800–39,500222 / 222
Heating capacity at 5°F / −15°C · BTU/h30,000–32,600222 / 222
COP at 5°F / −15°C2–2.38222 / 222
Equipment / loop typeHP - Split System222 / 222
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)222 / 222
Compressor stagingTwo-stage222 / 222
Connected capabilityNo222 / 222

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTM60D5CHS1+ furnace: Z8ES130D20LMPS1AHRI reference: 21701865015.208.10314002.28EPA 4571588 →
CTM60C5CHS1+ furnace: Z8ES120C16LMPS1AHRI reference: 21701864815.208.10314002.26EPA 4571589 →
CTM60C5CHS1+ furnace: Z8ES100C16LMPS1AHRI reference: 21701864715.208.10316002.26EPA 4571590 →
CTM60C5CHS1+ furnace: Z8ES100C20LMPS1AHRI reference: 21701864615.208.10312002.28EPA 4571591 →
CTM60C5CHS1+ furnace: Z8ES080C20LMPS1AHRI reference: 21701864515.208.10316002.26EPA 4571592 →
CTM60D5CHS1+ furnace: Z9ET120D20SMPS1AHRI reference: 21701864415.208.10316002.26EPA 4571593 →
CTM60D5CJS1+ furnace: Z9ET120D20SMPS1AHRI reference: 21701864315.208.10324002.32EPA 4571594 →
CTM60C5CHS1+ furnace: Z9ET100C20SMPS1AHRI reference: 21701864215.208.10320002.24EPA 4571595 →
CTM60C5CHS1+ furnace: Z8ES080C20SMPS1AHRI reference: 21701864115.208.10316002.26EPA 4571596 →
CTM60C5CHS1+ furnace: Z8ES120C16SMPS1AHRI reference: 21701864015.208.10314002.26EPA 4571597 →
CTM60C5CHS1+ furnace: Z8ES100C20SMPS1AHRI reference: 21701863915.208.10312002.28EPA 4571598 →
CTM60C5CHS1+ furnace: Z8ES100C16SMPS1AHRI reference: 21701863815.208.10316002.26EPA 4571599 →
CTM60D5CHS1+ furnace: Z8ES130D20SMPS1AHRI reference: 21701863715.208.10314002.28EPA 4571600 →
CTM60C5CHS1+ furnace: Z8ES120C20SMPS1AHRI reference: 21701863515.208.10316002.26EPA 4571601 →
CTM60C5CHS1+ furnace: Z8ET100C16LMPS1AHRI reference: 21701863415.208.10314002.26EPA 4571602 →
CTM60C5CHS1+ furnace: Z8ET120C20LMPS1AHRI reference: 21701863315.208.10312002.28EPA 4571603 →
CTM60C5CHS1+ furnace: Z8ET100C20LMPS1AHRI reference: 21701863215.208.10312002.28EPA 4571604 →
CTM60C5CHS1+JMVT17CC2N1AHRI reference: 21701863115.208.10310002.30EPA 4571605 →
CTM60D5CJS1+JMET18DS2N1AHRI reference: 21701863015.208.50320002.36EPA 4571606 →
CTM60C5CHS1+JME16C2SN1AHRI reference: 21701862915.208.10312002.30EPA 4571607 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →