Fraser-Johnston / AIR-SOURCE HEAT PUMP

XH548E2S11

LX SERIES · source records, page 18

355 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity44,500–48,000BTU/h

Each efficiency range summarizes published EPA records for XH548E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 355 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16355 / 355
EER2 · BTU/Wh11–12355 / 355
HSPF2 · BTU/Wh7.8–8.1355 / 355
Cooling capacity · BTU/h44,500–48,000355 / 355
Heating capacity at 47°F / 8.3°C · BTU/h45,000–48,000355 / 355
Heating capacity at 17°F / −8.3°C · BTU/h29,200–32,200355 / 355
Heating capacity at 5°F / −15°C · BTU/h24,600–27,000355 / 355
COP at 5°F / −15°C2.1–2.42355 / 355
Equipment / loop typeHP - Split System355 / 355
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)355 / 355
Compressor stagingTwo-stage355 / 355
Connected capabilityNo355 / 355

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTU60C5XGS2+JMVT17CC2N1+TXVAHRI reference: 21851698615.207.80250002.26EPA 4642155 →
CTF60C5CGS2+JMVT17CC2N1AHRI reference: 21851698215.207.80250002.26EPA 4642159 →
CTU60C5XGS2+TXV+ furnace: Z8ET120C20LMPS1AHRI reference: 21851696215.207.80260002.26EPA 4642163 →
CTF60C5CGS2+ furnace: Z8ET120C20LMPS1AHRI reference: 21851695815.207.80260002.26EPA 4642167 →
CTM60D5CGS2+JME18D2SN2AHRI reference: 21863696515.207.80254002.28EPA 4663808 →
CTF60D5CGS2+JME18D2SN2AHRI reference: 21863695715.207.80250002.26EPA 4663816 →
CTM60C5CHS2+JME12C2SN2AHRI reference: 21863695315.208.00258002.40EPA 4663820 →
CTF60C5CHS2+JME16C2SN2AHRI reference: 21863694915.208.10262002.38EPA 4663824 →
CTM60C5CGS2+JME16C2SN2AHRI reference: 21863693315.207.80256002.28EPA 4663828 →
CTU60C5XGS2+JME16C2SN2+TXVAHRI reference: 21863692915.207.80252002.24EPA 4663832 →
CTF60C5CGS2+JME16C2SN2AHRI reference: 21863692515.207.80252002.24EPA 4663836 →
CTM60C5CHS2+JME16C2SN2AHRI reference: 21863692115.208.10264002.40EPA 4663840 →
CTF60D5CHS2+JME18D2SN2AHRI reference: 21863691315.208.10260002.40EPA 4663848 →
CTM60D5CHS2+JME18D2SN2AHRI reference: 21863690915.208.10262002.42EPA 4663852 →
CTF60C5CHS2+JME12C2SN2AHRI reference: 21863690515.207.80258002.40EPA 4663856 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →