XH536E2S11
LX SERIES · source records, page 8
273 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for XH536E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 273 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 273 / 273 |
| EER2 · BTU/Wh | 10–12 | 273 / 273 |
| HSPF2 · BTU/Wh | 7.8–8.1 | 273 / 273 |
| Cooling capacity · BTU/h | 32,400–35,000 | 273 / 273 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 30,600–32,800 | 273 / 273 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 20,400–22,000 | 273 / 273 |
| Heating capacity at 5°F / −15°C · BTU/h | 17,000–18,400 | 273 / 273 |
| COP at 5°F / −15°C | 2–2.44 | 273 / 273 |
| Equipment / loop type | HP - Split System | 273 / 273 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 273 / 273 |
| Compressor staging | Two-stage | 273 / 273 |
| Connected capability | No | 273 / 273 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTM48C5CFS1+ furnace: Z9ET080C16SMPS1AHRI reference: 216437808 | 15.20 | 8.10 | 18300 | 2.32 | EPA 4047114 → |
CTF48C5CFS1+ furnace: Z8ES080C20LMPS1AHRI reference: 216785597 | 15.20 | 8.10 | 17600 | 2.00 | EPA 4047121 → |
CTU48C5XFS1+TXV+ furnace: Z8ES080C20LMPS1AHRI reference: 216785612 | 15.20 | 8.10 | 17600 | 2.00 | EPA 4047126 → |
CTF48C5CFS1+ furnace: Z8ES100C16LMPS1AHRI reference: 216785627 | 15.20 | 8.10 | 17500 | 2.00 | EPA 4047129 → |
CTU48C5XFS1+TXV+ furnace: Z8ES100C16LMPS1AHRI reference: 216785642 | 15.20 | 8.10 | 17500 | 2.00 | EPA 4047136 → |
JHE36B5CD2SS1AHRI reference: 214431696 | 15.20 | 8.10 | 17600 | 2.00 | EPA 4498115 → |
CTM48C5CFS1+ furnace: TMLV100C16MP12AHRI reference: 214431315 | 15.20 | 8.10 | 18300 | 2.00 | EPA 4529528 → |
CTF48C5CFS1+ furnace: TMLV100C16MP12AHRI reference: 214431286 | 15.20 | 8.10 | 18300 | 2.00 | EPA 4529533 → |
CTU48C5XFS1+TXV+ furnace: TMLV100C16MP12AHRI reference: 214808607 | 15.20 | 8.10 | 18300 | 2.00 | EPA 4529540 → |
CTU48C5XFS1+TXV+ furnace: TL9E080C16UH11AHRI reference: 214808540 | 15.20 | 7.80 | 17600 | 2.00 | EPA 4572276 → |
CTM48C5CFS1+ furnace: TL9E080C16UH11AHRI reference: 214431139 | 15.20 | 7.80 | 17600 | 2.00 | EPA 4572413 → |
CTF48C5CFS1+ furnace: TL9E080C16UH11AHRI reference: 214431134 | 15.20 | 7.80 | 17600 | 2.00 | EPA 4572418 → |
JHE36C5CD2SS2AHRI reference: 218457041 | 15.20 | 7.80 | 17000 | 2.30 | EPA 4639505 → |
JHE42C5CF2SS2AHRI reference: 218457037 | 15.20 | 8.10 | 17300 | 2.00 | EPA 4639509 → |
JHE36B5CD2SS2AHRI reference: 218457033 | 15.20 | 8.10 | 17600 | 2.00 | EPA 4639513 → |
CTU36B5XDS2+JMC12B2SN1+TXVAHRI reference: 218518604 | 15.20 | 8.10 | 17700 | 2.00 | EPA 4641537 → |
CTF36B5CDS2+JMC12B2SN1AHRI reference: 218518600 | 15.20 | 8.10 | 17700 | 2.00 | EPA 4641541 → |
CTU36B5XDS2+JMVT12BC2N1+TXVAHRI reference: 218518580 | 15.20 | 7.80 | 17100 | 2.00 | EPA 4641545 → |
CTF36B5CDS2+JMVT12BC2N1AHRI reference: 218518576 | 15.20 | 7.80 | 17100 | 2.00 | EPA 4641549 → |
CTM48D5CFS2+JMC20D2SN1AHRI reference: 218519368 | 15.20 | 8.10 | 17700 | 2.44 | EPA 4642762 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →