Fraser-Johnston / AIR-SOURCE HEAT PUMP

THF2B48T21

LX SERIES · source records, page 10

348 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity44,500–47,500BTU/h

Each efficiency range summarizes published EPA records for THF2B48T21. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 348 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16348 / 348
EER2 · BTU/Wh11–12348 / 348
HSPF2 · BTU/Wh7.8–8.1348 / 348
Cooling capacity · BTU/h44,500–47,500348 / 348
Heating capacity at 47°F / 8.3°C · BTU/h43,500–47,500348 / 348
Heating capacity at 17°F / −8.3°C · BTU/h29,200–34,200348 / 348
Heating capacity at 5°F / −15°C · BTU/h23,400–29,800348 / 348
COP at 5°F / −15°C2.22–2.84348 / 348
Equipment / loop typeHP - Split System348 / 348
Refrigerant / source-reported GWPR-410A (GWP:2088)348 / 348
Compressor stagingTwo-stage348 / 348
Connected capabilityNo348 / 348

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
XAHC60GBCN1+ furnace: TMLE100C20MP11AHRI reference: 21034827315.207.80240002.26EPA 3026248
XAHD60HBCN1+ furnace: TMLE100C20MP11AHRI reference: 21034871915.208.10254002.42EPA 3026251
XAFC60HBCN1+ furnace: TM8E100C20MP11AHRI reference: 21034873315.207.80238002.26EPA 3026256
XAFC60HBCN1+ furnace: TMLE100C20MP11AHRI reference: 21034873915.207.80238002.26EPA 3026257
XAFD60HBCN1+ furnace: TM8E100C20MP11AHRI reference: 21035625515.207.80238002.26EPA 3026278
XAFD60HBCN1+ furnace: TMLE100C20MP11AHRI reference: 21035626715.207.80238002.26EPA 3026280
XAFD60HBCN1+ furnace: TM8E100C16MP11AHRI reference: 21036010715.207.80238002.30EPA 3026288
XAFD60HBCN1+ furnace: TM8E080C20MP11AHRI reference: 21036093415.207.80238002.26EPA 3026292
XAFD60HBCN1+ furnace: TMLE080C20MP11AHRI reference: 21036094615.207.80238002.26EPA 3026300
XAFC60HBCN1+ furnace: TPLC080C16MP13AHRI reference: 21034577715.207.80234002.28EPA 3026497
XAFC60HBCN1+ furnace: TPLC100C16MP13AHRI reference: 21034578115.207.80234002.28EPA 3026500
XAHC60GBCN1+ furnace: TPLC120C20MP13AHRI reference: 21035463315.207.80242002.26EPA 3026551
XAHD60GBCN1+ furnace: TMLV100C16MP12AHRI reference: 21035466415.207.80236002.24EPA 3026558
XAHD60GBCN1+ furnace: TPLC080C16MP13AHRI reference: 21035466815.207.80236002.24EPA 3026571
XAHD60GBCN1+ furnace: TPLC100C16MP13AHRI reference: 21035467215.207.80236002.24EPA 3026572
XAFC60HBCN1+ furnace: TPLC120C20MP13AHRI reference: 21035785115.208.10238002.30EPA 3026729
XAFC60HBCN1+ furnace: TPLC100C20MP13AHRI reference: 21035784715.208.10238002.30EPA 3026731
XAFC60HBCN1+ furnace: TMLV120C20MP12AHRI reference: 21035784315.208.10238002.30EPA 3026735
XAHC60GBCN1+ furnace: TMLV100C16MP12AHRI reference: 21035956215.207.80238002.26EPA 3026751
XAHC60GBCN1+ furnace: TPLC080C16MP13AHRI reference: 21035956615.207.80238002.26EPA 3026754

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →