Fraser-Johnston / AIR-SOURCE HEAT PUMP

XH536E2S11

LX SERIES · source records, page 3

273 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity32,400–35,000BTU/h

Each efficiency range summarizes published EPA records for XH536E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 273 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16273 / 273
EER2 · BTU/Wh10–12273 / 273
HSPF2 · BTU/Wh7.8–8.1273 / 273
Cooling capacity · BTU/h32,400–35,000273 / 273
Heating capacity at 47°F / 8.3°C · BTU/h30,600–32,800273 / 273
Heating capacity at 17°F / −8.3°C · BTU/h20,400–22,000273 / 273
Heating capacity at 5°F / −15°C · BTU/h17,000–18,400273 / 273
COP at 5°F / −15°C2–2.44273 / 273
Equipment / loop typeHP - Split System273 / 273
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)273 / 273
Compressor stagingTwo-stage273 / 273
Connected capabilityNo273 / 273

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTF36B5CDS1+JMVT12BC2N1AHRI reference: 21442932615.207.80171002.00EPA 3559110 →
CTF48C5CFS1+ furnace: Z8ES120C16SMPS1AHRI reference: 21460548615.208.10174002.00EPA 3559151 →
CTM36C5CDS1+ furnace: Z8ES080C16SMPS1AHRI reference: 21460557615.208.10174002.42EPA 3559156 →
CTM48C5CFS1+ furnace: Z8ES120C16SMPS1AHRI reference: 21460567615.208.10177002.40EPA 3559161 →
CTF36B5CDS1+JMC12B2SN1AHRI reference: 21443156515.208.10177002.00EPA 3559165 →
CTF36C5CDS1+JMC16C2SN1AHRI reference: 21443159015.208.10173002.00EPA 3559170 →
CTM36C5CDS1+JME12C2SN1AHRI reference: 21443162215.208.10176002.42EPA 3559175 →
CTF36C5CDS1+JMC17C2SN1AHRI reference: 21443169115.208.10171002.00EPA 3559180 →
CTF36B5CDS1+JME12B2SN1AHRI reference: 21443171615.208.10174002.00EPA 3559185 →
CTF36C5CDS1+JME16C2SN1AHRI reference: 21443175015.208.10173002.00EPA 3559190 →
CTF36C5CDS1+JME12C2SN1AHRI reference: 21443179015.208.10172002.00EPA 3559195 →
CTF48C5CFS1+ furnace: Z9ES080C16SMPS1AHRI reference: 21460513615.207.80172002.00EPA 3559199 →
CTM48C5CFS1+ furnace: Z8ES100C16SMPS1AHRI reference: 21460529615.208.10178002.40EPA 3559204 →
CTF36C5CDS1+ furnace: Z8ES080C16SMPS1AHRI reference: 21460537115.208.10171002.00EPA 3559209 →
CTF48C5CFS1+ furnace: Z8ES100C16SMPS1AHRI reference: 21460575115.208.10175002.00EPA 3559216 →
CTU36B5XDS1+JMVT12BC2N1+TXVAHRI reference: 21480822715.207.80171002.00EPA 3559962 →
CTU36B5XDS1+JMC12B2SN1+TXVAHRI reference: 21480823215.208.10177002.00EPA 3559968 →
CTU36B5XDS1+JME12B2SN1+TXVAHRI reference: 21480823715.208.10174002.00EPA 3559973 →
CTU48C5XFS1+JMET16CS2N1+TXVAHRI reference: 21480854515.208.10173002.00EPA 3559976 →
CTU48C5XFS1+JMC16C2SN1+TXVAHRI reference: 21480855015.208.10172002.00EPA 3559982 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →