Fraser-Johnston / AIR-SOURCE HEAT PUMP

XH548E2S11

LX SERIES · source records, page 5

355 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity44,500–48,000BTU/h

Each efficiency range summarizes published EPA records for XH548E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 355 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16355 / 355
EER2 · BTU/Wh11–12355 / 355
HSPF2 · BTU/Wh7.8–8.1355 / 355
Cooling capacity · BTU/h44,500–48,000355 / 355
Heating capacity at 47°F / 8.3°C · BTU/h45,000–48,000355 / 355
Heating capacity at 17°F / −8.3°C · BTU/h29,200–32,200355 / 355
Heating capacity at 5°F / −15°C · BTU/h24,600–27,000355 / 355
COP at 5°F / −15°C2.1–2.42355 / 355
Equipment / loop typeHP - Split System355 / 355
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)355 / 355
Compressor stagingTwo-stage355 / 355
Connected capabilityNo355 / 355

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTF60C5CHS1+JMVT17CC2N1AHRI reference: 21442664815.207.80262002.40EPA 3991909 →
CTF60C5CHS1+JMC16C2SN1AHRI reference: 21442665715.207.80262002.40EPA 3991913 →
CTM60C5CHS1+ furnace: TL8E100C20UH11AHRI reference: 21442666615.207.80258002.38EPA 3991919 →
CTF60C5CHS1+JMET16CS2N1AHRI reference: 21442830115.208.10262002.38EPA 3991935 →
CTF60D5CGS1+JMET18DS2N1AHRI reference: 21442837315.207.80250002.26EPA 3991939 →
CTF60D5CHS1+JME18D2SN1AHRI reference: 21442862215.208.10260002.42EPA 3991947 →
CTM60C5CHS1+ furnace: TL9E100C20UH11AHRI reference: 21442862715.207.80258002.36EPA 3991950 →
CTF60D5CHS1+JMVT20DC2N1AHRI reference: 21442714115.208.10262002.42EPA 3992003 →
CTM60C5CHS1+ furnace: TM9V100C16MP12AHRI reference: 21442736015.207.80260002.36EPA 3992008 →
CTM60C5CHS1+ furnace: TP9C100C16MP13AHRI reference: 21442736515.207.80260002.36EPA 3992016 →
CTF60D5CHS1+JMET18DS2N1AHRI reference: 21442740615.208.10260002.40EPA 3992022 →
CTF60C5CGS1+JME16C2SN1AHRI reference: 21442743615.207.80250002.26EPA 3992026 →
CTM60C5CHS1+ furnace: TM8V120C20MP12AHRI reference: 21442747515.207.80258002.36EPA 3992032 →
CTM60C5CHS1+ furnace: TM8V100C20MP12AHRI reference: 21442748015.207.80258002.36EPA 3992038 →
CTM60C5CHS1+ furnace: TPLC100C20MP13AHRI reference: 21442749015.207.80258002.36EPA 3992048 →
CTF60C5CHS1+JME16C2SN1AHRI reference: 21442757715.208.10260002.40EPA 3992059 →
CTF60C5CHS1+JME12C2SN1AHRI reference: 21443193315.207.80258002.40EPA 3992080 →
CTF60C5CHS1+JMVT16CC2N1AHRI reference: 21443196415.207.80262002.40EPA 3992082 →
CTF60C5CHS1+JMET12CS2N1AHRI reference: 21443203215.207.80258002.40EPA 3992089 →
CTU60D5XHS1+TXV+ furnace: Z9ET120D20SMPS1AHRI reference: 21637688515.207.80260002.38EPA 3992217 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →