Fraser-Johnston / AIR-SOURCE HEAT PUMP

THF2B30T21

LX SERIES · source records, page 10

246 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity28,400–30,600BTU/h

Each efficiency range summarizes published EPA records for THF2B30T21. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 246 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16246 / 246
EER2 · BTU/Wh11.7–12246 / 246
HSPF2 · BTU/Wh7.8–8.1246 / 246
Cooling capacity · BTU/h28,400–30,600246 / 246
Heating capacity at 47°F / 8.3°C · BTU/h27,000–29,200246 / 246
Heating capacity at 17°F / −8.3°C · BTU/h17,500–19,100246 / 246
Heating capacity at 5°F / −15°C · BTU/h13,600–18,600246 / 246
COP at 5°F / −15°C2.02–2.76246 / 246
Equipment / loop typeHP - Split System246 / 246
Refrigerant / source-reported GWPR-410A (GWP:2088)246 / 246
Compressor stagingTwo-stage246 / 246
Connected capabilityNo246 / 246

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
XAFC48FBAN1+JME12C2SN1AHRI reference: 21481113015.208.10158002.42EPA 3560502
XAFD48FBAN1+JME18D2SN1AHRI reference: 21481113415.208.10156002.40EPA 3560506
JHETB30DBAS2N1AHRI reference: 21033651415.207.80151002.28EPA 3984238
XAFC48FXXN1+TXV+ furnace: TM9E100C16MP12AHRI reference: 21034363215.208.10146002.12EPA 3984539
XAFC48FBAN1+ furnace: TM9E100C16MP12AHRI reference: 21034363815.208.10146002.12EPA 3984540
XAHC48FBAN1+ furnace: TM9E100C16MP12AHRI reference: 21035006815.207.80136002.04EPA 3985693
XAFB36DXXN1+TXV+ furnace: TL9E060B12UH11AHRI reference: 21035221715.207.80146002.12EPA 3985999
XAFB36DBAN1+ furnace: TL9E060B12UH11AHRI reference: 21035222115.207.80146002.12EPA 3986004
XAFC48FBAN1+ furnace: TM9Y100C16MP11AHRI reference: 21035252115.207.80142002.10EPA 3986076
XAFC48FXXN1+TXV+ furnace: TM9Y100C16MP11AHRI reference: 21035251515.207.80142002.10EPA 3986079
XAFB36DXXN1+TXV+ furnace: TM9V080B12MP12AHRI reference: 21035500515.207.80146002.10EPA 3986220
XAFB36DXXN1+TXV+ furnace: TP9C080B12MP13AHRI reference: 21035500915.207.80146002.10EPA 3986283
XAFB36DBAN1+ furnace: TM9V080B12MP12AHRI reference: 21035501515.207.80146002.10EPA 3986284
XAFB36DBAN1+ furnace: TP9C080B12MP13AHRI reference: 21035502315.207.80146002.10EPA 3986290
XAFC48FXXN1+TXV+ furnace: TP9C080B12MP13AHRI reference: 21035907115.207.80142002.08EPA 3986541
XAFC48FXXN1+TXV+ furnace: TM9V080B12MP12AHRI reference: 21035906715.207.80142002.08EPA 3986542
XAFC48FBAN1+ furnace: TM9V080B12MP12AHRI reference: 21035907715.207.80142002.08EPA 3986544
XAFC48FBAN1+ furnace: TP9C080B12MP13AHRI reference: 21035908515.207.80142002.08EPA 3986552
XAFC48FXXN1+TXV+ furnace: TM8Y100C16MP11AHRI reference: 21034650415.208.10142002.12EPA 3987153
XAFC48FXXN1+TXV+ furnace: TM8Y080C16MP11AHRI reference: 21034651215.208.10142002.12EPA 3987156

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.