Fraser-Johnston / AIR-SOURCE HEAT PUMP

XD560E2D11

XD5

4 published source records · source checked Sep 21, 2026

SEER2 range16–17BTU/Wh
HSPF2 range8.5BTU/Wh
Cooling capacity34,200–55,000BTU/h

Each efficiency range summarizes published EPA records for XD560E2D11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 4 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh16–174 / 4
EER2 · BTU/Wh10–11.74 / 4
HSPF2 · BTU/Wh8.54 / 4
Cooling capacity · BTU/h34,200–55,0004 / 4
Heating capacity at 47°F / 8.3°C · BTU/h34,200–56,0004 / 4
Heating capacity at 17°F / −8.3°C · BTU/h33,000–40,0004 / 4
Heating capacity at 5°F / −15°C · BTU/h32,200–39,5004 / 4
COP at 5°F / −15°C1.8–1.94 / 4
Equipment / loop typeHP - Split System4 / 4
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)4 / 4
Compressor stagingContinuously variable4 / 4
Connected capabilityNo · Yes4 / 4

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
JDE36E5XX2DS1Cold climate designationAHRI reference: 21845032017.008.50342001.80EPA 4624144
JDE48F5XX2DS1Cold climate designationAHRI reference: 21845031917.008.50336001.87EPA 4624145
JDE60F5XX2DS1Cold climate designationAHRI reference: 21845032916.508.50395001.87EPA 4624135
CDM48C5XXS1+ furnace: Y82E080C16LMPS1Cold climate designationAHRI reference: 21878794116.008.50322001.90EPA 4706521

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →