Fraser-Johnston / AIR-SOURCE HEAT PUMP

XH630E2S11

LX SERIES · source records, page 3

219 published source records · source checked Sep 21, 2026

SEER2 range15.2–17BTU/Wh
HSPF2 range8–8.1BTU/Wh
Cooling capacity28,400–31,000BTU/h

Each efficiency range summarizes published EPA records for XH630E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 219 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–17219 / 219
EER2 · BTU/Wh11–13219 / 219
HSPF2 · BTU/Wh8–8.1219 / 219
Cooling capacity · BTU/h28,400–31,000219 / 219
Heating capacity at 47°F / 8.3°C · BTU/h28,800–30,000219 / 219
Heating capacity at 17°F / −8.3°C · BTU/h18,800–20,200219 / 219
Heating capacity at 5°F / −15°C · BTU/h15,000–16,400219 / 219
COP at 5°F / −15°C2–2.4219 / 219
Equipment / loop typeHP - Split System219 / 219
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)219 / 219
Compressor stagingTwo-stage219 / 219
Connected capabilityNo219 / 219

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTU36B5XDS1+TXV+ furnace: Z8ES100B12LMPS1AHRI reference: 21841829716.008.10152002.36EPA 4608567
CTU36B5XDS1+TXV+ furnace: Z8ES100B12SMPS1AHRI reference: 21841829316.008.10152002.36EPA 4608571
CTF36B5ADS1+ furnace: Z8ES100B12LMPS1AHRI reference: 21841828716.008.10152002.36EPA 4608577
CTF36B5ADS1+ furnace: Z8ES100B12SMPS1AHRI reference: 21841828316.008.10152002.36EPA 4608581
CTM36C5ADS1+ furnace: TP9C080C16MP13AHRI reference: 21841827716.008.10156002.30EPA 4608587
CTM36C5ADS1+ furnace: TM9V080C16MP12AHRI reference: 21841827316.008.10156002.30EPA 4608591
CTM36B5ADS1+ furnace: TP9C080B12MP13AHRI reference: 21841826716.008.00156002.28EPA 4608597
CTM36B5ADS1+ furnace: TM9V080B12MP12AHRI reference: 21841826316.008.00156002.28EPA 4608601
CTU36B5XDS1+TXV+ furnace: TM9E080B12MP12AHRI reference: 21841825716.008.10156002.28EPA 4608607
CTF36B5ADS1+ furnace: TM9E080B12MP12AHRI reference: 21841825116.008.10156002.28EPA 4608613
CTF36C5ADS1+ furnace: Z8VT080C16SMPC1AHRI reference: 21841824716.008.10150002.40EPA 4608617
CTU36B5XDS1+TXV+ furnace: Z9ES080B12SMPS1AHRI reference: 21841822116.008.10158002.26EPA 4608643
CTF36B5ADS1+ furnace: Z9ES080B12SMPS1AHRI reference: 21841821516.008.10158002.26EPA 4608649
CTM36C5ADS1+ furnace: Z8VT080C16SMPC1AHRI reference: 21841820316.008.10150002.40EPA 4608661
CTM36C5ADS1+ furnace: Z9ES080C16SMPS1AHRI reference: 21841819716.008.10154002.32EPA 4608667
CTM36C5ADS1+ furnace: Z9ET080C16SMPS1AHRI reference: 21841819316.008.10154002.32EPA 4608671
CTU36B5XDS1+TXV+ furnace: TP9C080B12MP13AHRI reference: 21841818716.008.10156002.28EPA 4608677
CTU36B5XDS1+TXV+ furnace: TM9V080B12MP12AHRI reference: 21841818316.008.10156002.28EPA 4608681
CTF36B5ADS1+ furnace: TP9C080B12MP13AHRI reference: 21841817716.008.10156002.28EPA 4608687
CTF36B5ADS1+ furnace: TM9V080B12MP12AHRI reference: 21841817316.008.10156002.28EPA 4608691

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →