Fraser-Johnston / AIR-SOURCE HEAT PUMP

THF2B60T21

LX SERIES · source records, page 2

185 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity53,000–57,000BTU/h

Each efficiency range summarizes published EPA records for THF2B60T21. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 185 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16185 / 185
EER2 · BTU/Wh11–12185 / 185
HSPF2 · BTU/Wh7.8–8.1185 / 185
Cooling capacity · BTU/h53,000–57,000185 / 185
Heating capacity at 47°F / 8.3°C · BTU/h54,500–59,500185 / 185
Heating capacity at 17°F / −8.3°C · BTU/h37,400–39,000185 / 185
Heating capacity at 5°F / −15°C · BTU/h29,200–32,800185 / 185
COP at 5°F / −15°C2–2.46185 / 185
Equipment / loop typeHP - Split System185 / 185
Refrigerant / source-reported GWPR-410A (GWP:2088)185 / 185
Compressor stagingTwo-stage185 / 185
Connected capabilityNo185 / 185

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
XAHC60HBCN1+ furnace: Z8ES080C16SMPS1AHRI reference: 21241476515.207.80324002.34EPA 2479077 →
XAFD60JXXN1+TXV+ furnace: Z8ES080C16LMPS1AHRI reference: 21248177215.208.10314002.42EPA 2479553 →
XAHD60JBCN1+ furnace: Z8ES100C20LMPS1AHRI reference: 21248176515.208.10312002.36EPA 2479584 →
XAFD60JBCN1+ furnace: Z8ES130D20SMPS1AHRI reference: 21241515415.208.10314002.40EPA 2480265 →
XAHD60JBCN1+ furnace: Z8ES100C16SMPS1AHRI reference: 21241522415.208.10312002.36EPA 2480268 →
XAHD60HBCN1+ furnace: Z8ES120C16LMPS1AHRI reference: 21247871215.207.80326002.34EPA 2480272 →
XAHD60JXXN1+TXV+ furnace: Z8ES100C16SMPS1AHRI reference: 21241521915.208.10312002.36EPA 2480672 →
XAFC60HBCN1+ furnace: Z8ES080C16SMPS1AHRI reference: 21241479015.207.80310002.34EPA 2481554 →
XAHD60JBCN1+ furnace: Z8ES130D20SMPS1AHRI reference: 21241502415.208.10310002.38EPA 2481795 →
XAHD60JXXN1+TXV+ furnace: Z8ES130D20SMPS1AHRI reference: 21241501915.208.10310002.38EPA 2481798 →
XAFD60JXXN1+TXV+ furnace: Z8ES130D20SMPS1AHRI reference: 21241502915.208.10314002.40EPA 2481805 →
XAFD60HBCN1+ furnace: Z8ES080C16SMPS1AHRI reference: 21241477515.207.80310002.34EPA 2481958 →
XAFC60HBCN1+ furnace: Z8ES080C16LMPS1AHRI reference: 21248000415.207.80310002.34EPA 2482183 →
XAFD60JXXN1+TXV+ furnace: Z8ES120C16LMPS1AHRI reference: 21248001815.208.10314002.40EPA 2482191 →
XAFD60JBCN1+ furnace: Z8ES130D20LMPS1AHRI reference: 21248496615.208.10314002.40EPA 2482328 →
XAFD60HBCN1+ furnace: Z8ES080C16LMPS1AHRI reference: 21248929815.207.80310002.34EPA 2482417 →
XAHD60JXXN1+TXV+ furnace: Z8ES120C16LMPS1AHRI reference: 21248931215.208.10310002.38EPA 2482431 →
XAHD60JBCN1+ furnace: Z8ES120C16LMPS1AHRI reference: 21248931915.208.10310002.38EPA 2482442 →
XAHD60JBCN1+ furnace: Z8ES080C20LMPS1AHRI reference: 21248933315.208.10312002.36EPA 2482455 →
XAHD60JXXN1+TXV+ furnace: Z8ES080C20LMPS1AHRI reference: 21248932615.208.10312002.36EPA 2482459 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.