Fraser-Johnston / AIR-SOURCE HEAT PUMP

THF2B36T21

LX SERIES · source records, page 8

215 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity33,400–36,000BTU/h

Each efficiency range summarizes published EPA records for THF2B36T21. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 215 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16215 / 215
EER2 · BTU/Wh11.7–12215 / 215
HSPF2 · BTU/Wh7.8–8.1215 / 215
Cooling capacity · BTU/h33,400–36,000215 / 215
Heating capacity at 47°F / 8.3°C · BTU/h32,600–34,800215 / 215
Heating capacity at 17°F / −8.3°C · BTU/h21,400–23,800215 / 215
Heating capacity at 5°F / −15°C · BTU/h16,500–20,000215 / 215
COP at 5°F / −15°C1.96–2.44215 / 215
Equipment / loop typeHP - Split System215 / 215
Refrigerant / source-reported GWPR-410A (GWP:2088)215 / 215
Compressor stagingTwo-stage215 / 215
Connected capabilityNo215 / 215

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
XAHD48FBCN1+ furnace: TM9V120D20MP12AHRI reference: 21035613715.207.80174002.10EPA 3987315 →
XAHD48FBCN1+ furnace: TP9C120D20MP13AHRI reference: 21035614115.207.80174002.10EPA 3987319 →
XAHD48FBCN1+ furnace: TM9E100C16MP12AHRI reference: 21035615315.207.80175002.08EPA 3987326 →
XAHC48FBCN1+ furnace: TM9E080B12MP12AHRI reference: 21035616515.207.80177002.04EPA 3987331 →
XAHC48FBCN1+ furnace: TM9V100C16MP12AHRI reference: 21035428515.207.80177002.08EPA 3987373 →
XAHC48FBCN1+ furnace: TP9C100C16MP13AHRI reference: 21035428915.207.80177002.08EPA 3987381 →
XAHC48FBCN1+ furnace: TL9E060B12UH11AHRI reference: 21035441815.207.80174002.06EPA 3987385 →
XAFD48FBCN1+JMVT20DC2N1AHRI reference: 21035442615.208.10176002.08EPA 3987389 →
XAFC48FBCN1+JMET12CS2N1AHRI reference: 21035444815.208.10176002.04EPA 3987394 →
JHETC42FBCS2N1AHRI reference: 21035446015.208.10176002.06EPA 3987396 →
XAHD48FBCN1+ furnace: TM8V100C16MP12AHRI reference: 21036219215.207.80174002.06EPA 3987414 →
XAHD48FBCN1+ furnace: TM8V080C16MP12AHRI reference: 21036219615.207.80174002.06EPA 3987416 →
XAHD48FBCN1+ furnace: TM9E080C16MP12AHRI reference: 21036210015.207.80175002.08EPA 3987698 →
JHVTC42FBCC2N1AHRI reference: 21035141915.208.10173002.08EPA 3987748 →
XAHC36DBCN1+JMET16CS2N1AHRI reference: 21035317715.207.80172002.12EPA 3987898 →
XAHB36DBCN1+JMVT12BC2N1AHRI reference: 21035316715.207.80172002.08EPA 3987922 →
XAFC36DBCN1+JMET12CS2N1AHRI reference: 21035318915.207.80168002.00EPA 3987950 →
XAHD48FBCN1+ furnace: TM9Y100C16MP11AHRI reference: 21035321315.207.80178002.04EPA 3987974 →
XAFC48FXXN1+TXV+ furnace: TL8E100C20UH11AHRI reference: 21035137715.207.80176002.04EPA 3988226 →
XAFC48FBCN1+ furnace: TL8E100C20UH11AHRI reference: 21035138115.207.80176002.04EPA 3988230 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →