XH648E2S11
LX SERIES · source records, page 22
516 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for XH648E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 516 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 516 / 516 |
| EER2 · BTU/Wh | 11.7–12 | 516 / 516 |
| HSPF2 · BTU/Wh | 7.8–8.1 | 516 / 516 |
| Cooling capacity · BTU/h | 45,000–49,000 | 516 / 516 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 46,000–50,000 | 516 / 516 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 31,800–34,000 | 516 / 516 |
| Heating capacity at 5°F / −15°C · BTU/h | 25,000–27,800 | 516 / 516 |
| COP at 5°F / −15°C | 2–2.4 | 516 / 516 |
| Equipment / loop type | HP - Split System | 516 / 516 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 516 / 516 |
| Compressor staging | Two-stage | 516 / 516 |
| Connected capability | No | 516 / 516 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTU60C5XGS2+JMVT17CC2N1+TXVAHRI reference: 218529203 | 16.00 | 8.10 | 27200 | 2.28 | EPA 4649615 → |
CTF60C5CGS2+JMVT17CC2N1AHRI reference: 218529199 | 16.00 | 8.10 | 27200 | 2.28 | EPA 4649619 → |
CTU60C5XGS2+TXV+ furnace: Z9ES080C20SMPS1AHRI reference: 218529193 | 16.00 | 8.10 | 27800 | 2.22 | EPA 4649625 → |
CTF60C5CGS2+ furnace: Z9ES080C20SMPS1AHRI reference: 218529187 | 16.00 | 8.10 | 27800 | 2.22 | EPA 4649631 → |
CTU60C5XGS2+TXV+ furnace: Z9ET100C16SMPS1AHRI reference: 218529183 | 16.00 | 8.10 | 27400 | 2.22 | EPA 4649635 → |
CTF60C5CGS2+ furnace: Z9ET100C16SMPS1AHRI reference: 218529179 | 16.00 | 8.10 | 27400 | 2.22 | EPA 4649639 → |
CTU60C5XGS2+TXV+ furnace: Z8VT120C20SMPC1AHRI reference: 218529175 | 16.00 | 8.10 | 27200 | 2.26 | EPA 4649643 → |
CTF60C5CGS2+ furnace: Z8VT120C20SMPC1AHRI reference: 218529171 | 16.00 | 8.10 | 27200 | 2.26 | EPA 4649647 → |
CTU60C5XGS2+TXV+ furnace: Z8VT080C16SMPC1AHRI reference: 218529167 | 16.00 | 8.10 | 27600 | 2.26 | EPA 4649651 → |
CTF60C5CGS2+ furnace: Z8VT080C16SMPC1AHRI reference: 218529163 | 16.00 | 8.10 | 27600 | 2.26 | EPA 4649655 → |
CTU60C5XGS2+TXV+ furnace: Z8VT100C20SMPC1AHRI reference: 218529159 | 16.00 | 8.10 | 27400 | 2.26 | EPA 4649659 → |
CTF60C5CGS2+ furnace: Z8VT100C20SMPC1AHRI reference: 218529155 | 16.00 | 8.10 | 27400 | 2.26 | EPA 4649663 → |
CTU60C5XGS2+TXV+ furnace: Z8VT100C16SMPC1AHRI reference: 218529151 | 16.00 | 8.10 | 27400 | 2.26 | EPA 4649667 → |
CTF60C5CGS2+ furnace: Z8VT100C16SMPC1AHRI reference: 218529147 | 16.00 | 8.10 | 27400 | 2.26 | EPA 4649671 → |
CTM60C5CHS2+JME12C2SN2AHRI reference: 218638399 | 16.00 | 8.10 | 26400 | 2.34 | EPA 4664276 → |
CTM60C5CHS2+JME16C2SN2AHRI reference: 218638393 | 16.00 | 8.10 | 27000 | 2.34 | EPA 4664282 → |
CTF60D5CHS2+JME18D2SN2AHRI reference: 218638381 | 16.00 | 8.10 | 26800 | 2.36 | EPA 4664294 → |
CTF60C5CHS2+JME12C2SN2AHRI reference: 218638333 | 16.00 | 8.10 | 26400 | 2.34 | EPA 4664306 → |
CTM60D5CGS2+JME18D2SN2AHRI reference: 218638327 | 16.00 | 8.10 | 27200 | 2.28 | EPA 4664312 → |
CTU60C5XGS2+JME12C2SN2+TXVAHRI reference: 218638321 | 16.00 | 8.10 | 26800 | 2.26 | EPA 4664318 → |