XH624E2S11
LX SERIES · source records, page 5
147 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for XH624E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 147 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 147 / 147 |
| EER2 · BTU/Wh | 11.7–12 | 147 / 147 |
| HSPF2 · BTU/Wh | 7.8–8.1 | 147 / 147 |
| Cooling capacity · BTU/h | 22,800–24,200 | 147 / 147 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 22,600–24,000 | 147 / 147 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 14,500–15,500 | 147 / 147 |
| Heating capacity at 5°F / −15°C · BTU/h | 11,900–12,800 | 147 / 147 |
| COP at 5°F / −15°C | 2–2.3 | 147 / 147 |
| Equipment / loop type | HP - Split System | 147 / 147 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 147 / 147 |
| Compressor staging | Two-stage | 147 / 147 |
| Connected capability | No | 147 / 147 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTF36B5ADS2+ furnace: Z8VT080B12SMPC1AHRI reference: 218528271 | 16.00 | 8.10 | 12400 | 2.28 | EPA 4647741 → |
CTF30C5ACS2+ furnace: Z9ET100C16SMPS1AHRI reference: 218528261 | 16.00 | 7.80 | 12400 | 2.10 | EPA 4647745 → |
CTF30C5ACS2+ furnace: Z8ET120C20LMPS1AHRI reference: 218528257 | 16.00 | 7.80 | 12300 | 2.14 | EPA 4647749 → |
CTU30B5XCS2+JMC12B2SN1+TXVAHRI reference: 218528213 | 16.00 | 7.80 | 12200 | 2.14 | EPA 4647753 → |
CTF30B5ACS2+JMC12B2SN1AHRI reference: 218528209 | 16.00 | 7.80 | 12200 | 2.14 | EPA 4647757 → |
CTU30B5XCS2+JMVT12BC2N1+TXVAHRI reference: 218528185 | 16.00 | 7.80 | 12200 | 2.14 | EPA 4647761 → |
CTF30B5ACS2+JMVT12BC2N1AHRI reference: 218528181 | 16.00 | 7.80 | 12200 | 2.14 | EPA 4647765 → |
CTF30C5ACS2+JME12C2SN2AHRI reference: 218638219 | 16.00 | 7.80 | 12300 | 2.14 | EPA 4664420 → |
CTU36B5XDS2+JME12B2SN2+TXVAHRI reference: 218638183 | 16.00 | 8.00 | 12000 | 2.26 | EPA 4664438 → |
CTF36B5ADS2+JME12B2SN2AHRI reference: 218638177 | 16.00 | 8.00 | 12000 | 2.26 | EPA 4664444 → |
CTF30C5ACS2+JME16C2SN2AHRI reference: 218638171 | 16.00 | 7.80 | 12300 | 2.16 | EPA 4664450 → |
CTF30A5ADS1+ furnace: Z8VT060A12SMPC1AHRI reference: 217445261 | 15.20 | 8.10 | 12500 | 2.26 | EPA 4045319 → |
CTM36B5ADS1+ furnace: Z8VT080B12SMPC1AHRI reference: 217445264 | 15.20 | 8.10 | 12400 | 2.28 | EPA 4045323 → |
CTF36C5ADS1+ furnace: TP9C100C16MP13AHRI reference: 217993632 | 15.20 | 8.00 | 12000 | 2.00 | EPA 4571077 → |
CTM36C5ADS1+ furnace: TP9C100C16MP13AHRI reference: 217993630 | 15.20 | 8.00 | 12000 | 2.00 | EPA 4571079 → |
CTM36B5ADS1+ furnace: TP9C080B12MP13AHRI reference: 217993628 | 15.20 | 8.00 | 12000 | 2.00 | EPA 4571081 → |
CTU36B5XDS1+TXV+ furnace: TP9C080B12MP13AHRI reference: 217993626 | 15.20 | 8.00 | 12000 | 2.00 | EPA 4571083 → |
CTF36B5ADS1+ furnace: TP9C080B12MP13AHRI reference: 217993624 | 15.20 | 8.00 | 12000 | 2.00 | EPA 4571085 → |
CTF36C5ADS1+ furnace: TM9V100C16MP12AHRI reference: 217993615 | 15.20 | 8.00 | 12000 | 2.00 | EPA 4571088 → |
CTM36C5ADS1+ furnace: TM9V100C16MP12AHRI reference: 217993613 | 15.20 | 8.00 | 12000 | 2.00 | EPA 4571090 → |