Fraser-Johnston / AIR-SOURCE HEAT PUMP

THF2B24T21

LX SERIES · source records, page 8

165 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity22,800–24,200BTU/h

Each efficiency range summarizes published EPA records for THF2B24T21. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 165 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16165 / 165
EER2 · BTU/Wh11.7–12165 / 165
HSPF2 · BTU/Wh7.8–8.1165 / 165
Cooling capacity · BTU/h22,800–24,200165 / 165
Heating capacity at 47°F / 8.3°C · BTU/h20,600–22,800165 / 165
Heating capacity at 17°F / −8.3°C · BTU/h13,100–14,500165 / 165
Heating capacity at 5°F / −15°C · BTU/h9,600–12,000165 / 165
COP at 5°F / −15°C1.96–2.3165 / 165
Equipment / loop typeHP - Split System165 / 165
Refrigerant / source-reported GWPR-410A (GWP:2088)165 / 165
Compressor stagingTwo-stage165 / 165
Connected capabilityNo165 / 165

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
XAFB36DBAN1+ furnace: TL8E060A12UH11AHRI reference: 21035311115.207.80101002.06EPA 3987908
XAHC30CBAN1+ furnace: TM9Y100C16MP11AHRI reference: 21035365515.207.80109002.08EPA 3988238
XAHC30CBAN1+ furnace: TM9Y080B12MP11AHRI reference: 21035366715.207.80109002.08EPA 3988243
XAHC30CBAN1+ furnace: TM9Y080C16MP11AHRI reference: 21035062915.207.80109002.08EPA 3988527
XAFC30CBAN1+ furnace: TM9V080B12MP12AHRI reference: 21035064515.207.80107002.04EPA 3988532
XAFC30CBAN1+ furnace: TP9C080B12MP13AHRI reference: 21035064915.207.80107002.04EPA 3988536
XAFB30CBAN1+ furnace: TM9V080B12MP12AHRI reference: 21035066515.207.80107002.04EPA 3988541
XAFB30CBAN1+ furnace: TP9C080B12MP13AHRI reference: 21035067315.207.80107002.04EPA 3988544
XAHC36DBAN1+ furnace: TM9Y080B12MP11AHRI reference: 21034939615.207.80106002.12EPA 3988665
XAHC36DBAN1+ furnace: TM9E080C16MP12AHRI reference: 21034942815.207.80110002.18EPA 3988691
XAFB36DXXN1+TXV+ furnace: TM8Y060A12MP11AHRI reference: 21034948215.207.80102002.02EPA 3988694
XAFB36DBAN1+ furnace: TM8Y060A12MP11AHRI reference: 21034948815.207.80102002.02EPA 3988699
XAHB30CBAN1+JMVT12BC2N1AHRI reference: 21035583515.208.10108002.12EPA 3988969
XAHC36DBAN1+ furnace: TM9E100C16MP12AHRI reference: 21035589315.207.80108002.16EPA 3988978
XAHC30CBAN1+ furnace: TM9E100C16MP12AHRI reference: 21035367915.208.10111002.12EPA 3989061
XAFA30DBAN1+ furnace: Z8ET060A12LMPS1AHRI reference: 21259427415.207.80111002.22EPA 3991208
XAFB36DBAN1+ furnace: Z8ET060A12LMPS1AHRI reference: 21259442915.207.80111002.22EPA 3991288
XAFB36DXXN1+TXV+ furnace: Z8ET060A12LMPS1AHRI reference: 21259442415.207.80111002.22EPA 3991291
XAHB30CBAN1+ furnace: Z8ET060A12LMPS1AHRI reference: 21259475415.207.80113002.16EPA 3991504
XAHB36DBAN1+ furnace: Z8ET060A12LMPS1AHRI reference: 21259476415.207.80113002.26EPA 3991507

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →