XH660E2S11
LX SERIES · source records, page 2
222 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for XH660E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 222 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 222 / 222 |
| EER2 · BTU/Wh | 11–12 | 222 / 222 |
| HSPF2 · BTU/Wh | 7.8–8.5 | 222 / 222 |
| Cooling capacity · BTU/h | 52,500–55,000 | 222 / 222 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 56,000–60,000 | 222 / 222 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 37,800–39,500 | 222 / 222 |
| Heating capacity at 5°F / −15°C · BTU/h | 30,000–32,600 | 222 / 222 |
| COP at 5°F / −15°C | 2–2.38 | 222 / 222 |
| Equipment / loop type | HP - Split System | 222 / 222 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 222 / 222 |
| Compressor staging | Two-stage | 222 / 222 |
| Connected capability | No | 222 / 222 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
JHE60D5CJ2SS2AHRI reference: 218457235 | 16.00 | 8.50 | 32000 | 2.38 | EPA 4639451 → |
JHE60C5CH2SS2AHRI reference: 218457229 | 16.00 | 8.10 | 31400 | 2.28 | EPA 4639457 → |
CTM60D5CJS2+ furnace: Z8ES130D20LMPS1AHRI reference: 218529071 | 16.00 | 8.10 | 32400 | 2.34 | EPA 4647051 → |
CTM60D5CJS2+ furnace: Z8ES130D20SMPS1AHRI reference: 218529067 | 16.00 | 8.10 | 32400 | 2.34 | EPA 4647055 → |
CTM60D5CJS2+JMVT20DC2N1AHRI reference: 218529063 | 16.00 | 8.50 | 32000 | 2.36 | EPA 4647059 → |
CTM60D5CJS2+JMC20D2SN1AHRI reference: 218529059 | 16.00 | 8.50 | 32000 | 2.36 | EPA 4647063 → |
CTF60D5CJS2+ furnace: Z8ES130D20LMPS1AHRI reference: 218528823 | 16.00 | 8.50 | 32200 | 2.36 | EPA 4647287 → |
CTF60D5CJS2+ furnace: Z8ES130D20SMPS1AHRI reference: 218528819 | 16.00 | 8.50 | 32200 | 2.36 | EPA 4647291 → |
CTF60D5CJS2+JMC20D2SN1AHRI reference: 218528815 | 16.00 | 8.50 | 32000 | 2.38 | EPA 4647295 → |
CTF60D5CJS2+JMVT20DC2N1AHRI reference: 218528811 | 16.00 | 8.50 | 32000 | 2.38 | EPA 4647299 → |
CTF60D5CJS2+JME18D2SN2AHRI reference: 218638375 | 16.00 | 8.50 | 32000 | 2.36 | EPA 4664300 → |
CTM60C5CHS1+ furnace: Z8VT080C16SMPC1AHRI reference: 217445295 | 15.20 | 8.10 | 31600 | 2.26 | EPA 4045353 → |
CTF60C5CHS1+ furnace: Z8VT100C16SMPC1AHRI reference: 217445296 | 15.20 | 8.10 | 31800 | 2.26 | EPA 4045354 → |
CTF60C5CHS1+ furnace: Z8VT120C20SMPC1AHRI reference: 217445297 | 15.20 | 8.10 | 31800 | 2.26 | EPA 4045355 → |
CTF60C5CHS1+ furnace: Z8VT100C20SMPC1AHRI reference: 217445298 | 15.20 | 8.10 | 31600 | 2.26 | EPA 4045356 → |
CTM60C5CHS1+ furnace: Z8VT120C20SMPC1AHRI reference: 217445299 | 15.20 | 8.10 | 32400 | 2.24 | EPA 4045357 → |
CTM60C5CHS1+ furnace: Z8VT100C20SMPC1AHRI reference: 217445300 | 15.20 | 8.10 | 31600 | 2.26 | EPA 4045358 → |
CTF60C5CHS1+ furnace: Z8VT080C16SMPC1AHRI reference: 217445301 | 15.20 | 8.10 | 31600 | 2.26 | EPA 4045359 → |
CTM60C5CHS1+ furnace: Z8VT100C16SMPC1AHRI reference: 217445302 | 15.20 | 8.10 | 31400 | 2.26 | EPA 4045360 → |
CTM60D5CJS1+ furnace: TP9C120D20MP13AHRI reference: 217994401 | 15.20 | 8.00 | 31400 | 2.00 | EPA 4570867 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →