Fraser-Johnston / AIR-SOURCE HEAT PUMP

THF2B42T21

LX SERIES · source records, page 11

430 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity39,500–42,000BTU/h

Each efficiency range summarizes published EPA records for THF2B42T21. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 430 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16430 / 430
EER2 · BTU/Wh11.7–12430 / 430
HSPF2 · BTU/Wh7.8–8.1430 / 430
Cooling capacity · BTU/h39,500–42,000430 / 430
Heating capacity at 47°F / 8.3°C · BTU/h37,400–41,000430 / 430
Heating capacity at 17°F / −8.3°C · BTU/h24,200–26,600430 / 430
Heating capacity at 5°F / −15°C · BTU/h18,400–22,600430 / 430
COP at 5°F / −15°C1.98–2.42430 / 430
Equipment / loop typeHP - Split System430 / 430
Refrigerant / source-reported GWPR-410A (GWP:2088)430 / 430
Compressor stagingTwo-stage430 / 430
Connected capabilityNo430 / 430

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
XAHC48FBCN1+ furnace: Z9ET100C16SMPS1AHRI reference: 21241545415.207.80216002.32EPA 2477506 →
XAHC48FBCN1+ furnace: Z9ES100C16SMPS1AHRI reference: 21241567615.207.80222002.32EPA 2477602 →
XAFD48FBCN1+ furnace: Z8ES100C16LMPS1AHRI reference: 21248577215.208.10210002.22EPA 2478765 →
XAFD48FBCN1+ furnace: Z8ES120C20LMPS1AHRI reference: 21248574415.208.10212002.20EPA 2479479 →
XAFC48FXXN1+TXV+ furnace: Z8ES100B12LMPS1AHRI reference: 21248286815.207.80212002.20EPA 2479624 →
XAFD48FBCN1+ furnace: Z9ES120D20SMPS1AHRI reference: 21241558515.208.10208002.24EPA 2481571 →
XAFC48FBCN1+ furnace: Z8ES080B12SMPS1AHRI reference: 21241640715.208.10208002.20EPA 2481845 →
XAFC48FXXN1+TXV+ furnace: Z8ES080B12SMPS1AHRI reference: 21241640215.208.10208002.20EPA 2482062 →
XAFC48FBCN1+ furnace: Z8ES120C20LMPS1AHRI reference: 21248860515.207.80212002.20EPA 2482904 →
XAFC48FXXN1+TXV+ furnace: Z8ES100C16LMPS1AHRI reference: 21248863115.208.10210002.22EPA 2482911 →
XAFC48FBCN1+ furnace: Z8ES100C16LMPS1AHRI reference: 21248863815.208.10210002.22EPA 2482916 →
XAFC48FXXN1+TXV+ furnace: Z8ES120C20LMPS1AHRI reference: 21248859815.207.80212002.20EPA 2482922 →
XAFD48FBCN1+ furnace: Z8ES120C20SMPS1AHRI reference: 21241612215.208.10212002.20EPA 2483750 →
XAFC48FBCN1+ furnace: Z8ES120C20SMPS1AHRI reference: 21241613215.207.80212002.20EPA 2483757 →
XAFC48FXXN1+TXV+ furnace: Z8ES120C20SMPS1AHRI reference: 21241612715.207.80212002.20EPA 2484016 →
XAFC48FXXN1+TXV+ furnace: Z8ES080B12LMPS1AHRI reference: 21248867315.208.10208002.20EPA 2484175 →
XAFC48FBCN1+ furnace: Z8ES080B12LMPS1AHRI reference: 21248868015.208.10208002.20EPA 2484189 →
XAFC48FXXN1+TXV+ furnace: Z8ET080B12LMPS1AHRI reference: 21241606215.208.10208002.20EPA 2484291 →
XAFC48FBCN1+ furnace: Z8ET080B12LMPS1AHRI reference: 21241606715.208.10208002.20EPA 2484294 →
XAFD48FBCN1+ furnace: Z8ES100C16SMPS1AHRI reference: 21241625715.208.10210002.22EPA 2484617 →