Fraser-Johnston / AIR-SOURCE HEAT PUMP

XH660E2S11

LX SERIES · source records, page 10

222 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity52,500–55,000BTU/h

Each efficiency range summarizes published EPA records for XH660E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 222 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16222 / 222
EER2 · BTU/Wh11–12222 / 222
HSPF2 · BTU/Wh7.8–8.5222 / 222
Cooling capacity · BTU/h52,500–55,000222 / 222
Heating capacity at 47°F / 8.3°C · BTU/h56,000–60,000222 / 222
Heating capacity at 17°F / −8.3°C · BTU/h37,800–39,500222 / 222
Heating capacity at 5°F / −15°C · BTU/h30,000–32,600222 / 222
COP at 5°F / −15°C2–2.38222 / 222
Equipment / loop typeHP - Split System222 / 222
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)222 / 222
Compressor stagingTwo-stage222 / 222
Connected capabilityNo222 / 222

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTF60D5CJS2+ furnace: Z9ET120D20SMPS1AHRI reference: 21852882915.208.10324002.34EPA 4647281
CTF60D5CHS2+JMC20D2SN1AHRI reference: 21852879715.208.10310002.30EPA 4647307
CTF60D5CHS2+JMVT20DC2N1AHRI reference: 21852878915.208.10310002.30EPA 4647315
CTF60D5CHS2+ furnace: Z8ES130D20LMPS1AHRI reference: 21852877315.208.10314002.28EPA 4647331
CTF60D5CHS2+ furnace: Z8ES130D20SMPS1AHRI reference: 21852876915.208.10314002.28EPA 4647335
CTF60D5CHS2+ furnace: Z9ES120D20SMPS1AHRI reference: 21852875715.208.10316002.26EPA 4647347
CTF60D5CHS2+ furnace: Z9ET120D20SMPS1AHRI reference: 21852874915.208.10316002.26EPA 4647355
CTF60D5CHS2+ furnace: TP9C120D20MP13AHRI reference: 21852872115.208.00304002.00EPA 4647371
CTF60D5CHS2+ furnace: TM9V120D20MP12AHRI reference: 21852871715.208.00304002.00EPA 4647375
CTF60C5CHS2+ furnace: Z8ET120C20LMPS1AHRI reference: 21852871315.208.10312002.28EPA 4647379
CTF60C5CHS2+ furnace: Z9ET100C16SMPS1AHRI reference: 21852870915.208.00318002.24EPA 4647383
CTF60C5CHS2+ furnace: Z9ES100C20SMPS1AHRI reference: 21852870315.208.10316002.26EPA 4647389
CTF60C5CHS2+ furnace: Z8ES100C20LMPS1AHRI reference: 21852869715.208.10312002.28EPA 4647395
CTF60C5CHS2+ furnace: Z8ES100C20SMPS1AHRI reference: 21852869315.208.10312002.28EPA 4647399
CTF60C5CHS2+ furnace: Z9ET080C16SMPS1AHRI reference: 21852868915.208.00318002.24EPA 4647403
CTF60C5CHS2+ furnace: Z9ES080C16SMPS1AHRI reference: 21852868315.208.00318002.24EPA 4647409
CTF60C5CHS2+ furnace: Z8ET100C16LMPS1AHRI reference: 21852867915.208.10314002.26EPA 4647413
CTF60C5CHS2+ furnace: Z8ES080C20LMPS1AHRI reference: 21852867315.208.10316002.26EPA 4647419
CTF60C5CHS2+ furnace: Z8ES080C20SMPS1AHRI reference: 21852866915.208.10316002.26EPA 4647423
CTF60C5CHS2+ furnace: Z9ES080C20SMPS1AHRI reference: 21852866315.208.10320002.22EPA 4647429

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →