XH518E2S11
LX SERIES · source records, page 2
235 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for XH518E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 235 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 235 / 235 |
| EER2 · BTU/Wh | 12–12.5 | 235 / 235 |
| HSPF2 · BTU/Wh | 7.8 | 235 / 235 |
| Cooling capacity · BTU/h | 17,000–18,600 | 235 / 235 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 16,100–17,000 | 235 / 235 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 10,700–11,300 | 235 / 235 |
| Heating capacity at 5°F / −15°C · BTU/h | 8,700–9,100 | 235 / 235 |
| COP at 5°F / −15°C | 2.26–2.34 | 235 / 235 |
| Equipment / loop type | HP - Split System | 235 / 235 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 235 / 235 |
| Compressor staging | Single stage | 235 / 235 |
| Connected capability | No | 235 / 235 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTF24B5ABS1+JME08B2SN1AHRI reference: 215740349 | 15.20 | 7.80 | 8800 | 2.32 | EPA 3652706 → |
CTU30B5XCS1+JME12B2SN1+TXVAHRI reference: 215740354 | 15.20 | 7.80 | 8900 | 2.34 | EPA 3652711 → |
CTF30B5ACS1+JME08B2SN1AHRI reference: 215740359 | 15.20 | 7.80 | 8900 | 2.34 | EPA 3652716 → |
CTM30B5ACS1+JMET08BS2N1AHRI reference: 215740365 | 15.20 | 7.80 | 8900 | 2.32 | EPA 3652722 → |
CTM24B5ABS1+JMET12BS2N1AHRI reference: 215740370 | 15.20 | 7.80 | 8800 | 2.30 | EPA 3652727 → |
CTM30B5ACS1+JMET12BS2N1AHRI reference: 215740375 | 15.20 | 7.80 | 8800 | 2.30 | EPA 3652733 → |
CTF30B5ACS1+JMET12BS2N1AHRI reference: 215740387 | 15.20 | 7.80 | 8900 | 2.32 | EPA 3652734 → |
CTU30B5XCS1+JME08B2SN1+TXVAHRI reference: 215740380 | 15.20 | 7.80 | 8900 | 2.34 | EPA 3652742 → |
CTM30B5ACS1+JME08B2SN1AHRI reference: 215740392 | 15.20 | 7.80 | 8900 | 2.34 | EPA 3652748 → |
CTM24B5ABS1+JMET08BS2N1AHRI reference: 215740397 | 15.20 | 7.80 | 8900 | 2.30 | EPA 3652754 → |
CTF24B5ABS1+JME12B2SN1AHRI reference: 215740402 | 15.20 | 7.80 | 8800 | 2.32 | EPA 3652759 → |
CTF30B5ACS1+JMC12B2SN1AHRI reference: 215740404 | 15.20 | 7.80 | 8900 | 2.34 | EPA 3652760 → |
CTU30B5XCS1+JMET12BS2N1+TXVAHRI reference: 215740409 | 15.20 | 7.80 | 8900 | 2.32 | EPA 3652764 → |
CTM24B5ABS1+JME08B2SN1AHRI reference: 215740414 | 15.20 | 7.80 | 8800 | 2.30 | EPA 3652771 → |
CTF24B5ABS1+JMET12BS2N1AHRI reference: 215740419 | 15.20 | 7.80 | 8800 | 2.30 | EPA 3652776 → |
CTM24B5ABS1+JMC12B2SN1AHRI reference: 215740424 | 15.20 | 7.80 | 8900 | 2.32 | EPA 3652781 → |
CTF24A5ABS1+ furnace: TMLV060A12MP12AHRI reference: 215820539 | 15.20 | 7.80 | 8900 | 2.26 | EPA 3712598 → |
CTF24A5ABS1+ furnace: TPLC060A12MP13AHRI reference: 215820544 | 15.20 | 7.80 | 8900 | 2.26 | EPA 3712603 → |
CTU24A5XBS1+TXV+ furnace: TM8V060A12MP12AHRI reference: 215820551 | 15.20 | 7.80 | 8900 | 2.26 | EPA 3712610 → |
CTU24A5XBS1+TXV+ furnace: TMLV060A12MP12AHRI reference: 215820556 | 15.20 | 7.80 | 8900 | 2.26 | EPA 3712615 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →