Each efficiency range summarizes published EPA records for XH536E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 273 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 273 / 273 |
| EER2 · BTU/Wh | 10–12 | 273 / 273 |
| HSPF2 · BTU/Wh | 7.8–8.1 | 273 / 273 |
| Cooling capacity · BTU/h | 32,400–35,000 | 273 / 273 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 30,600–32,800 | 273 / 273 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 20,400–22,000 | 273 / 273 |
| Heating capacity at 5°F / −15°C · BTU/h | 17,000–18,400 | 273 / 273 |
| COP at 5°F / −15°C | 2–2.44 | 273 / 273 |
| Equipment / loop type | HP - Split System | 273 / 273 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 273 / 273 |
| Compressor staging | Two-stage | 273 / 273 |
| Connected capability | No | 273 / 273 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTF36B5CDS1+JMVT12BC2N1AHRI reference: 214429326 | 15.20 | 7.80 | 17100 | 2.00 | EPA 3559110 → |
CTF48C5CFS1+ furnace: Z8ES120C16SMPS1AHRI reference: 214605486 | 15.20 | 8.10 | 17400 | 2.00 | EPA 3559151 → |
CTM36C5CDS1+ furnace: Z8ES080C16SMPS1AHRI reference: 214605576 | 15.20 | 8.10 | 17400 | 2.42 | EPA 3559156 → |
CTM48C5CFS1+ furnace: Z8ES120C16SMPS1AHRI reference: 214605676 | 15.20 | 8.10 | 17700 | 2.40 | EPA 3559161 → |
CTF36B5CDS1+JMC12B2SN1AHRI reference: 214431565 | 15.20 | 8.10 | 17700 | 2.00 | EPA 3559165 → |
CTF36C5CDS1+JMC16C2SN1AHRI reference: 214431590 | 15.20 | 8.10 | 17300 | 2.00 | EPA 3559170 → |
CTM36C5CDS1+JME12C2SN1AHRI reference: 214431622 | 15.20 | 8.10 | 17600 | 2.42 | EPA 3559175 → |
CTF36C5CDS1+JMC17C2SN1AHRI reference: 214431691 | 15.20 | 8.10 | 17100 | 2.00 | EPA 3559180 → |
CTF36B5CDS1+JME12B2SN1AHRI reference: 214431716 | 15.20 | 8.10 | 17400 | 2.00 | EPA 3559185 → |
CTF36C5CDS1+JME16C2SN1AHRI reference: 214431750 | 15.20 | 8.10 | 17300 | 2.00 | EPA 3559190 → |
CTF36C5CDS1+JME12C2SN1AHRI reference: 214431790 | 15.20 | 8.10 | 17200 | 2.00 | EPA 3559195 → |
CTF48C5CFS1+ furnace: Z9ES080C16SMPS1AHRI reference: 214605136 | 15.20 | 7.80 | 17200 | 2.00 | EPA 3559199 → |
CTM48C5CFS1+ furnace: Z8ES100C16SMPS1AHRI reference: 214605296 | 15.20 | 8.10 | 17800 | 2.40 | EPA 3559204 → |
CTF36C5CDS1+ furnace: Z8ES080C16SMPS1AHRI reference: 214605371 | 15.20 | 8.10 | 17100 | 2.00 | EPA 3559209 → |
CTF48C5CFS1+ furnace: Z8ES100C16SMPS1AHRI reference: 214605751 | 15.20 | 8.10 | 17500 | 2.00 | EPA 3559216 → |
CTU36B5XDS1+JMVT12BC2N1+TXVAHRI reference: 214808227 | 15.20 | 7.80 | 17100 | 2.00 | EPA 3559962 → |
CTU36B5XDS1+JMC12B2SN1+TXVAHRI reference: 214808232 | 15.20 | 8.10 | 17700 | 2.00 | EPA 3559968 → |
CTU36B5XDS1+JME12B2SN1+TXVAHRI reference: 214808237 | 15.20 | 8.10 | 17400 | 2.00 | EPA 3559973 → |
CTU48C5XFS1+JMET16CS2N1+TXVAHRI reference: 214808545 | 15.20 | 8.10 | 17300 | 2.00 | EPA 3559976 → |
CTU48C5XFS1+JMC16C2SN1+TXVAHRI reference: 214808550 | 15.20 | 8.10 | 17200 | 2.00 | EPA 3559982 → |