272 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8BTU/Wh
Cooling capacity17,000–18,300BTU/h

Each efficiency range summarizes published EPA records for XH618E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 272 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16272 / 272
EER2 · BTU/Wh12–12.5272 / 272
HSPF2 · BTU/Wh7.8–8272 / 272
Cooling capacity · BTU/h17,000–18,300272 / 272
Heating capacity at 47°F / 8.3°C · BTU/h16,100–17,000272 / 272
Heating capacity at 17°F / −8.3°C · BTU/h10,700–11,300272 / 272
Heating capacity at 5°F / −15°C · BTU/h8,700–9,100272 / 272
COP at 5°F / −15°C2.26–2.34272 / 272
Equipment / loop typeHP - Split System272 / 272
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)272 / 272
Compressor stagingSingle stage272 / 272
Connected capabilityNo272 / 272

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTM24A5ABS1+ furnace: TMLE040A12MP11AHRI reference: 21841770915.207.8090002.26EPA 4609085 →
CTM24A5ABS1+ furnace: TM8E040A12MP11AHRI reference: 21841770515.207.8090002.26EPA 4609089 →
CTU24A5XBS1+TXV+ furnace: Z8ES040A12LMPS1AHRI reference: 21841768515.207.8088002.28EPA 4609093 →
CTU24A5XBS1+TXV+ furnace: Z8ES040A12SMPS1AHRI reference: 21841768115.207.8088002.28EPA 4609097 →
CTF24A5ABS1+ furnace: Z8ES040A12LMPS1AHRI reference: 21841767715.207.8088002.28EPA 4609101 →
CTF24A5ABS1+ furnace: Z8ES040A12SMPS1AHRI reference: 21841767315.207.8088002.28EPA 4609105 →
CTM24A5ABS1+ furnace: Z8ET060A12LMPS1AHRI reference: 21841766515.207.8088002.26EPA 4609109 →
CTU24A5XBS1+TXV+ furnace: TMLE060A12MP11AHRI reference: 21841766115.207.8090002.26EPA 4609113 →
CTU24A5XBS1+TXV+ furnace: TM8E060A12MP11AHRI reference: 21841765715.207.8090002.26EPA 4609117 →
CTF24A5ABS1+ furnace: TMLE060A12MP11AHRI reference: 21841765315.207.8090002.26EPA 4609121 →
CTF24A5ABS1+ furnace: TM8E060A12MP11AHRI reference: 21841764915.207.8090002.26EPA 4609125 →
CTM24A5ABS1+ furnace: Z8ES060A12LMPS1AHRI reference: 21841760115.207.8090002.28EPA 4609129 →
CTM24A5ABS1+ furnace: Z8ES060A12SMPS1AHRI reference: 21841759715.207.8090002.28EPA 4609133 →
CTU24A5XBS1+TXV+ furnace: Z8ES060A12LMPS1AHRI reference: 21841757715.207.8088002.28EPA 4609137 →
CTU24A5XBS1+TXV+ furnace: Z8ES060A12SMPS1AHRI reference: 21841757315.207.8088002.28EPA 4609141 →
CTF24A5ABS1+ furnace: Z8ES060A12LMPS1AHRI reference: 21841756915.207.8088002.28EPA 4609145 →
CTF24A5ABS1+ furnace: Z8ES060A12SMPS1AHRI reference: 21841756515.207.8088002.28EPA 4609149 →
CTU30B5XCS1+TXV+ furnace: Z8ES100B12LMPS1AHRI reference: 21841754515.207.8088002.30EPA 4609153 →
CTU30B5XCS1+TXV+ furnace: Z8ES100B12SMPS1AHRI reference: 21841754115.207.8088002.30EPA 4609157 →
CTF30B5ACS1+ furnace: Z8ES100B12LMPS1AHRI reference: 21841753715.207.8088002.30EPA 4609161 →