XH648E2S11
LX SERIES · source records, page 13
516 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for XH648E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 516 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 516 / 516 |
| EER2 · BTU/Wh | 11.7–12 | 516 / 516 |
| HSPF2 · BTU/Wh | 7.8–8.1 | 516 / 516 |
| Cooling capacity · BTU/h | 45,000–49,000 | 516 / 516 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 46,000–50,000 | 516 / 516 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 31,800–34,000 | 516 / 516 |
| Heating capacity at 5°F / −15°C · BTU/h | 25,000–27,800 | 516 / 516 |
| COP at 5°F / −15°C | 2–2.4 | 516 / 516 |
| Equipment / loop type | HP - Split System | 516 / 516 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 516 / 516 |
| Compressor staging | Two-stage | 516 / 516 |
| Connected capability | No | 516 / 516 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTF60C5CHS1+ furnace: Z9ES080C16SMPS1AHRI reference: 217019997 | 16.00 | 7.80 | 26800 | 2.30 | EPA 4571365 → |
CTM60C5CHS1+ furnace: Z9ES080C16SMPS1AHRI reference: 217019994 | 16.00 | 7.80 | 26800 | 2.30 | EPA 4571368 → |
CTM60C5CHS1+ furnace: Z9ET080C16SMPS1AHRI reference: 217019907 | 16.00 | 7.80 | 26800 | 2.30 | EPA 4571369 → |
CTF60C5CHS1+ furnace: Z9ET080C16SMPS1AHRI reference: 217019906 | 16.00 | 7.80 | 26800 | 2.30 | EPA 4571370 → |
JHE60C5CH2SS2AHRI reference: 218457265 | 16.00 | 8.10 | 27200 | 2.34 | EPA 4639421 → |
JHE48C5CG2SS2AHRI reference: 218457259 | 16.00 | 8.00 | 27200 | 2.10 | EPA 4639427 → |
JHE60D5CH2SS2AHRI reference: 218457253 | 16.00 | 8.10 | 27000 | 2.38 | EPA 4639433 → |
JHE48D5CG2SS2AHRI reference: 218457247 | 16.00 | 8.10 | 27200 | 2.28 | EPA 4639439 → |
CTM60D5CHS2+ furnace: TP9C120D20MP13AHRI reference: 218530229 | 16.00 | 8.00 | 25000 | 2.00 | EPA 4648619 → |
CTM60D5CHS2+ furnace: TM9V120D20MP12AHRI reference: 218530225 | 16.00 | 8.00 | 25000 | 2.00 | EPA 4648623 → |
CTM60D5CHS2+ furnace: Z9ES120D20SMPS1AHRI reference: 218530213 | 16.00 | 8.10 | 27600 | 2.30 | EPA 4648635 → |
CTM60D5CHS2+JMC20D2SN1AHRI reference: 218530209 | 16.00 | 8.10 | 27000 | 2.38 | EPA 4648639 → |
CTM60D5CHS2+JMVT20DC2N1AHRI reference: 218530205 | 16.00 | 8.10 | 27000 | 2.38 | EPA 4648643 → |
CTM60D5CHS2+ furnace: Z8ES130D20LMPS1AHRI reference: 218530199 | 16.00 | 8.10 | 27000 | 2.36 | EPA 4648649 → |
CTM60D5CHS2+ furnace: Z8ES130D20SMPS1AHRI reference: 218530195 | 16.00 | 8.10 | 27000 | 2.36 | EPA 4648653 → |
CTM60D5CHS2+ furnace: Z9ET120D20SMPS1AHRI reference: 218530191 | 16.00 | 8.10 | 27400 | 2.32 | EPA 4648657 → |
CTM60D5CGS2+JMC20D2SN1AHRI reference: 218530181 | 16.00 | 8.10 | 27200 | 2.28 | EPA 4648661 → |
CTM60D5CGS2+JMVT20DC2N1AHRI reference: 218530177 | 16.00 | 8.10 | 27200 | 2.28 | EPA 4648665 → |
CTM60D5CGS2+ furnace: Z8ES130D20LMPS1AHRI reference: 218530171 | 16.00 | 8.10 | 27400 | 2.28 | EPA 4648671 → |
CTM60D5CGS2+ furnace: Z8ES130D20SMPS1AHRI reference: 218530167 | 16.00 | 8.10 | 27400 | 2.28 | EPA 4648675 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →