XH618E2S11
LX SERIES · source records, page 2
272 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for XH618E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 272 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 272 / 272 |
| EER2 · BTU/Wh | 12–12.5 | 272 / 272 |
| HSPF2 · BTU/Wh | 7.8–8 | 272 / 272 |
| Cooling capacity · BTU/h | 17,000–18,300 | 272 / 272 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 16,100–17,000 | 272 / 272 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 10,700–11,300 | 272 / 272 |
| Heating capacity at 5°F / −15°C · BTU/h | 8,700–9,100 | 272 / 272 |
| COP at 5°F / −15°C | 2.26–2.34 | 272 / 272 |
| Equipment / loop type | HP - Split System | 272 / 272 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 272 / 272 |
| Compressor staging | Single stage | 272 / 272 |
| Connected capability | No | 272 / 272 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTM30B5ACS1+JME08B2SN1AHRI reference: 218417823 | 16.00 | 8.00 | 8900 | 2.34 | EPA 4609001 → |
CTU30B5XCS1+JME12B2SN1+TXVAHRI reference: 218417811 | 16.00 | 8.00 | 8900 | 2.34 | EPA 4609013 → |
CTF30B5ACS1+JME12B2SN1AHRI reference: 218417807 | 16.00 | 8.00 | 8900 | 2.34 | EPA 4609017 → |
CTU30B5XCS1+JMET12BS2N1+TXVAHRI reference: 218417803 | 16.00 | 8.00 | 8900 | 2.32 | EPA 4609021 → |
CTF30B5ACS1+JMET12BS2N1AHRI reference: 218417799 | 16.00 | 8.00 | 8900 | 2.32 | EPA 4609025 → |
CTM30B5ACS1+JMET08BS2N1AHRI reference: 218417795 | 16.00 | 8.00 | 8900 | 2.32 | EPA 4609029 → |
JHC18B5AB2SS1AHRI reference: 218417431 | 16.00 | 8.00 | 8900 | 2.32 | EPA 4609221 → |
JHC24B5AC2SS1AHRI reference: 218417391 | 16.00 | 8.00 | 8900 | 2.32 | EPA 4609253 → |
JHE18B5AB2SS1AHRI reference: 218417175 | 16.00 | 8.00 | 8800 | 2.30 | EPA 4609403 → |
CTU30B5XCS2+TXV+ furnace: Z8VT080B12SMPC1AHRI reference: 218530887 | 16.00 | 8.00 | 8900 | 2.34 | EPA 4648093 → |
CTF30B5ACS2+ furnace: Z8VT080B12SMPC1AHRI reference: 218530883 | 16.00 | 8.00 | 8900 | 2.34 | EPA 4648097 → |
CTU30B5XCS2+JMC12B2SN1+TXVAHRI reference: 218530879 | 16.00 | 8.00 | 8900 | 2.34 | EPA 4648101 → |
CTF30B5ACS2+JMC12B2SN1AHRI reference: 218530875 | 16.00 | 8.00 | 8900 | 2.34 | EPA 4648105 → |
CTF24B5ABS2+ furnace: Z8VT080B12SMPC1AHRI reference: 218530757 | 16.00 | 8.00 | 8900 | 2.34 | EPA 4648175 → |
CTM30B5ACS2+JMC12B2SN1AHRI reference: 218531215 | 16.00 | 8.00 | 9000 | 2.32 | EPA 4649737 → |
CTM30B5ACS2+ furnace: Z8VT080B12SMPC1AHRI reference: 218531211 | 16.00 | 8.00 | 8900 | 2.34 | EPA 4649741 → |
CTM24B5ABS2+ furnace: Z8VT080B12SMPC1AHRI reference: 218531207 | 16.00 | 8.00 | 8900 | 2.32 | EPA 4649745 → |
CTF24B5ABS2+JME12B2SN2AHRI reference: 218638441 | 16.00 | 8.00 | 8800 | 2.30 | EPA 4664234 → |
CTF24B5ABS2+JME08B2SN2AHRI reference: 218638437 | 16.00 | 8.00 | 8900 | 2.32 | EPA 4664238 → |
CTM30B5ACS2+JME08B2SN2AHRI reference: 218638433 | 16.00 | 8.00 | 8900 | 2.32 | EPA 4664242 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →