Fraser-Johnston / AIR-SOURCE HEAT PUMP

THF2B48T21

LX SERIES · source records, page 7

348 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity44,500–47,500BTU/h

Each efficiency range summarizes published EPA records for THF2B48T21. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 348 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16348 / 348
EER2 · BTU/Wh11–12348 / 348
HSPF2 · BTU/Wh7.8–8.1348 / 348
Cooling capacity · BTU/h44,500–47,500348 / 348
Heating capacity at 47°F / 8.3°C · BTU/h43,500–47,500348 / 348
Heating capacity at 17°F / −8.3°C · BTU/h29,200–34,200348 / 348
Heating capacity at 5°F / −15°C · BTU/h23,400–29,800348 / 348
COP at 5°F / −15°C2.22–2.84348 / 348
Equipment / loop typeHP - Split System348 / 348
Refrigerant / source-reported GWPR-410A (GWP:2088)348 / 348
Compressor stagingTwo-stage348 / 348
Connected capabilityNo348 / 348

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
XAHC60GBCN1+ furnace: Z8ET080B12LMPS1AHRI reference: 21241713715.207.80248002.34EPA 2476512 →
XAFC60HBCN1+ furnace: Z8ES080C20LMPS1AHRI reference: 21247866415.207.80252002.32EPA 2477008 →
XAHC60GBCN1+ furnace: Z8ES080B12SMPS1AHRI reference: 21241751215.207.80248002.34EPA 2477347 →
XAFD60HBCN1+ furnace: Z8ES120C16SMPS1AHRI reference: 21241378615.207.80250002.34EPA 2477576 →
XAHC60GBCN1+ furnace: Z8ES080B12LMPS1AHRI reference: 21248589115.207.80248002.34EPA 2477842 →
XAHD60HBCN1+ furnace: Z8ES120C16LMPS1AHRI reference: 21247611915.208.10240002.40EPA 2478317 →
XAFC60HBCN1+ furnace: Z8ET100C20LMPS1AHRI reference: 21241808415.207.80252002.34EPA 2478362 →
XAHD60HBCN1+ furnace: Z8ES120C16SMPS1AHRI reference: 21241376615.208.10240002.40EPA 2479904 →
XAHD60GBCN1+ furnace: Z8ES100C16LMPS1AHRI reference: 21247835915.207.80254002.34EPA 2480334 →
XAFD60HBCN1+ furnace: Z8ES080C16SMPS1AHRI reference: 21241398615.207.80252002.34EPA 2481597 →
XAFC60HBCN1+ furnace: Z8ES080C16SMPS1AHRI reference: 21241400115.207.80252002.34EPA 2481608 →
XAFD60HBCN1+ furnace: Z8ES120C16LMPS1AHRI reference: 21247842215.207.80250002.34EPA 2482089 →
XAHD60GBCN1+ furnace: Z8ES100C16SMPS1AHRI reference: 21241733715.207.80254002.34EPA 2483488 →
XAFC60HBCN1+ furnace: Z8ET080C16LMPS1AHRI reference: 21241366615.207.80252002.34EPA 2483767 →
XAFC60HBCN1+ furnace: Z8ES100C20SMPS1AHRI reference: 21241384615.207.80252002.34EPA 2484949 →
XAFC60HBCN1+ furnace: Z8ES100C20LMPS1AHRI reference: 21248354915.207.80252002.34EPA 2485006 →
XAFD60HBCN1+ furnace: Z8ET100C20LMPS1AHRI reference: 21241806915.207.80252002.34EPA 2485277 →
XAFD60HBCN1+ furnace: Z8ES080C16LMPS1AHRI reference: 21247847115.207.80252002.34EPA 2485355 →
XAFC60HBCN1+ furnace: Z8ES080C16LMPS1AHRI reference: 21248651015.207.80252002.34EPA 2485373 →
XAFC60HBCN1+ furnace: Z8ES080C20SMPS1AHRI reference: 21241395615.207.80252002.32EPA 2485507 →