Fraser-Johnston / AIR-SOURCE HEAT PUMP

HMH72B341

HMH7 · source records, page 40

784 published source records · source checked Sep 21, 2026

SEER2 range15.5–18.5BTU/Wh
HSPF2 range8.1–8.5BTU/Wh
Cooling capacity31,400–35,200BTU/h

Each efficiency range summarizes published EPA records for HMH72B341. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 784 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.5–18.5784 / 784
EER2 · BTU/Wh9–10.5784 / 784
HSPF2 · BTU/Wh8.1–8.5784 / 784
Cooling capacity · BTU/h31,400–35,200784 / 784
Heating capacity at 47°F / 8.3°C · BTU/h31,400–34,800784 / 784
Heating capacity at 17°F / −8.3°C · BTU/h24,600–27,000784 / 784
Heating capacity at 5°F / −15°C · BTU/h22,200–25,000784 / 784
COP at 5°F / −15°C1.8–2.18784 / 784
Equipment / loop typeHP - Split System784 / 784
Refrigerant / source-reported GWPR-410A (GWP:2088)784 / 784
Compressor stagingContinuously variable784 / 784
Connected capabilityNo784 / 784

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
XAHD48FXXN1+TXV+ furnace: TL9E100C20UH11Cold climate designationAHRI reference: 21138605315.508.50234002.04EPA 2483920 →
XAHC48FXXN1+TXV+ furnace: TL9E100C20UH11Cold climate designationAHRI reference: 21138608315.508.50234002.04EPA 2483927 →
XAFC48FXXN1+TXV+ furnace: TL9E100C20UH11Cold climate designationAHRI reference: 21138614215.508.50238002.08EPA 2484767 →
XAFC48FBCN1+ furnace: TL9E100C20UH11Cold climate designationAHRI reference: 21138615715.508.50238002.08EPA 2484771 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →