Fraser-Johnston / AIR-SOURCE HEAT PUMP

THF2B42T21

LX SERIES · source records, page 16

430 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity39,500–42,000BTU/h

Each efficiency range summarizes published EPA records for THF2B42T21. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 430 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16430 / 430
EER2 · BTU/Wh11.7–12430 / 430
HSPF2 · BTU/Wh7.8–8.1430 / 430
Cooling capacity · BTU/h39,500–42,000430 / 430
Heating capacity at 47°F / 8.3°C · BTU/h37,400–41,000430 / 430
Heating capacity at 17°F / −8.3°C · BTU/h24,200–26,600430 / 430
Heating capacity at 5°F / −15°C · BTU/h18,400–22,600430 / 430
COP at 5°F / −15°C1.98–2.42430 / 430
Equipment / loop typeHP - Split System430 / 430
Refrigerant / source-reported GWPR-410A (GWP:2088)430 / 430
Compressor stagingTwo-stage430 / 430
Connected capabilityNo430 / 430

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
XAHC48FBCN1+ furnace: TM9Y100C20MP11AHRI reference: 21034666015.208.10202002.08EPA 3984941 →
XAFD48FBCN1+ furnace: TM9Y100C16MP11AHRI reference: 21034667215.207.80196002.02EPA 3984946 →
XAHD48FBCN1+ furnace: TM9V080C16MP12AHRI reference: 21034672815.208.10193002.06EPA 3984971 →
XAHD48FBCN1+ furnace: TP9C080C16MP13AHRI reference: 21034673215.208.10193002.06EPA 3984976 →
XAFD48FBCN1+ furnace: TP9C120D20MP13AHRI reference: 21034381415.208.10196002.06EPA 3985285 →
XAFD48FBCN1+ furnace: TM9V120D20MP12AHRI reference: 21034381015.208.10196002.06EPA 3985287 →
XAFD48FBCN1+ furnace: TM9V100C20MP12AHRI reference: 21034383015.207.80196002.04EPA 3985293 →
XAFD48FBCN1+ furnace: TP9C100C20MP13AHRI reference: 21034383415.207.80196002.04EPA 3985300 →
XAHC48FBCN1+ furnace: TM9E080C20MP12AHRI reference: 21034384615.208.10198002.12EPA 3985418 →
XAHD48FBCN1+ furnace: TM8V080C16MP12AHRI reference: 21034390215.208.10204002.12EPA 3985420 →
XAFC48FBCN1+ furnace: TL9E100C20UH11AHRI reference: 21034405015.207.80199002.02EPA 3985465 →
XAFC48FXXN1+TXV+ furnace: TL9E100C20UH11AHRI reference: 21034404615.207.80199002.02EPA 3985467 →
XAFD48FBCN1+ furnace: TL8E100C20UH11AHRI reference: 21034407015.208.10196002.04EPA 3985478 →
XAFC48FXXN1+TXV+ furnace: TM9V100C20MP12AHRI reference: 21035172015.207.80198002.02EPA 3985552 →
XAFC48FXXN1+TXV+ furnace: TP9C100C20MP13AHRI reference: 21035172415.207.80198002.02EPA 3985553 →
XAFC48FBCN1+ furnace: TM9V100C20MP12AHRI reference: 21035173015.207.80198002.02EPA 3985556 →
XAFC48FBCN1+ furnace: TP9C100C20MP13AHRI reference: 21035173815.207.80198002.02EPA 3985561 →
XAHC48FBCN1+ furnace: TM9E100C20MP12AHRI reference: 21035175615.208.10198002.12EPA 3985569 →
XAFC48FXXN1+TXV+ furnace: TM9E100C20MP12AHRI reference: 21035176215.208.10196002.04EPA 3985571 →
XAFC48FBCN1+ furnace: TM9E100C20MP12AHRI reference: 21035176815.208.10196002.04EPA 3985577 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →